Fuel Consumption - GE HOME GENERATOR SYSTEMS Installation And Start-Up Manual

15,000 and 20,000 watt home generator system
Hide thumbs Also See for HOME GENERATOR SYSTEMS:
Table of Contents

Advertisement

Available languages

Available languages

fuel consumption

Estimated fuel supply requirements at half and full load for
natural gas and LP vapor fuels are shown here.
15kW
natural Gas
1/2 Load
Full Load
126 C
242 C
126,000 B
242,000 B
C = Cubic feet per hour
B = BTU's per hour
20kW
natural Gas
1/2 Load
Full Load
160 C
293 C
160,000 B
293,000 B
C = Cubic feet per hour
B = BTU's per hour
14
LP Vapor
1/2 Load
Full Load
56 C
108 C
140,000 B
270,000 B
LP Vapor
1/2 Load
Full Load
70.4 C
141.5 C
176,725 B
353,650 B
Physical
Properties
normal atmospheric
state
Boiling Point (in °f):
initial
end
heating Value:
Btu per gallon (net
LhV*)
Btu per gallon (gross**)
cubic feet (gas)
Density***
Weight†
octane number:
research
Motor
*
LHV (Low Heat Value) is the more realistic rating.
**
Gross heat value does not consider heat lost in the form of water during
combustion.
*** Density is given in "Cubic Feet of Gas per Gallon of Liquid".
Weight is given in "Pounds per Gallon of Liquid".
LP Vapor
natural
Gas
Gas
Gas
-44
-259
-44
-259
83,340
63,310
91,547
2,500
1,000
36.39
57.75
4.24
2.65
110+
110+
97

Hide quick links: