HP Integrity rx7620 Datasheet
HP Integrity rx7620 Datasheet

HP Integrity rx7620 Datasheet

Hp insight management wbem providers on integrity servers data sheet
Hide thumbs Also See for Integrity rx7620:
Table of Contents

Advertisement

HP Insight Management WBEM Providers for
Windows on Integrity Servers
Data Sheet
Part number
5992-4515
First Edition September 2008

Advertisement

Table of Contents
loading

Summary of Contents for HP Integrity rx7620

  • Page 1 HP Insight Management WBEM Providers for Windows on Integrity Servers Data Sheet Part number 5992-4515 First Edition September 2008...
  • Page 2 Legal notices © Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
  • Page 3: Table Of Contents

    Contents Overview........................... 13 Base server ..........................14 Overview............................ 14 Use cases ........................... 14 Class implementations ........................14 2-3-1 HP_WinComputerSystem ....................14 2-3-2 HP_ComputerSystemChassis ....................17 2-3-3 HP_ComputerSystemPackage....................18 2-3-4 HP_PowerManagementService..................... 18 2-3-5 HP_PowerManagementCapabilities ..................19 2-3-6 HP_AssociatedPowerManagementService ................20 2-3-7 HP_PowerManagementElementCapabilities ................
  • Page 4 4-3-3 HP_PowerRedundancySet....................46 4-3-4 HP_MemberOfPowerRedundancy..................46 4-3-5 HP_HostedPowerRedundancySet ..................47 4-3-6 HP_MemberOfPowerCollection .................... 47 4-3-7 HP_HostedPowerCollection....................47 4-3-8 HP_SystemPowerSupply ...................... 48 4-3-9 HP_Location ........................48 4-3-10 HP_ElementLocation......................48 4-3-11 CIM_ConfigurationCapacity ....................49 4-3-12 CIM_ElementCapacity ......................49 Supported indications........................50 System fan ..........................51 Overview............................
  • Page 5 7-3-11 HP_RealizesMemoryModule ....................76 7-3-12 HP_ MemoryModuleSlot...................... 76 7-3-13 HP_MemoryBoardSlot......................77 7-3-14 HP_MemoryModuleInSlot ....................78 7-3-15 HP_MemoryBoardInSlot ...................... 78 7-3-16 HP_ MemoryModuleSlotOnBoard..................79 7-3-17 HP_MemoryModuleSlotLocation ................... 79 7-3-18 HP_MemoryBoardSlotLocation ..................... 80 7-3-19 HP_MemoryModuleSlotElementLocation ................81 7-3-20 HP_MemoryBoardSlotElementLocation .................. 82 7-3-21 HP_SystemMemoryModuleSlot .....................
  • Page 6 11-2 Use cases........................106 11-3 Class implementations ...................... 106 11-3-1 HP_BladeEnclosureCS....................... 106 11-3-2 HP_BladeEnclosureCollection..................... 108 11-3-3 HP_BladeSystemComponent ....................109 11-3-4 HP_MemberOfBladeEnclosureCollection ................109 11-3-5 HP_BladeEnclosureGroupHostedCollection ................110 11-3-6 CIM_SoftwareIdentity ....................... 110 11-3-7 CIM_ElementSoftwareIdentity..................... 111 11-3-8 CIM_InstalledSoftwareIdentity .................... 111 11-4 Supported indications ....................... 112 Ethernet Teaming ........................
  • Page 7 13-3-11 HPSA_StorageEnclosureProcessor................167 13-3-12 HPSA_PortController ....................168 13-3-13 HPSA_DAPort ......................169 13-3-14 HPSA_SPIPort ......................170 13-3-15 HPSA_Firmware ..................... 171 13-3-16 HPSA_EnclosureFirmware..................171 13-3-17 HPSA_PrimordialPool....................172 13-3-18 HPSA_StoragePool ....................173 13-3-19 HPSA_MediaAccessStatData ................... 173 13-3-20 HPSA_StorageSetting....................174 13-3-21 HPSA_DriveCage ....................175 13-3-22 HPSA_SCSIProtocolEndpoint..................
  • Page 8 13-3-65 HPSA_StorageEnclosureProcessorEnclosureFirmware (Association)........ 192 13-3-66 HPSA_DiskDriveDiskDriveFirmware (Association)............193 13-3-67 HPSA_DiskDriveStorageExtent (Association)............... 193 13-3-68 HPSA_DiskPhysicalPackageDiskDrive (Association) ............. 193 13-3-69 HPSA_StoragePoolStorageVolume (Association) ............193 13-3-70 HPSA_PrimordialPoolStoragePool (Association) ............193 13-3-71 HPSA_SpareExtentStorageExtent (Association) ............194 13-3-72 HPSA_SpareExtentStorageRedundancySet (Association) ..........194 13-3-73 HPSA_StorageExtentStorageVolume (Association)............194 13-3-74 HPSA_DAPortSCSIProtocolEndpoint (Association) ............
  • Page 9 14-3-26 HPFCHBA_SoftwareIdentityDrvPortController.............. 268 14-3-27 HPFCHBA_PortControllerFirmwareIdentityFW............. 269 14-3-28 HPFCHBA_PortControllerFirmwareIdentityBIOS............269 14-3-29 HPFCHBA_ProductPhysicalComponent ..............270 14-3-30 HPFCHBA_SystemPackaging ................... 270 14-3-31 HPFCHBA_ConcreteIdentity ..................270 14-3-32 HPFCHBA_GroupHostedCollection ................271 14-3-33 HPFCHBA_FCPortGroupSystemSpecific ..............271 14-3-34 HPFCHBA_Location ....................271 14-3-35 HPFCHBA_PhysicalElementLocation ................272 14-4 Supported indications ....................... 272 SAS HBA..........................
  • Page 10 15-3-39 HPSAS_ArraySystemSCSIProtocolController (Association) ..........298 15-3-40 HPSAS_ArraySystemPortController (Association)............298 15-3-41 HPSAS_ArraySystemDiskDrive (Association)............... 298 15-3-42 HPSAS_ArraySystemStorageVolume (Association) ............299 15-3-43 HPSAS_ArraySystemStorageExtent (Association)............299 15-3-44 HPSAS_ArraySystemDAPort (Association) ..............299 15-3-45 HPSAS_ArraySystemPrimordialPool (Association) ............299 15-3-46 HPSAS_ArraySystemPrimordialPoolNoRaid (Association)..........300 15-3-47 HPSAS_ArraySystemStoragePool (Association) ............300 15-3-48 HPSAS_ComputerSystemArraySystem (Association) ............
  • Page 11 16-3-18 HPSCSI_DASCSIProtocolEndpoint................354 16-3-19 HPSCSI_HBASCSIProtocolController ................. 355 16-3-20 HPSCSI_HBAGroupCollection .................. 356 16-3-21 HPSCSI_StorageEnclosureLocation................356 16-3-22 HPSCSI_DriveCageLocation..................357 16-3-23 HPSCSI_HBALocation ..................... 357 16-3-24 HPSCSI_DiskDriveLocation..................358 16-3-25 HPSCSI_HBAProduct....................358 16-3-26 HPSCSI_HBAComputerSystemStorageEnclosureProcessor (Association) ......359 16-3-27 HPSCSI_HBAComputerSystemSCSIProtocolController (Association) ....... 359 16-3-28 HPSCSI_HBAComputerSystemPortController (Association)..........359 16-3-29 HPSCSI_HBAComputerSystemDiskDrive (Association)..........
  • Page 12 18-2 Use cases........................406 18-3 Class implementations ...................... 406 18-3-1 CIM_RegisteredProfile....................... 406 18-3-2 HP_RegisteredProfile......................408 18-3-3 HP_ExtendsProfile......................409 18-3-4 HP_ReferencedProfile......................410 18-3-5 HP_ElementConformsToProfile.................... 410 18-4 Supported indications ....................... 410 For more information......................... 411 Contents 12...
  • Page 13: Overview

    Overview The HP Insight Management WBEM Providers supply system management data through the Windows® Management Instrumentation (WMI) framework for HP Integrity server platforms and options. These providers implement the profiles and data described in this document. Use of the providers requires Windows Server® 2003 or Windows Server 2008, and WMI. 0BOverview 13...
  • Page 14: Base Server

    Base server Overview The following profiles are implemented, and files are installed by this provider. Table 2-1 Overview Implemented Profiles • HP Base Server Profile (P00105) • HP Base Server Physical Asset Profile (P00114) • DMTF Power State Management Profile (DSP1027) •...
  • Page 15 Table 2-2 Class: HP_WinComputerSystem Properties ElementName Computer system DNS name returned by Windows API GetComputerSystemName() CIM_ManagedSystemElement OperationalStatus OperationalStatus[0] contains the computer system consolidated status and indicates the worst status of connected subsystems. OperationalStatus[0] contains one of the following: • 0 (Unknown) •...
  • Page 16 Table 2-2 Class: HP_WinComputerSystem Properties OtherIdentifyingInfo • OtherIdentifyingInfo[0]: HPQ:<ProductID_String> where <ProductID_String> is HP_ComputerSystemChassis.ProductID. • OtherIdentifyingInfo[1]: CIM:<UUID_String> where <UUID_String> is the computer system UUID string. • OtherIdentifyingInfo[2]: CIM:<Model_String>:<Serial Number String> where <Model_String> is the computer system model string and <Serial Number String> is the computer system serial number string.
  • Page 17: Hp_Computersystemchassis

