DIP Switch

DIP Switch Functions

The DM-D110 has one DIP switch. The functions of the DIP switch are
as follows:
DIP switch 1
DSW1 No.
Function
1-1
Data receive error
1-2
Data length
1-3
Parity on or off
1-4
Parity type
1-5
Change transmis-
1-6
sion speed
1-7
1-8
Self test selection (*)
(*)This function can select whether or not you perform self test when turning on the
power. See "Self Test" for details.
Transmission speed
SW1-5
ON
OFF
ON
OFF
ON
OFF
ON
OFF
32
ON
Ignored
7 bits
Parity
Even
See "Transmission speed."
Perform self
test
SW1-6
SW1-7
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Default setting
Displays "?"
OFF
8 bits
OFF
No parity
OFF
Odd
OFF
ON
OFF
ON
Do not per-
OFF
form
Transmission speed (bps)
2400
4800
9600
19200
38400
57600
115200
reserve