Single Sas Domain - HP 381513-B21 - Smart Array P800 Controller RAID Technology Brief

Redundancy in enterprise storage networks using dual domain sas configurations
Hide thumbs Also See for 381513-B21 - Smart Array P800 Controller RAID:
Table of Contents

Advertisement

archival, reference, and redundant highly-available applications. They are intended for use in an
environment where the drive workload is 40 percent or less.

Single SAS domain

There are many single points of failure in a single domain. Failure can originate from any controller,
expander device, JBOD or cable, as shown in Figure 1.
NOTE:
JBOD is the acronym for "Just a Bunch of Disks." It refers to a
group of hard disks, usually in an enclosure, that may or may not
be RAID configured.
Figure 1
Single domain SAS storage network
.
Server
Server
Controller
Controller
NOTE:
All figures in this technical brief using the "4 " notation indicate a
4-lane bundled path. There are 4 wires per lane, or 16 total wires
in a 4x cable.
IO Module
IO Module
4 4
Expander
Expander
Disk drive
Disk drive
Disk drive
Disk drive
Disk drive
Disk drive
JBOD
JBOD
3