    Table 2-2 Class: HP_WinComputerSystem Properties LocationIndicator State of the computer system Unit Identifier (UID) LED (writable property): • 0 (Unknown) • 2 (On) • 3 (Off) • 5 (Alternating) HP_WinComputerSystem HP_ComputerSystemChassis 2-3-2 HP_ComputerSystemChassis extends the class CIM_ComputerSystemChassis to model the physical system chassis.
  • Page 18: Hp_Computersystempackage

    Table 2-3 Class: HP_ComputerSystemChassis Property name Property implementation ProductID Computer system product ID string (for example, 123456-123) VirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment VirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_ComputerSystemPackage 2-3-3...
  • Page 19: Hp_Powermanagementcapabilities

    Table 2-5 Class: HP_PowerManagementService Properties Property name Property implementation CIM_ManagedSystemElement OperationalStatus 2 (OK) StatusDescriptions StatusDescriptions[0] contains the following corresponding to OperationalStatus[0]: Power Management Service is OK HealthState 5 (OK) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_Service SystemName...
  • Page 20: Hp_Associatedpowermanagementservice

    Table 2-6 Class: HP_PowerManagementCapabilities Properties Property name Property implementation CIM_PowerManagmentCapabilities PowerCapabilities • PowerCapabilities[0]: 3 (Power State Settable) • PowerCapabilities[1]: 4 (Power Cycling Supported) PowerChangeCapabilities • PowerChangeCapabilities[0]: 3 (Power State Settable) • PowerChangeCapabilities[1]: 4 (Power Cycling Supported) PowerStatesSupported • PowerStatesSupported[0]: 0 (On) •...
  • Page 21: Hp_Hostedpowermanagementservice

    Table 2-8 Class: HP_PowerManagementElementCapabilities Property name Property implementation CIM_ElementCapabilities HP_PowerManagementElementCapabilities ManagedElement ref: HP_PowerManagementService Capabilities ref: HP_PowerManagementCapabilities HP_HostedPowerManagementService 2-3-8 HP_HostedPowerManagementService extends the class CIM_HostedService and associates the HP_ComputerSystem instance and the HP_PowerManagementService instance. Only one instance of HP_HostedPowerManagementService is instantiated on an Integrity server. The following properties are implemented.
  • Page 22 Table 2-10 Class: HP_SystemROMFirmware Property name Property implementation Description System ROM Firmware-<family_code> (<state>), where <family_code> is the system ROM family code and <state> is either Active or Redundant Examples: • System ROM Firmware-P31 (Active) • System ROM Firmware-P31 (Redundant) ElementName <family_code>, where <family_code>...
  • Page 23: Hp_Systemromelementfirmwareidentity

    Table 2-10 Class: HP_SystemROMFirmware Property name Property implementation ReleaseDate YYYYMMDD******.**********, where YYYY is the four digit year of the release date, MM is the two digit month of the release date, and DD is the two digit day. HP_SystemROMFirmware HP_SystemROMElementFirmwareIdentity 2-3-10 HP_SystemROMElementFirmwareIdentity extends the class CIM_ElementSoftwareIdentity and associates the HP_ComputerSystem instance and HP_SystemROMFirmware instances.
  • Page 24: Supported Indications

    Table 2-12 Class: HP_SystemROMInstalledFirmwareIdentity Property name Property implementation HP_SystemROMInstalledFirmwareIdentity InstalledSoftware ref: HP_SystemROMFirmware System ref: HP_ComputerSystem Supported indications There are no indications specific to the base server profile implementation. 1BBase server 24...
  • Page 25: Use Cases

    Overview The following profiles are implemented, and the following files are installed by this provider. Table 3-1 Overview Implemented Profiles • HP CPU Profile (P00106) • HP CPU Consolidated Status Profile (P00107) • HP CPU Physical Asset Profile (P00108) • HP Location Profile (P00124) Provider Installation Files •...
  • Page 26 Table 3-2 Class: HP_Processor Properties Property name Property implementation Description <processor brand string> (x86 Family x Model y Stepping z), where <processor brand string> is the processor brand string, x is the processor family number, y is the processor model number and z is the processor stepping number Example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7)
  • Page 27: Hp_Processorcapabilities

    Table 3-2 Class: HP_Processor Properties Property name Property implementation EnabledDefault 2 (Enabled) CIM_LogicalDevice SystemCreationClassName HP_WinComputerSystem SystemName Computer system name from Windows API GetComputerSystemName() CreationClassName HP_Processor DeviceID Proc n, where n is the processor number CIM_Processor CPUStatus • 1 (CPU Enabled) •...
  • Page 28: Hp_Processorcore

    Table 3-3 Class: HP_ProcessorCapabilities Property name Property implementation InstanceID HPQ:HP_ProcessorCapabilities:n, where n is a unique, sequentially-assigned number in the form 001, 002, and so on. ElementName Processor Capabilities – x86 CIM_EnabledLogicalElementCapabilities ElementNameEditSupported 0 (False) RequestedStatesSupported None CIM_ProcessorCapabilities NumberOfProcessorCores Number of processor cores (for example, 1, 2, 4) NumberOfHardwareThreads Number of hardware threads (for example, 1, 2) HP_ProcessorCapabilities...
  • Page 29 Table 3-4 Class: HP_ProcessorCore Property name Property implementation OperationalStatus • 0 (Unknown) • 2 (OK), when CPU is enabled and operational • 5 (Predictive Failure), when IML error information is logged for this CPU • 6 (Error), when CPU is disabled through POST error •...
  • Page 30: Hp_Hardwarethread

    Table 3-4 Class: HP_ProcessorCore Property name Property implementation Characteristics • For x86 processors: Characteristics[0]: 3 (32-bit Capable) • For x64 processors: ○ Characteristics[0]: 3 (32-bit Capable) ○ Characteristics[1]: 2 (64-bit Capable) HP_ProcessorCore Bootstrap • False • True HP_HardwareThread 3-3-4 HP_HardwareThread extends the class CIM_HardwareThread to model the hardware threads. The following properties are implemented.
  • Page 31: Hp_Processorcachememory

    Table 3-5 Class: HP_HardwareThread Property name Property implementation OperationalStatus • 0 (Unknown) • 2 (OK), when CPU is enabled and operational • 5 (Predictive Failure), when IML error information is logged for this CPU • 6 (Error), when CPU is disabled through POST error •...
  • Page 32 Table 3-6 Class: HP_ProcessorcacheMemory Property name Property implementation CIM_ManagedElement Caption One of the following: • Level x Data Cache, where x is the cache level number • Level x Instruction Cache, where x is the cache level number • Level x Unified Cache, where x is the cache level number Examples: •...
  • Page 33 Table 3-6 Class: HP_ProcessorcacheMemory Property name Property implementation StatusDescriptions StatusDescriptions[0] text per OperationalStatus[0]: • Processor-module status unknown. • Processor-module status OK • Processor-module is degraded, it is predicted to Fail • Processor-module in Slot: a Socket: b disabled by BIOS (POST Error), where a is the slot number and b is the socket number •...
  • Page 34: Hp_Systemprocessor

    Table 3-6 Class: HP_ProcessorcacheMemory Property name Property implementation NumberOfBlocks Number of blocks in this cache (for example, 8192 or 524288) Primordial 0 (False) CIM_Memory HP_CacheMemory HP_ProcessorCacheMemory HP_SystemProcessor 3-3-6 HP_SystemProcessor extends the class CIM_SystemDevice and associates HP_ComputerSystem and HP_Processor instances. The following properties are implemented. Table 3-7 Class: HP_SystemProcessor Property name...
  • Page 35: Hp_Processorcorecomponent

    HP_ProcessorCoreComponent 3-3-8 HP_ProcessorCoreComponent extends the class CIM_ConcreteComponent and associates an HP_Processor instance with HP_ProcessorCore instances. The following properties are implemented. Table 3-9 Class: HP_ProcessorCoreComponent Property name Property implementation CIM_Component CIM_ConcreteComponent HP_ProcessorCoreComponent GroupComponent ref: HP_Processor PartComponent ref: HP_ProcessorCore HP_HWThreadComponent 3-3-9 HP_HWThreadComponent extends the class CIM_ConcreteComponent and associates an HP_ProcessorCore instance with HP_HardwareThread instances.
  • Page 36 Table 3-11 Class: HP_AssociatedProcessorCacheMemory Property name Property implementation CIM_AssociatedMemory CIM_AssociatedCacheMemory Level • 0 (Unknown) • 1 (Other) • 2 (Not Applicable) • 3 (Primary) • 4 (Secondary) • 5 (Tertiary) WritePolicy • 0 (Unknown) • 1 (Other) • 2 (Write Back) •...
  • Page 37: Hp_Processorcollection

    HP_ProcessorCollection 3-3-11 HP_ProcessorCollection extends the class HP_GroupSystemSpecificCollection. The following properties are implemented. Table 3-12 Class: HP_ProcessorCollection Property name Property implementation CIM_ManagedElement Description A collection of processor packages with group aggregate status ElementName HP_ProcessorCollection CIM_Collection CIM_SystemSpecificCollection InstanceID HPQ:HP_ProcessorCollection:000 HP_GroupSystemSpecificCollection Caption Processor Package Collection GroupOperationalStatus •...
  • Page 38: Hp_Physicalmemberofprocessorcollection

