NOT ENOUGH OR NO HOT WATER
1. In a new installation,
the water
heater
may not be properly
connected.
Make
sure the cold water
supply
valve
is open.
Review
and check
piping
installation.
Make
sure
that the
cold water
line is connected
to the cold water
inlet to the
water
heater and the hot water
line to the hot water
outlet on
the water
heater.
2. Make
sure the electrical
supply
to your water
heater
is "ON".
3. Check
for loose or blown
fuses in your water
heater
circuit.
Circuit
breakers
weaken
with age and may not handle
their
rated
load and should
be replaced.
4. Make
certain
the disconnect
switch,
if used,
is in the "ON"
position.
5. Check
to see the electric
service
to your
house
has
not
been
interrupted.
If this is the case,
contact
the electric
company.
6.
Is the thermostat
set
to the desired
temperature?
See
"Temperature
Regulation"
section.
If you had experienced
very hot water
and now no hot water,
the problem
may
be due to the high temperature
shut
off
system.
See
"High
Temperature
Shut
Off System"
in the
"Troubleshooting"
section.
8.
During
very
cold weather,
the incoming
water
will also be
colder
and it will require
a longer
time to become
heated.
9. The hot water usage may exceed the capacity of the water heater.
If so, wait for water heater to recover after abnormal
demand.
Also examine
pipes and faucets for possible water leaks.
10.If
you can not determine
the problem,
then
call the Sears
Service
Department.
WATER
IS TOO
HOT
Adjust
the thermostat
to a lower setting.
See the "Temperature
Regulation"
section.