Hitachi CP-WX1100 Network Manual page 17

Network guide
Hide thumbs Also See for CP-WX1100:
Table of Contents

Advertisement

3.1 Confi guring and controlling the projector via a web browser (continued)
Item
SNMP Port
Port open
Trap address
SMTP Port
Port open
Network Bridge Port
Port Number
Daisy Chain Port
Port Number
Click [Apply] button to save the settings.
NOTE
• The new confi guration settings are activated after restarting the
network connection. When the confi guration settings are changed, you must
restart the network connection. You can restart the network connection by
clicking [Network Restart] on the main menu.
3. Management with Web browser software
Confi gures the SNMP port.
Click the [Enable] check box to use SNMP.
Confi gures the destination of the SNMP Trap in IP format.
• The address allows not only IP address but also domain
name if the valid DNS server is setup in the Network
Settings . The maximum length of host or domain name is up
to 255 characters.
Confi gures the SMTP port.
Click the [Enable] check box to use the e-mail function.
Confi gures the Bridge port number.
Input the port number. Any number between 1024 and 65535
can be set up. It is set to 9717 as the default setting.
Confi gures the Daisy Chain port number.
Input the port number. Any number between 1024 and 65535
can be set up. It is set to 9718 as the default setting.
Description
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-x10000Cp-wx11000Cp-sx12000

Table of Contents