    Table 3-13 Class: HP_ProcessorGroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_ProcessorGroupHostedCollection Antecedent ref: HP_ComputerSystem Dependent ref: HP_ProcessorCollection HP_PhysicalMemberOfProcessorCollection 3-3-13 HP_PhysicalMemberOfProcessorCollection extends the class CIM_MemberOfCollection and associates the HP_ProcessorCollection instance with an HP_ProcessorChip instance. The following properties are implemented. Table 3-14 Class: HP_PhysicalMemberOfProcessorCollection Property name...
  • Page 39 Table 3-15 Class: HP_ProcessorChip Properties Property name Property implementation OperationalStatus • 0 (Unknown) • 2 (OK), when CPU is enabled and operational • 5 (Predictive Failure), when IML error information is logged for this CPU • 6 (Error), when CPU is disabled through POST error •...
  • Page 40: Hp_Realizesprocessor

    Table 3-15 Class: HP_ProcessorChip Properties Property name Property implementation Manufacturer Processor manufacturer string from SMBIOS (for example, Intel or AMD) Model Model y, where y is the processor model number Version Model y Stepping z, where y is the processor model number, and z is the processor stepping number PoweredOn •...
  • Page 41: Hp_Processorlocation

    Table 3-17 Class: SystemPhysicalProcessor Property name Property implementation CIM_Component CIM_Container HP_SystemPhysicalProcessor GroupComponent ref: HP_ComputerSystemChassis PartComponent ref: HP_ProcessorChip HP_ProcessorLocation 3-3-17 HP_ProcessorLocation implements the class HP_Location that extends the class CIM_Location. The following properties are implemented. Table 3-18 Class: HP_ProcessorLocation Property name Property implementation CIM_ManagedElement Caption...
  • Page 42: Hp_Processorelementlocation

    Table 3-18 Class: HP_ProcessorLocation Property name Property implementation LocationInformation • LocationInformation[0]: the socket number • LocationInformation[1]: the cabinet number (cellular systems only) • LocationInformation[2]: the cell number (cellular systems only) LocationInfoDesc • LocationInfoDesc[0]: 4 (Socket), indicates that the first element of the LocationInformation array contains the socket number •...
  • Page 43: System Power Supply

    System Power Supply Overview This provider implements the HP Power Supply profile to model power supplies in Integrity systems. The following profiles are implemented, and the following files are installed by this provider. Table 4-1 Overview Implemented Profiles • HP Power Supply Profile 1.0 •...
  • Page 44: Hp_Powercollection

    Table 4-2 Class: HP_PowerSupply Property name Property implementation Description Power Supply n provides power for PowerSupplyType. StatusDescription, where n represents the number of the power supply instance, PowerSupplyType represents the corresponding string value of the PowerSupplyType enumeration, and StatusDescription represents the value of StatusDescriptions[0] ElementName Power Supply n, where n represents the number of the...
  • Page 45 Table 4-3 Class: HP_PowerCollection Property name Property implementation CIM_ManagedElement Caption Power Collection Description This is a collection of all devices including power supplies that provide power. GroupStatusDescription. GroupStatusDescription represents the value of the GroupStatusDescriptions[0] property ElementName Power Collection CIM_SystemSpecificCollection InstanceID Unique identifier for this power collection instance HP_GroupSystemSpecificCollection GroupOperationalStatus[0]...
  • Page 46: Hp_Powerredundancyset

    HP_PowerRedundancySet 4-3-3 HP_PowerRedundancySet is used to model power supply redundancy sets on Integrity servers. The Windows implementation class is HP_WinPowerRedundancySet. Table 4-4 Class: HP_PowerRedundancySet Property name Property implementation CIM_ManagedElement Caption Power Redundancy Set n, where n represents the number of the redundancy set instance Description Power Redundancy Set n is collection of fault tolerant power supplies that provide redundant power.
  • Page 47: Hp_Hostedpowerredundancyset

    Table 4-5 Class: HP_MemberOfPowerRedundancy Property name Property implementation Collection References HP_PowerRedundancySet Member References HP_PowerSupply HP_HostedPowerRedundancySet 4-3-5 HP_HostedPowerRedundancySet is used to represent an association between HP_PowerRedundancySet and the computer system that contains this redundancy set. The Windows implementation class is HP_WinHostedPowerRedundancySet. Table 4-6 Class:HP_HostedPowerRedundancySet Property name...
  • Page 48: Hp_Systempowersupply

    HP_SystemPowerSupply 4-3-8 HP_SystemPowerSupply is used to represent an association between HP_PowerSupply and the computer system that contains this power supply. The Windows implementation class is HP_WinSystemPowerSupply. Table 4-9 Class: HP_SystemPowerSupply Property name Property implementation GroupComponent References HP_ComputerSystem PartComponent References HP_PowerSupply HP_Location 4-3-9 HP_Location is used to model power supply locations on Integrity servers.
  • Page 49: Cim_Configurationcapacity

    Table 4-11 Class: HP_ElementLocation Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location CIM_ConfigurationCapacity 4-3-11 CIM_ConfigurationCapacity is used to model power supply configuration capacity on Integrity Servers. The Windows implementation class is HP_WinPowerSupplyConfigurationCapacity. There is one instance of this class on systems modeling power supply configuration capacity. Table 4-12 Class: CIM_ConfigurationCapacity Property name...
  • Page 50: Supported Indications

    Supported indications There are no indications specific to the system power supply profile implementation. 3BSystem Power Supply 50...
  • Page 51: System Fan

    System fan Overview This provider implements the profiles listed to support fans installed in Integrity servers. The following profiles are implemented, and the following files are installed by this provider. Table 5-1 Overview Implemented Profiles • HP Fan Profile 1.0 •...
  • Page 52 Table 5-2 Class: HP_Fan Property name Property implementation Description Fan n provides cooling for fantype. statusdescription. n represents the number of the fan instance, fantype represents the corresponding string value of the FanType enumeration and statusdescription represents the value of StatusDescriptions[0] ElementName Fan n, where n represents the number of the fan instance.
  • Page 53: Hp_Coolingcollection

    HP_CoolingCollection 5-3-2 HP_CoolingCollection is used to model fan collections on Integrity Servers. The Windows implementation class is HP_WinCoolingCollection. There is one instance of this class on systems modeling fans. Table 5-3 Class: HP_CoolingCollection Property name Property implementation CIM_ManagedElement Caption Cooling Collection Description This is a collection of all devices including fans that provide cooling.
  • Page 54: Hp_Coolingredundancyset

    HP_CoolingRedundancySet 5-3-3 HP_CoolingRedundancySet is used to model fan redundancy sets on Integrity servers. The Windows implementation class is HP_WinCoolingRedundancySet. Table 5-4 Class: HP_CoolingRedundancySet Property name Property implementation CIM_ManagedElement Caption Cooling Redundancy Set n n represents the number of the redundancy set instance Description Cooling Redundancy Set n is collection of fault tolerant fans that provide redundant cooling.
  • Page 55: Hp_Hostedcoolingredundancyset

    Table 5-5 Class: HP_MemberOfCoolingRedundancy Property name Property implementation Collection References HP_CoolingRedundancySet Member References HP_Fan HP_HostedCoolingRedundancySet 5-3-5 HP_HostedCoolingRedundancySet is used to represent an association between HP_CoolingRedundancySet and the computer system that contains this redundancy set. The Windows implementation class is HP_WinHostedCoolingRedundancySet. Table 5-6 Class: HP_HostedCoolingRedundancySet Property name...
  • Page 56: Hp_Systemfan

    HP_SystemFan 5-3-8 HP_SystemFan is used to represent an association between HP_Fan and the computer system that contains this fan. The Windows implementation class is HP_WinSystemFan. Table 5-9 Class: HP_SystemFan Property name Property implementation GroupComponent References HP_ComputerSystem PartComponent References HP_Fan HP_Location 5-3-9 HP_Location is used to model fan locations on Integrity servers.
  • Page 57: Cim_Elementcapacity

    Table 5-11 Class: HP_ElementLocation Property name Property implementation PhysicalLocation References CIM_Location CIM_ConfigurationCapacity 5-3-11 CIM_ConfigurationCapacity is used to model fan configuration capacity on Integrity Servers. The Windows implementation class is HP_WinFanConfigurationCapacity. There is one instance of this class on systems modeling fan configuration capacity. Table 5-12 Class: CIM_ConfigurationCapacity Property name...
  • Page 58: Supported Indications

    Supported indications There are no indications specific to the system fan profile implementation. 4BSystem fan 58...
  • Page 59: System Temperature Sensor

