LG ARUB115BT2 Service Manual
LG ARUB115BT2 Service Manual

LG ARUB115BT2 Service Manual

Arun series
Hide thumbs Also See for ARUB115BT2:

Advertisement

Internal Use Only
http://biz.lgservice.com
System
Outdoor Unit
R410A
SERVICE MANUAL R410A

(Exploded View)

MODEL : ARUN Series
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.

Advertisement

Table of Contents
loading

Summary of Contents for LG ARUB115BT2

  • Page 1: Exploded View

    Internal Use Only http://biz.lgservice.com System Outdoor Unit R410A SERVICE MANUAL R410A (Exploded View) MODEL : ARUN Series CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
  • Page 2: Table Of Contents

    2. Function ..................5 3. Dimensions ...................6 4. Piping Diagrams ................8 5. Wiring Diagrams .................13 6. Exploded View & Replacement Parts List........16 - 2 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 3: Specifications

    3. Due to our policy of innovation some specifications may be changed without prior notification 4. EEV : Electronic Expansion Valve - 3 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 4 3. Due to our policy of innovation some specifications may be changed without prior notification 4. EEV : Electronic Expansion Valve - 4 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 5: Function

    Option : Model name & price are different according to options, and assembled in factory with main unit Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separated package. - 5 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 6: Dimensions

    Dimensions Dimensions 160(6-5/16) - 6 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 7 Dimensions inch) (19-11/16 500mm side Suction side Front inch) 1500mm(59-1/16 160(6-5/16) - 7 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 8: Piping Diagrams

    Outdoor unit Service Valve Pressure sensor Sensor Strainer Pressure switch Solenoid ) To be used only for series Check valve - 8 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 9: Heating Operation

    Service Valve Pressure sensor Sensor Strai Pressure switch *( ) To be used only for series Solenoid Check valve - 9 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 10 Outdoor unit Service Valve Pressure sensor Sensor Strainer Pressure switch ) To be used only for series Solenoid Check valve - 10 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 11 Pressure sensor Pressure switch Accum Comp Comp Check valve Liquid Injection Sensor Solenoid Sub-Cooler Service Valve Strainer Outdoor unit - 11 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 12 Pressure sensor Pressure switch Accum Comp Comp Check valve Liquid Injection Sensor Solenoid Sub-Cooler Service Valve Strainer Outdoor unit - 12 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 13: Wiring Diagrams

    Wiring Diagrams 5. Wiring Diagrams 5.1 Heat Pump Model 5.1.1 3Ø 208/230V(ARUB076BT2, ARUB096BT2, ARUB115BT2) - 13 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 14: Main Pcb

    TEMP SENSOR) JIG1, JIG2 CN32 P-SENSOR(L) CN30 P-SENSOR(H) JIG POWER TERMINAL : AC 220V) (LOW PRESSURE SENSOR) (HIGH PRESSURE SENSOR) - 14 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 15: Lge Internal Use Only

    INV Onboarding Terminal CN05 COOLING FAN CN02 Main Communication Terminal to Main PCB CN01 FAN Communication Terminal to Fan PCB - 15 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 16: Exploded View & Replacement Parts List

    6. Exploded View Outdoor Unit UW1 Chassis (208/230V, ARUB076BT2/096BT2/115BT2) 268711C 268711A 268711B 649950A 566001 649950B W6631A W6200 W6640 W6631B - 16 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 17 Inv. discharge + HEX(Front) + HEX (back) Housing color : purple THERMISTOR 3 263230C Air + suction Pipe Housing color : black - 17 - Copyright ©2008 LG Electronics. Inc. All right reserved. LGE Internal Use Only Only for training and service purposes...
  • Page 18 JUNE, 2008 P/NO : MFL54555502...