Combined System Load Factor
DS2000 and DSX-80/160 Combined System Load Factor Worksheet
Description
DSX-80/160 CPU Card
DSX-80/160 16ESIU Card
DS2000 16DSTU PCB
DSX-80/160 8SLIU Card
DSX-80/160 16SLIU Card
DS2000 4ASTU PCB
DS2000 8ASTU PCB
DSX-80/160 8COIU Card
DSX-80/160 16COIU Card
DS2000 4ATRU PCB
DS2000 8ATRU PCB
DSX-80/160 T1/PRI Card
Item 1: Load Type Totals
(Cannot exceed Item 2: Power Supply Capacity.)
If you have one power supply installed, the capacity is:
If you have two power supplies installed, the capacity is:
If you have three power supplies installed, the capacity is:
Notes:
DSX-80 can only have 1 power supply.
DSX-160 can have up to 3 power supplies. You cannot have more than two 16ESIU or 16DSTU Cards per power
supply, regardless of System Load Factor calculations.
Exceeding the allowed Load Type Total (Item 1) will cause the system's power supplies to automatically shut down
and/or cause erratic system operation.
The total of all station, line, and DSS Console ports cannot exceed 160.
6 ◆ Upgrading
Qty
5 VDC
Load
1
12
8
3
5
10
3
5
3
6
4
8
8
Item 2: Power Supply Capacity
Load Type
Total
Load
12
0
20
20
8
16
5
8
0
0
0
0
0
5 VDC = 40
40 VDC = 48
5 VDC = 80
40 VDC = 80
5 VDC = 120
40 VDC = 120
Upgrading DS2000 to DSX-80/160
40 VDC
Total
0