    System Temperature Sensor Overview This provider implements the HP Sensor Profile to model temperature sensors in Integrity servers. The following profiles are implemented, and the following files are installed by this provider. Table 6-1 Overiew Implemented Profiles • HP Sensor Profile 1.0 Provider Installation Files •...
  • Page 60 Table 6-2 Class: HP_NumericSensor Property name Property implementation Description Temperature Sensor n detects for NumericSensorType. StatusDescription. n represents the number of the temperature sensor instance, NumericSensorType represents the value of NumericSensorType and StatusDescription represents the value of StatusDescriptions[0] ElementName Temperature Sensor n, where n represents the number of the temperature sensor instance.
  • Page 61 Table 6-2 Class: HP_NumericSensor Property name Property implementation SensorType 2 (Temperature) CurrentState • Normal—if OperationalStatus[0] is 2 (OK) • Critical—if OperationalStatus[0] is 6 (Error) PossibleStates Array can contain any of the following values: • PossibleStates[9] = Normal • PossibleStates[3] = Critical CIM_NumericSensor CurrentReading Current reading of temperature sensor...
  • Page 62: Hp_Sensorcollection

    HP_SensorCollection 6-3-2 HP_SensorCollection is used to model temperature sensor collections on Integrity servers. The Windows implementation class is HP_WinSensorCollection. There is one instance of this class on systems modeling sensors. Table 6-3 Class: HP_SensorCollection Property name Property implementation CIM_ManagedElement Caption Temperature Sensor Collection Description This is a collection of temperature sensors.
  • Page 63: Hp_Hostedsensorcollection

    Table 6-4 Class: HP_MemberOfSensorCollection Property name Property implementation Collection References HP_SensorCollection Member References HP_NumericSensor HP_HostedSensorCollection 6-3-4 HP_HostedSensorCollection is used to represent an association between HP_SensorCollection and the computer system that contains the collection. The Windows implementation class is HP_Win HostedSensorCollection. Table 6-5 Class: HP_HostedSensorCollection Property name...
  • Page 64: System Memory

    System memory Overview This provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory in Integrity systems. The following profiles are implemented, and the following files are installed by this provider. Table 7-1 Overview Implemented Profiles •...
  • Page 65 Table 7-2 Class: HP_Memory Property name Property implementation Description Logical system memory ElementName System Memory CIM_ManagedSystemElement OperationalStatus Enumerator indicating the logical system memory operational status. The status represents the ‘worst-of’ algorithm for all OperationalStatus[0] values reported by physical memory modules in HP_MemoryModule instances.
  • Page 66: Hp_Systemmemory

    Table 7-2 Class: HP_Memory Property name Property implementation CIM_StorageExtent Access 3 (Read/Write Supported) BlockSize 1 (byte) ConsumableBlocks Capacity in bytes NumberOfBlocks Capacity in bytes Primordial True Purpose System Memory SequentialAccess False CIM_Memory StartingAddress Beginning address of the memory in kilobytes EndingAddress Ending address of the memory in kilobytes Volatile...
  • Page 67 Table 7-4 Class: HP_MemoryModule Property name Property implementation CIM_ManagedElement Caption A string describing the DIMM index and the DIMM physical location. CIM_ManagedSystemElement OperationalStatus Enumerator indicating the memory module operational status. • OperationalStatus[0]: contains overall memory module status • OperationalStatus[1]: contains detailed memory module status (as needed) For details, see the Memory Module Status.
  • Page 68 Table 7-4 Class: HP_MemoryModule Property name Property implementation RemovalConditions 3 (Removable when off) CIM_Chip CIM_PhysicalMemory DataWidth Data width of memory module in bits InterleavePosition Position of memory module in an interleave Capacity Total capacity of memory module in bytes TotalWidth Total width of memory module in bits Speed Speed of memory module in nanoseconds...
  • Page 69: Hp_Memoryboard

    HP_MemoryBoard 7-3-4 The class HP_MemoryBoard represents a physical memory board on Integrity Servers. There is an instance of this class for each memory board in the system. Table 7-6 Class: HP_MemoryBoard Property name Property implementation CIM_ManagedElement A string describing the physical location of the memory Caption board.
  • Page 70 Table 7-6 Class: HP_MemoryBoard Property name Property implementation A string describing the physical location of the memory ElementName board. On Integrity systems, a memory board instance can be a cell board, a system board or a memory extender board. CIM_PhysicalPackage RemovalConditions Removal conditions of the memory board: •...
  • Page 71: Hp_Memoryredundancyset

    Table 7-7 Memory Board Status Condition OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Memory board has a configuration • • 3 (Degraded) 3 (Degraded) error, for example, there is a • • Memory board status: Degraded Memory board status: problem with the board release Configuration error latch (unlock error) or there is an improper configuration of memory...
  • Page 72 Table 7-8 Class: HP_MemoryRedundancySet Property name Property implementation RedundancyStatus The current memory redundancy status as follows: • 2 (Fully Redundant)—System is operating properly in the Advanced Memory Protection mode given in the TargetConfiguration property. • 3 (Degraded Redundancy)—Degraded Redundancy can occur in either of 2 conditions: ○...
  • Page 73: Hp_Memorycollection

    Table 7-8 Class: HP_MemoryRedundancySet Property name Property implementation ConfigurationsAvailable An array containing Advanced Memory Protection configurations supported on this system (the CurrentConfiguration and TargetConfiguration properties will contain one of these values). Each indexed position in the array contains one supported configuration.
  • Page 74: Hp_Hostedmemorycollection

    Table 7-9 Class: HP_MemoryCollection Property name Property implementation GroupStatusDescriptions GroupStatusDescriptions[0] contains descriptive text per GroupOperationalStatus[0]: • Memory collection status: OK • Memory collection status: Degraded • Memory collection status: Unknown HP_MemoryCollection Table 7-10 Memory Collection Status RedundancyStatus ‘worst’ ‘worst’ GroupOperationalStatus from OperationalStatus[0], OperationalStatus[0],...
  • Page 75: Hp_Memberofmemorycollection

    Table 7-11 Class: HP_HostedMemoryCollection Property name Property implementation Antecedent ref: HP_ComputerSystem Dependent ref: HP_MemoryCollection HP_MemberOfMemoryCollection 7-3-8 The class HP_ MemberOfMemoryCollection represents an association between HP_MemoryCollection and HP_MemoryModule or HP_MemoryBoard. Table 7-12 Class: HP_MemberOfMemoryCollection Property name Property implementation CIM_MemberOfCollection HP_MemberOfMemoryCollection Collection ref: HP_MemoryCollection Member ref: CIM_PhysicalElement...
  • Page 76: Hp_Realizesmemorymodule

    Table 7-14 Class: HP_HostedMemoryRedundancySet Property name Property implementation HP_HostedMemoryRedundancySet OwningElement ref: HP_ComputerSystem OwnedElement ref: HP_MemoryRedundancySet HP_RealizesMemoryModule 7-3-11 The class HP_RealizesMemoryModule represents an association between HP_MemoryModule and HP_Memory. Table 7-15 Class: HP_RealizesMemoryModule Property name Property implementation CIM_Dependency CIM_Realizes HP_RealizesMemoryModule Antecedent ref: HP_MemoryModule Dependent ref: HP_Memory HP_ MemoryModuleSlot...
  • Page 77: Hp_Memoryboardslot

    Table 7-16 Class: HP_MemoryModuleSlot Property name Property implementation HPQ:HP_MemoryModuleSlot:x-y, where: • x is the board/cartridge number where the memory slot is located. On cellular systems, x includes the cabinet and cell board number. • y is the memory socket number where the memory slot is located Description A string describing the DIMM slot index and the DIMM...
  • Page 78: Hp_Memorymoduleinslot

    Table 7-17 Class: HP_MemoryBoardSlot Property name Property implementation HPQ:HP_MemoryBoardSlot:x, where x is the board/cartridge number. Description A string describing the memory board physical location. ElementName A string describing the memory board physical location. CIM_PhysicalConnector ConnectorLayout 1 (Other) ConnectorDescription A string describing the memory board physical location.
  • Page 79: Hp_ Memorymoduleslotonboard

    Table 7-19 Class: HP_MemoryBoardInSlot Property name Property implementation HP_MemoryBoardInSlot ref: HP_MemoryBoardSlot — ref: HP_MemoryBoard — HP_ MemoryModuleSlotOnBoard 7-3-16 The class HP_MemoryModuleSlotOnBoard represents an association between an HP_MemoryModuleSlot and the HP_MemoryBoard that contains it. Table 7-20 Class: HP_MemoryModuleSlotOnBoard Property name Property implementation CIM_Component CIM_Container HP_MemoryModuleSlotOnBoard...
  • Page 80: Hp_Memoryboardslotlocation

    Table 7-21 Class: HP_ MemoryModuleSlotLocation Property name Property implementation Name HPQ:HP_MemoryModuleSlotLocation:x-y, where: • x is the board/cartridge number where the memory module slot is located. On cellular systems, x includes the cabinet and cell board number. • y is the memory socket index where the memory module slot is located PhysicalPosition x-y, where:...
  • Page 81: Hp_Memorymoduleslotelementlocation

    Table 7-22 Class: HP_ MemoryBoardSlotLocation Properties Property implementation Description A string describing the physical location of the memory board. ElementName A string describing the physical location of the memory board. CIM_Location Name HPQ:HP_MemoryBoardSlotLocation:x, where x is the board/cartridge number where the memory board slot is located PhysicalPosition x, where x is the board/cartridge number where the...
  • Page 82: Hp_Memoryboardslotelementlocation

