Power Down; Extend The Hard Drive Drawer - HP 600 Maintenance And Service Manual

Hp storageworks 600 modular disk system maintenance and service guide
Hide thumbs Also See for 600:
Table of Contents

Advertisement

WARNING:
supply to the power enclosures, be sure that the electrical outlets are properly grounded (earthed).
CAUTION:
grounding procedures before beginning any installation procedure. Improper grounding can
result in ESD damage to electronic components. For more information, see "Preventing
electrostatic discharge (on page 23)."
CAUTION:
and/or the system. Use caution when performing other operations, such as hot-plug installations
or troubleshooting.
CAUTION:
regulating facility UPS device. This device protects the hardware from damage caused by power
surges and voltage spikes and keeps the system in operation during a power failure.

Power down

Be sure that the partner servers are the first units to be powered down and the last to be powered back up.
Taking this precaution ensures that the system and the OS are shut down in an orderly manner.
IMPORTANT:
To power down the MDS600:
Power down the partner servers. See the server documentation.
1.
Press and hold the Power On/Standby button for approximately 4 seconds. This action powers down
2.
both hard drive drawers.

Extend the hard drive drawer

Be sure all I/O bays contain either an I/O module or an I/O blank. The hard drive drawer does not
1.
open if I/O bays are empty.
Be sure the I/O modules or I/O blanks are fully seated and their handles are in the locked position. The
2.
hard drive drawer does not open if I/O modules or I/O blanks are not fully seated with their handles
in the locked position.
WARNING:
not extend the hard drive drawers beyond the supporting surface when the unit is not installed in
a rack.
WARNING:
one hard drive drawer is extended at a time.
WARNING:
adequately support the chassis during installation and removal. It is not secured to the rack frame
or mounted on rails.
A risk of electric shock from high leakage current exists. Before connecting the AC
Always be sure that equipment is properly grounded and that you follow proper
When performing non-hot-plug operations, you must power down the server blade
Protect the equipment from AC power fluctuations and temporary interruptions with a
If installing a hot-plug device, it is not necessary to power down the MDS600.
TIP HAZARD! To reduce the risk of personal injury or damage to the equipment, do
To reduce the risk of personal injury or damage to the equipment, ensure that only
To reduce the risk of personal injury or damage to the equipment, you must
Removal and replacement procedures 25