    HP_MemoryBoardSlotElementLocation 7-3-20 The class HP_MemoryBoardSlotElementLocation extends the class HP_ElementLocation and is used to associate a memory board slot (HP_MemoryBoardSlot) with its corresponding location (HP_MemoryBoardSlotLocation). There is an instance of this class for each memory board slot in the system (whether the slot is occupied or not). Table 7-24 Class: HP_MemoryBoardSlotElementLocation Properties...
  • Page 83: Supported Indications

    Table 7-26 Class: HP_SystemMemoryBoardSlot Properties Property implementation HP_SystemMemoryBoardSlot GroupComponent ref: HP_ComputerSystemChassis PartComponent ref: HP_MemoryBoardSlot Supported indications There are no indications specific to the system memory profile implementation. 6BSystem memory 83...
  • Page 84: Pci Device

    PCI Device Overview This provider implements the profiles listed to support PCI devices installed in Integrity servers. The following table details the profiles implemented and files installed by this provider. Table 8-1 Overview Implemented Profiles • DMTF PCI Device Profile •...
  • Page 85: Hp_Pcibridge

    Table 8-2 Class: HP_PCIDevice Property name Property implementation CIM_LogicalDevice CreationClassName HP_PCIDevice DeviceID Unique identifier for this PCI device instance SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName HP_ComputerSystem.Name CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_PCIController CIM_PCIDevice BusNumber The bus number where this PCI device resides DeviceNumber The device number assigned to this PCI device for the FunctionNumber...
  • Page 86 Table 8-3 Class: HP_PCIBridge Property name Property implementation ElementName A hardware ID for this PCI device provided by the operating system CIM_ManagedSystemElement Name The product name for the PCI device. CIM_LogicalDevice CreationClassName HP_PCIBridge DeviceID Unique identifier for this PCI device instance SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName...
  • Page 87: Hp_Pcicard

    HP_PCICard 8-3-3 HP_PCICard is used to represent physical PCI adapter card installed on Integrity Servers. There is an instance of this class for each PCI adapter card present in the system. Table 8-4 Class: HP_PCICard Property name Property Implemenation CIM_ManagedElement Caption A string describing the physical location of the PCI device.
  • Page 88: Hp_Pcicardinslot

    Table 8-5 Class: HP_PCISlot Property name Property implementation CIM_ManagedSystemElement Name A string describing the full PCI slot location, which includes cabinet and cell number on cellular systems. CIM_PhysicalElement CreationClassName HP_PCISlot A string describing the full PCI slot location, which includes cabinet and cell number on cellular systems. Description A string describing the full PCI slot location, which includes cabinet and cell number on cellular systems.
  • Page 89: Hp_Realizespcidevice

    Table 8-6 Class: HP_PCICardInSlot Property name Property implementation Antecedent References HP_PCISlot Dependent References HP_PCICard HP_RealizesPCIDevice 8-3-6 HP_RealizesPCIDevice is used to represent an association between HP_PCIDevice and HP_PCICard that realizes this PCI device. Table 8-7 Class: HP_RealizesPCIDevice Property name Property implementation Antecedent References HP_PCICard Dependent...
  • Page 90: Hp_Elementlocation

    Table 8-10 Class: HP_Location Property name Property implementation CIM_ManagedElement Caption A string describing the full PCI slot location, which includes cabinet and cell number on cellular systems. Description A string describing the full PCI slot location, which includes cabinet and cell number on cellular systems. ElementName A string describing the full PCI slot location, which includes cabinet and cell number on cellular systems.
  • Page 91: Management Processor Lite

    Management Processor Lite Overview The profiles are implemented, and the following files are installed by this provider. Table 9-1 Overview Implemented Profiles • HP Management Processor (MP) Lite Profile 1.0 Provider Installation Files • HPWmiMgmtProc.dll • HPWmiMgmtProcLite.mof Use cases For use cases, see the HP Management Processor (MP) Lite Profile. Class implementations The following classes are implemented for Integrity server platforms where available.
  • Page 92 Table 9-2 Class: HP_ManagementProcessor Property name Property implementation Description Description of the Management Processor in the format: <X> HP Management Processor - <product name> where <X> indicates the MP Is Active or Inactive/Disabled and <product name> is the name of the MP product (same as the product name in property ElementName) For example, Active HP Management Processor –...
  • Page 93 Table 9-2 Class: HP_ManagementProcessor Property name Property implementation StatusDescriptions Descriptive text per OperationalStatus. • StatusDescriptions[0] text per OperationalStatus[0]: ○ Management Processor Status: Unknown ○ Management Processor Status: OK ○ Management Processor Status: Degraded ○ Management Processor Status: Error • StatusDescriptions[1] text per OperationalStatus[1]: ○...
  • Page 94: Cim_Softwareidentity

    Table 9-2 Class: HP_ManagementProcessor Property name Property implementation ControllerType Enumerator indicating the model or type of management processor (see the HPWmiMgmtProcLite.mof file). • 0 (Unknown) • 1 (Other) • 2 (PCI Board-Remote Insight Lights Out Edition II (RILOE II)) • 3 (Embedded Integrated Lights Out Controller (iLO)) •...
  • Page 95 VersionString String indicating the MP firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties. Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Management Processor Firmware IdentifyingInfoValue HPQ:xxx, where xxx represents the target...
  • Page 96: Hp_Mpcollection

    Table 9-3 Class: CIM_SoftwareIdentity Property name Property implementation IdentifyingInfoType CIM:SoftwareFamily ReleaseDate The MP firmware date (in DMTF datetime format) HP_MPFirmware HP_MPCollection 9-3-3 HP_MPCollection represents the collection of all management processor controller systems in a computer system. HP_MPCollection extends the class HP_GroupSystemSpecificCollection to forward group operational status.
  • Page 97: Hp_Mphostedcollection

    Table 9-4 Class: HP_MPCollection Property name Property implementation GroupStatusDescription GroupStatusDescriptions[0] text per GroupOperationalStatus[0]: • Aggregate Management Processor Collection Status: Unknown • Aggregate Management Processor Collection Status: OK • Aggregate Management Processor Collection Status: Degraded • Aggregate Management Processor Collection Status: Error HP_MPCollection HP_MPHostedCollection 9-3-4...
  • Page 98: Hp_Mpmemberofcollection

    Table 9-6 Class: HP_MPComponentCS Property name Property implementation PartComponent ref: HP_ManagementProcessor HP_MPMemberOfCollection 9-3-6 HP_MPMemberOfCollection extends the class CIM_MemberOfCollection and associates a management processor to the collection to which it belongs. The following properties are implemented. Table 9-7 Class: HP_MPMemberOfCollection Property name Property implementation CIM_MemberOfCollection CIM_MemberOfPolicyCollection...
  • Page 99: Cim_Installedsoftwareidentity

    CIM_InstalledSoftwareIdentity 9-3-8 CIM_InstalledSoftwareIdentity associates a management processor to its corresponding installed firmware. The Windows-specific implementation class is HP_MPInstalledFirmwareIdentity. The following properties are implemented. Table 9-9 Class: CIM_InstalledSoftwareIdentity Property name Property implementation CIM_InstalledSoftwareIdentity HP_MPInstalledFirmwareIdentity System ref: HP_ManagementProcessor InstalledSoftware ref: HP_MPFirmware Supported indications There are no indications specific to the management processor profile implementation.
  • Page 100: Sel Record Log

    SEL Record Log Overview 10-1 This provider supports the IPMI System Event Log (SEL) on Integrity systems. The following profiles are implemented, and the following files are installed by this provider. Table 10-1 Overview Implemented Profiles • HP Record Log Profile (P00109) Provider Installation Files •...
  • Page 101 Table 10-2 Class: HP_CommonRecordLog Properties Property name Property implementation OperationalStatus OperationalStatus[0] indicates the highest severity of IPMI SEL log entries and will contain one of the following: • 2 (OK), only informational or repaired events exist in the IPMI SEL log •...
  • Page 102: Hp_Commonlogentry

    Table 10-2 Class: HP_CommonRecordLog Properties Property name Property implementation Default value is 30 days. LogBackUpDays Percentage of log currently used. LogPercentFull Table 10-3 Implemented Methods for HP_CommonRecordLog Class Method Name Method Implementation ClearLog See HP Record Log profile (P00109) RepairAll See HP Record Log profile (P00109) HP_CommonLogEntry 10-3-2...
  • Page 103 Table 10-4 Class: HP_CommonLogEntry Property name Property implementation CIM_LogEntry InstanceID HPQ:n, where n is the IPMI SEL event number LogInstanceID HPQ:HPQ_CommonRecordLog LogName Complex-Wide IPMI System Event Log (SEL) events RecordID IPMI SEL event number CreationTimeStamp IPMI SEL log event creation time stamp HP_CommonLogEntry RecordDataType 3 (Delimited)
  • Page 104: Hp_Logmanagesrecord

    Table 10-4 Class: HP_CommonLogEntry Property name Property implementation ServerHardwareArchitecture • 0 (Unknown) • 8 (IA-64) LoggerType 2 (Server) Table 10-5 Implemented Methods for HP_CommonLogEntry Class Method Name Method Implementation Repair Refer to HP Record Log profile (P00109) HP_LogManagesRecord 10-3-3 HP_ LogManagesRecord extends the class CIM_ LogManagesRecord and associates instances of HP_CommonRecordLog and HP_CommonLogEntry.
  • Page 105: Supported Indications

    Supported indications 10-4 There are no indications specific to the profile registration profile implementation. 9BSEL Record Log 105...
  • Page 106: Blade System Lite

    Blade System Lite Overview 11-1 The following profiles are implemented, and the following files are installed by this provider. Table 11-1 Overview Implemented Profiles • HP Blade System Lite Profile 1.0 Provider Installation Files • HPWmiBlade.DLL • HPWmiBlade.mof Use cases 11-2 For use cases, see the HP Blade System Lite Profile.
  • Page 107 Table 11-2 Class: HP_BladeEnclosureCS Property name Property implementation CIM_ManagedSystemElement OperationalStatus • 0 (Unknown), enclosure status: Unknown • 2 (OK), enclosure status: OK • 3 (Degraded), enclosure status: Degraded • 6 (Error), enclosure status: Error StatusDescriptions StatusDescriptions[0] per OperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown •...
  • Page 108: Hp_Bladeenclosurecollection

    Table 11-2 Class: HP_BladeEnclosureCS Property name Property implementation HP_BladeEnclosureCS ManagementIPAddress The enclosure’s management IP address ManagementURL The URL of the enclosure’s management web-based user interface HP_BladeEnclosureCollection 11-3-2 HP_BladeEnclosureCollection extends the class HP_GroupSystemSpecificCollection to aggregate the enclosure’s group operational status. The following properties are implemented. Table 11-3 Class: HP_BladeEnclosureCollection Property name...
  • Page 109: Hp_Bladesystemcomponent

    Table 11-3 Class: HP_BladeEnclosureCollection Property name Property implementation GroupStatusDescriptions GroupStatusDescriptions[0] per GroupOperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown • Server Blade Enclosure and Onboard Administrator status: OK • Server Blade Enclosure and Onboard Administrator status: Degraded • Server Blade Enclosure and Onboard Administrator status: Error HP_BladeEnclosureCollection...
  • Page 110: Hp_Bladeenclosuregrouphostedcollection

    HP_BladeEnclosureGroupHostedCollection 11-3-5 HP_BladeEnclosureGroupHostedCollection extends the class HP_GroupHostedCollection and associates the enclosure’s computer system instance to the blade enclosure collection instance. The following properties are implemented. Table 11-6 Class: HP_BladeEnclosureGroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_BladeEnclosureGroupHostedCollection Antecedent ref: HP_ComputerSystem Dependent ref: HP_BladeEnclosureCollection CIM_SoftwareIdentity...
  • Page 111: Cim_Elementsoftwareidentity

    VersionString String indicating the blade enclosure firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties. Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Server Blade Enclosure Firmware IdentifyingInfoValue HPQ:OA IdentifyingInfoType...
  • Page 112: Supported Indications

    Table 11-9 Class: CIM_InstalledSoftwareIdentity Property name Property implementation CIM_InstalledSoftwareIdentity HP_BladeEnclosureInstalledFWIdentity System ref: HP_BladeEnclosureCS InstalledSoftware ref: HP_BladeEnclosureFW Supported indications 11-4 There are no indications specific to the blade system profile implementation. 10BBlade System Lite 112...
  • Page 113: Ethernet Teaming

    Ethernet Teaming Overview 12-1 The following profiles are implemented, and the following files are installed by this provider. Table 12-1 Overview Implemented Profiles HP Ethernet Teaming 1.0 Provider Installation Files • HPWinEthAdapterCollection.dll • HPWinEthBootcodeVersion.dll • HPWinEthBootcodeVersionToPort.dll • HPWinEthDevice.dll • HPWinEthernetPort.dll •...
  • Page 114: Class Implementations

    Table 12-1 Overview Provider Installation Files continued • HPWinEthernetPort.mof • HPWinEthernetPortStatistics.mof • HPWinEthernetProvider.mof • HPWinEthErrorMetadata.mof • HPWinEthEventSettings.mof • HPWinEthGroupHostedCollection.mof • HPWinEthIPHostedAccessPoint.mof • HPWinEthIPProtocolEndpoint.mof • HPWinEthLANEndpoint.mof • HPWinEthLANEndpointToStats.mof • HPWinEthLANHostedAccessPoint.mof • HPWinEthMemberOfCollection.mof • HPWinEthPortToLANEndpoint.mof • HPWinEthPortToStats.mof • HPWinEthProvRegs.mof • HPWinEthPXEVersion.mof • HPWinEthPXEVersionToPort.mof •...
  • Page 115 Table 12-2 Class: HP_EthernetPort Property name Property implementation CIM_ManagedSystemElement Name Physical Device Object (PDO) name (for example, \Device\NTPNP_PCI0017) HealthState 5 (OK) if port has link, 20 (Major Failure) otherwise OperationalStatus[0] 2 (OK) if port has link, 6 (Error) otherwise CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled).
  • Page 116: Hp_Ethernetdevice

    HP_EthernetDevice 12-3-2 HP_EthernetDevice associates an Ethernet Port to the containing Computer System. The Windows implementation class is HP_WinEthDevice. Table 12-3 Class: HP_EthernetDevice Property name Property implementation CIM_Component CIM_SystemComponent CIM_SystemDevice Key:GroupComponent ref:HP_ComputerSystem Key:PartComponent ref:HP_EthernetPort HP_EthernetTeam 12-3-3 HP_EthernetTeam models Ethernet Redundancy Sets (Ethernet Teams). The Windows implementation class is HP_WinEthRedundancySet.
  • Page 117: Hp_Ethernetteammember

    Table 12-4 Class: HP_EthernetTeam Property name Property implementation TypeOfSet • 2 (N+1) • 3 (Load Balanced). HP_GroupRedundancySet GroupOperationalStatus • 2 (OK) • 3 (Degraded) • 6 (Error) HP_EthernetTeam ActiveMaximumTransmissionUnit Current maximum transmission unit in bytes Speed The current bandwidth of the team in bits per second TeamCapabilities[] Capabilities of an Ethernet Team (for example, Fast Path Failover).
  • Page 118: Hp_Hostedethernetteam

    Table 12-5 Class: HP_EthernetTeamMember Property name Property implementation Role • 0 (Unknown) • 1 (None) • 2 (Tx/Rx – Transmit/Receive) • 3 (Tx – Transmit only) • 4 (Standby – Spare) HP_HostedEthernetTeam 12-3-5 HP_HostedEthernetTeam associates Ethernet Teams to the containing Computer System. The Windows implementation class is HP_WinHostedEthernetTeam.
  • Page 119: Hp_Ethernetporttolanendpoint

    Table 12-7 Class: HP_EthernetLANEndpoint Property name Property implementation OperationalStatus[0] • 2 (OK) • 3 (Degraded) • 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint Key:CreationClassName HP_WinEthLANEndpoint Key:SystemCreationClassName HP_ComputerSystem.CreationClassName Key:SystemName Name of Server CIM_ProtocolEndpoint NameFormat GUID ProtocolFType 6 (Ethernet CSMA/CD) CIM_LANEndpoint MACAddress...
  • Page 120: Hp_Ethernetteamtolanendpoint

    HP_EthernetTeamToLANEndpoint 12-3-8 HP_ EthernetTeamToLANEndpoint associates Ethernet Teams to Ethernet LAN Endpoints. The Windows implementation class is HP_WinEthRedundancySetToLANEndpoint. Table 12-9 Class: HP_EthernetTeamToLANEndpoint Property name Property implementation CIM_Dependency Key:Antecedent ref:HP_EthernetTeam Key:Dependent ref:HP_EthernetLANEndpoint HP_EthernetTeamToLANEndpoint HP_EthernetLANHostedAccessPoint 12-3-9 HP_EthernetLANHostedAccessPoint associates LAN Endpoints to the Computer System. The Windows implementation class is HP_WinEthLANHostedAccessPoint.
  • Page 121: Hp_Ethernetstatistics

    HP_EthernetStatistics 12-3-11 The following table lists the property implementation for HP_EthernetPortStatistics. The Windows implementation class is HP_WinEthernetPortStatistics. 11BEthernet Teaming 121...
  • Page 122: Hp_Ethernetportstatisticaldata

    Table 12-12 Class: HP_EthernetStatistics Property name Property implementation CIM_ManagedElement Caption • For Ethernet Teams, same as associated HP_WinEthRedundancySet.Caption • For Ethernet Ports, same as associated HP_WinEthernetPort.Caption Description Local Area Connection # ElementName Same as Caption CIM_StatisticalData Key:InstanceId System GUID of the associated Ethernet Port or LAN Endpoint SampleInterval StatisticTime...
  • Page 123: Hp_Ethernetlanendpointstatisticaldata

    Table 12-13 Class: HP_EthernetPortStatisticalData Property name Property implementation CIM_ElementStatisticalData Key:ManagedElement ref:HP_EthernetPort Key:Stats ref:HP_EthernetStatistics HP_EthernetPortStatisticalData HP_EthernetLANEndpointStatisticalData 12-3-13 HP_EthernetLANEndpointStatisticalData associates Ethernet LAN Endpoints to Ethernet LAN Endpoint Statistics. The Windows implementation class is HP_WinEthLANEndpointToStats. Table 12-14 Class: HP_EthernetLANEndpointStatisticalData Property name Property implementation CIM_ElementStatisticalData Key:ManagedElement ref:HP_EthernetLANEndpoint...
  • Page 124: Hp_Ethernetmemberofcollection

    HP_EthernetMemberOfCollection 12-3-15 HP_EthernetMemberOfCollection associates Ethernet Ports and Ethernet Teams to the Ethernet Collection. The Windows implementation class is HP_WinEthMemberOfCollection. Table 12-16 Class: HP_EthernetMemberOfCollection Property name Property implementation CIM_MemberOfCollection Key:Collection ref:HP_EthernetCollection Key:Member ref:HP_EthernetPort or ref:HP_EthernetTeam CIM_MemberOfPolicyCollection Included See the CIM_EthernetMemberOfPolicy mof HP_EthernetMemberOfCollection HP_EthernetGroupHostedCollection 12-3-16...
  • Page 125: Hp_Ethiphostedaccesspoint

    Table 12-18 Class: CIM_IPProtocolEndpoint Property name Property implementation CIM_ManagedSystemElement Key:Name System GUID for the associated Ethernet LAN Endpoint, concatenated with the IP Address. HealthState Same as associated LAN endpoint OperationalStatus[0] Same as associated LAN endpoint CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint...
  • Page 126: Cim_Softwareidentity

    CIM_SoftwareIdentity 12-3-19 The following table lists the property implementation for CIM_SoftwareIdentitiy, The Windows-specific implementation classes are HP_WinEthBootcodeVersion and HP_WinEthPXEVersion. Table 12-20 Class: CIM_SoftwareIdentity Property name Property implementation CIM_ManagedElement Caption Same as associated Ethernet Port Description Same as associated Ethernet Port ElementName PCI vendor ID CIM_ManagedSystemElement...
  • Page 127: Hp_Location

    Table 12-21 Class: CIM_ElementSoftwareIdentity Property name Property implementation CIM_ElementSoftwareIdentity ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) HP_Location 12-3-21 The following table lists the property implementation for HP_location. The Windows implementation classes is HP_WinEthLocation. Table 12-22 Class: HP_Location Property name Property implementation CIM_ManagedElement Caption...
  • Page 128: Hp_Etheventsettings

    Table 12-23 Class: HP_ElementLocation Property name Property implementation Key: PhysicalLocation ref:HP_Location HP_ElementLocation HP_WinElementLocation HP_EthEventSettings 12-3-23 HP_EthEventSettings models configurable Ethernet Indication settings. The Windows implementation class is HP_WinEthEventSettings. Table 12-24 Class: HP+EthEventSettings Property name Property implementation CIM_SettingData Caption HP Ethernet Event Provider configurable settings for Windows Description HP Ethernet Event Provider configurable settings for...
  • Page 129: Supported Indications

    Table 12-24 Class: HP+EthEventSettings Property name Property implementation MonitorLANEndpoints If enabled, events related to HP_WinEthLANEndpoint are generated. Default, disabled. MonitorPorts If enabled, events related to HP_WinEthernetPort are generated. Default, enabled. MonitorRedundancySets If enabled, events related to HP_WinEthRedundancySet are generated. Default, true. PolInterval The longest interval between network status polls, in seconds.
  • Page 130 Table 12-25 HP_AlertIndication: Redundancy Lost Property name Property implementation RecommendedActions[] View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information. SystemCreationClassName CreationClassName of the computer system generating the indication.
  • Page 131 Table 12-25 HP_AlertIndication: Redundancy Lost Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 132 Table 12-26 HP_AlertIndication: Redundancy Increased Property name Property implementation OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemGUID...
  • Page 133 Table 12-27 HP_AlertIndication: Redundancy Decreased Property name Property implementation PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description The Ethernet Team has transitioned from Fully Redundant or Degraded Redundancy to Degraded Redundancy due to a failed or degraded team member. AlertingManagedElement WBEM path of the Ethernet Team (HP_WinEthRedundancySet) reporting decreased...
  • Page 134 Table 12-27 HP_AlertIndication: Redundancy Decreased Property name Property implementation SystemProductId Product ID of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication VariableName[0] FailedMemberPath VariableTypes[0] 1 (string) VariableValues[0] WBEM path of the failed Ethernet Port, HP_WinEthernetPort ImpactedDomain •...
  • Page 135 Table 12-28 HP_AlertIndication: Full Redundancy Restored Property name Property implementation AlertType 2 (Communications Alert) Event Id Provider Name Ethernet RecommendedActions[] None SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary The Ethernet Team’s redundancy has increased to Fully Redundant...
  • Page 136 Table 12-28 HP_AlertIndication: Full Redundancy Restored Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 137 Table 12-29 HP_AlterIndication: Connectivity Lost Property name Property implementation HP_AlertIndication Summary The Network interface has lost connectivity. EventCategory 9 (Network Device) EventSubCategory • 11 (Ethernet Port) • 12 ( Ethernet Team) • 13 (Ethernet LAN Endpoint) NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType •...
  • Page 138 Table 12-29 HP_AlterIndication: Connectivity Lost Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment Table 12-30 HP_AlertIndication: Connectivity Restored Property name...
  • Page 139 Table 12-30 HP_AlertIndication: Connectivity Restored Property name Property implementation OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemGUID...
  • Page 140 Table 12-31 Optional HP_AlertIndication: Team member status change Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description An Ethernet Team member’s status has changed, further information is available in the variable information of this indication.
  • Page 141 Table 12-31 Optional HP_AlertIndication: Team member status change Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemProductId Product ID of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the...
  • Page 142 Table 12-31 Optional HP_AlertIndication: Team member status change Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 143 Table 12-32 Optional HP_AlertIndication: Team Member Role Change Property name Property implementation NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 144 Table 12-32 Optional HP_AlertIndication: Team Member Role Change Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment Table 12-33 Optional HP_AlertIndication: Team Member Dropped Property name...
  • Page 145 Table 12-33 Optional HP_AlertIndication: Team Member Dropped Property name Property implementation OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating...
  • Page 146 Table 12-34 Optional HP_AlertIndication: Team Member Added Property name Property implementation PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description An Ethernet Team member has been added to the team, further information is available in the variable information of this indication. This is an optional indication that can be disabled through the Ethernet Event Provider settings.
  • Page 147 Table 12-34 Optional HP_AlertIndication: Team Member Added Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication VariableNames[0] MemberPath VariableTypes[0] 1 (string) VariableValues[0] WBEM path of the Ethernet Port, HP_WinEthernetPort, added to the team. ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
  • Page 148 Table 12-35 Optional HP_AlertIndication: Network Interface No Longer Available Property name Property implementation Event Id Provider Name Ethernet RecommendedActions[] View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information. SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 149 Table 12-35 Optional HP_AlertIndication: Network Interface No Longer Available Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 150 Table 12-36 HP_AlertIndication: New Network Interface Available Property name Property implementation NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build>...
  • Page 151 Table 12-37 HP_AlertIndication: Team Active Member Count Change Property name Property implementation CIM_AlertIndication Description The number of active adapters in an Ethernet team has changed. This is due an Ethernet Team member transitioning from OK to Degraded or Error. Further information is available in the variable information of this indication.
  • Page 152 Table 12-37 HP_AlertIndication: Team Active Member Count Change Property name Property implementation SystemProductId Product ID of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication VariableNames[0] PreviousCount, VariableTypes[0] 5 (uint32) VariableValues[0] Previous Count of active adapters VariableNames[1] CurrentCount VariableTypes[1]...
  • Page 153 Table 12-38 Optional HP_AlertIndication: Fatal Error Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) Event Id Provider Name Ethernet RecommendedActions[] Contact HP Support. SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary The event provider has encountered a fatal error and...
  • Page 154 Table 12-38 Optional HP_AlertIndication: Fatal Error Property name Property implementation VariableNames[2] State 2, VariableTypes[2] 5 (uint32) VariableValues[2] Changed state. ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
  • Page 155 Table 12-39 Optional HP_AlertIndication: Warning Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary The event provider was unable to access an information source. The event provider will still function, but the capability to detect network changes may be impaired.
  • Page 156 Table 12-39 Optional HP_AlertIndication: Warning Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment 11BEthernet Teaming 156...
  • Page 157: Hpsa_Arraysystem

    Smart Array Overview 13-1 The HP Smart Array data sheet describes both host-based Smart Array HBA devices and externally attached MSA devices. This implementation excludes fibre-attached devices (for example MSA1000 and MSA1500). The following profiles are implemented, and the following files are installed by this provider. Table 13-1 Overview Implemented Profiles...
  • Page 158 Table 13-2 Class: HPSA_ArraySystem (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller/Storage System name and location Examples: • Smart Array in Slot 3, for internal • MSA500 in SystemCab03, for external CIM_ManagedSystemElement OperationalStatus[0] Overall status of the Array System and attached devices.
  • Page 159: Hpsa_Arraycontroller

    HPSA_ArrayController 13-3-2 HPSA_ArrayController represents the controller. There is one per HBA and can have multiple controllers for external subsystems. Table 13-3 Class: HPSA_ArrayController (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller name and location Examples: • Smart Array in Slot 3, for internal •...
  • Page 160: Hpsa_Storagevolume

    Table 13-3 Class: HPSA_ArrayController (CIM_ComputerSystem) Property name Property implementation CacheSizeTotal See HP Smart Array Profile CacheState See HP Smart Array Profile CacheStatus See HP Smart Array Profile CacheWritePercent See HP Smart Array Profile ControllerStatus See HP Smart Array Profile ExpandPriority See HP Smart Array Profile NumberOfPorts See HP Smart Array Profile...
  • Page 161: Hpsa_Diskdrive

    Table 13-4 Class: HPSA_StorageVolume (CIM_StorageVolume) Property name Property implementation DeltaReservation ExtentStatus[0] This indicates extended status for the volume. • 2 (None) • 11 (Rebuild – Volume is currently rebuilding data) IsBasedOnUnderlyingRedundancy False NoSinglePointOfFailure • True – RAID 1 or above •...
  • Page 162: Hpsa_Storageextent

    Table 13-5 Class: HPSA_DiskDrive (CIM_DiskDrive) Property name Property implementation OperationalStatus[0] Operational Status for the disk drive • 0 (Unknown) • 2 (OK) • 5 (Predictive Failure) • 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSA_DiskDrive...
  • Page 163: Hpsa_Diskdrivefirmware

    Table 13-6 Class: HPSA_StorageExtent (CIM_StorageExtent) Property name Property implementation CIM_ManagedElement ElementName Disk location (for example, Port: 1E Box 1 Bay: 5) CIM_ManagedSystemElement Name Serial number of drive OperationalStatus[0] Operational Status for the disk drive • 0 (Unknown) • 2 (OK) •...
  • Page 164: Hpsa_Physicalpackage

    Table 13-7 Class: HPSA_DiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedElement ElementName TargetType value CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement Caption Disk Drive Firmware Description Disk Drive Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Disk drive vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue...
  • Page 165: Hpsa_Arraycontrollerphysicalpackage

    Table 13-8 Class: HPSA_PhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Manufacturer Controller vendor string Model Controller model string PartNumber N/A–Not Available for this implementation SerialNumber Controller Serial number for HBAs Chassis serial number for External subsystems HBA / Subsystem Serial number Version N/A–Not Available for this implementation CIM_PhysicalPackage...
  • Page 166: Hpsa_Diskphysicalpackage

    Table 13-9 Class: HPSA_ArrayControllerPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation HPSA_ ArrayControllerPhysicalPackage HPSA_DiskPhysicalPackage 13-3-9 HPSA_DiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive. Table 13-10 Class: HPSA_DiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Disk location (for example, Port: 1E Box 1 Bay: 5) CIM_ManagedSystemElement Name...
  • Page 167: Hpsa_Storageenclosureprocessor

    Table 13-11 Class: HPSA_StorageEnclosure (HP_StorageEnclosure) Property name Property implementation ElementName Port: <m> Box: <n>, where <m> is the port and <n> is the box number CIM_ManagedSystemElement Name Port: <m> Box: <n>, where <m> is the port and <n> is the box number CIM_PhysicalElement CreationClassName HPSA_StorageEnclosure...
  • Page 168: Hpsa_Portcontroller

    Table 13-12 Class: HPSA_StorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation CIM_ManagedSystemElement OperationalStatus[0,1, 2, 3 ] Operational status for enclosure and associated power supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows.
  • Page 169: Hpsa_Daport

    Table 13-13 Class: HPSA_PortController (CIM_PortController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location (for example, Smart Array in Slot 3) CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSA_PortController DeviceID Controller serial number SystemCreationClassName HPSA_ArraySystem...
  • Page 170: Hpsa_Spiport

    Table 13-14 Class: HPSA_DAPort (CIM_DAPort) Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSA_DAPort DeviceID Opaque key SystemCreationClassName HPSA_ArraySystem SystemName HPSA_ArraySystem.Name CIM_LogicalPort UsageRestriction 2 (Front-End Only) CIM_DAPort HPSA_DAPort HPSA_SPIPort 13-3-14 HPSA_SPIPort represents the front-end port for an external Storage Subsystem.
  • Page 171: Hpsa_Firmware

    Table 13-15 Class: HPSA_SPIPort (CIM_SPIPort) Property name Property implementation CreationClassName HPSA_SPIPort DeviceID Opaque key SystemCreationClassName HPSA_ArraySystem SystemName HPSA_ArraySystem.Name CIM_LogicalPort CIM_SPIPort HPSA_SPIPort HPSA_Firmware 13-3-15 HPSA_Firmware represents the firmware installed on a Smart Array controller. Table 13-16 Class: HPSAM_Firmware (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedElement ElementName...
  • Page 172: Hpsa_Primordialpool

    Table 13-17 Class: HPSA_EnclosureFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedElement ElementName TargetType value CIM_ManagedSystemElement Name Storage Enclosure Processor Firmware CIM_LogicalElement Caption Storage Enclosure Processor Firmware Description Storage Enclosure Processor Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Processor Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure vendor string...
  • Page 173: Hpsa_Storagepool

    Table 13-18 Class: HPSA_PrimordialPool (CIM_StoragePool) Property name Property implementation RemainingManagedSpace Remaining raw space on controller. This is calculated by summing the remaining space on all drives attached to the controller. TotalManagedSpace Total raw space available to controller. This is calculated by summing the total space on all drives connected to this controller.
  • Page 174: Hpsa_Storagesetting

    Table 13-20 Class: HPSA_MediaAccessStatData (CIM_MediaAccessStatData) Property name Property implementation CIM_StatisticalData InstanceID Opaque key SampleInterval CIM_MediaAccessStatData HPSA_MediaAccessStatData AbortedCommands See HP Smart Array Profile BadTargetErrors See HP Smart Array Profile DRQTimeouts See HP Smart Array Profile ECCRecoveredReadErrors See HP Smart Array Profile ElementName Disk location (For example, Port: 1E Box 1 Bay: 5) FailedReadRecovers...
  • Page 175: Hpsa_Drivecage

    Table 13-21 Class: HPSA_StorageSetting (CIM_StorageSetting) Property name Property implementation CIM_ManagedElement ElementName RAID <n>, where <n> is the raid description Examples: • RAID 0 • RAID 1+0 • RAID 5 • RAID 6 CIM_SettingData InstanceID Opaque key CIM_StorageSetting ChangeableType 0 (Not Changeable) DataRedundancyGoal •...
  • Page 176: Hpsa_Scsiprotocolendpoint

    Table 13-22 Class: HPSA_DriveCage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Port <n>, where <n> is the name of the port this drive cage is connected For example, Port J3 CIM_ManagedSystemElement Name Serial Number of drive cage N/A—When serial number is not available CIM_PhysicalElement CreationClassName HPSA_DriveCage...
  • Page 177: Hpsa_Scsiprotocolcontroller

    Table 13-23 Class: HPSA_SCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint CreationClassName HPSA_SCSIProtocolEndpoint Name HBA Serial Number SystemCreationClassName HPSA_ArraySystem SystemName HPSA_ArraySystem.Name CIM_ProtocolEndpoint ProtocolIFType 0 (Unknown) CIM_SCSIProtocolEndpoint ConnectionType 1 (Other) OtherConnectionType Role 4 (Both Initiator and Target) HPSA_SCSIProtocolEndpoint HPSA_SCSIProtocolController 13-3-23...
  • Page 178: Hpsa_Redundancyset

    Table 13-24 Class: HPSA_SCSIProtocolController (CIM_SCSIProtocolController) Property name Property implementation CreationClassName HPSA_SCSIProtocolController DeviceID Opaque key SystemCreationClassName HPSA_ArraySystem SystemName HPSA_ArraySystem.Name CIM_ProtocolController MaxUnitsControlled CIM_ SCSIProtocolController HPSA_ SCSIProtocolController HPSA_RedundancySet 13-3-24 HPSA_RedundancySet represents controller redundancy if there is more than one controller in a redundant configuration (for example MSA500 with two controllers.) Table 13-25 Class: HPSA_RedundancySet (CIM_RedundancySet) Property name...
  • Page 179: Hpsa_Storagespecificcollection

    Table 13-26 Class: HPSA_StorageRedundancySet (CIM_StorageRedundancySet) Property name Property implementation CIM_ManagedElement ElementName Storage Redundancy Set CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key CIM_RedundancySet LoadBalanceAlgorithm 2 (No Load Balancing) MaxNumberSupported MinNumberNeeded RedundancyStatus • 2 (Fully Redundant) • 3 (Degraded redundancy) TypeOfSet[0] 5 (Limited Sparing) CIM_StorageRedundancySet HPSA_StorageRedundancySet HPSA_StorageSpecificCollection...
  • Page 180: Hpsa_Drivecagelocation

    HPSA_DriveCageLocation 13-3-27 HPSA_DriveCageLocation represents a location string for the drive cage. Table 13-28 Class: HPSA_DriveCageLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Drive Cage Description Drive Cage ElementName Drive Cage CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Duplex Top, Duplex Bottom, Non Duplex ElementLocationTagDesc 22 (Drive Cage) LocationInformation[0]...
  • Page 181: Hpsa_Diskdrivelocation

    Table 13-29 Class: HPSAArraySystemLocation (HP_Location) Property name Property implementation ElementName Controller name and location Examples: • Smart Array in Slot 3, for internal • MSA500 in SystemCab03, for external CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag • PCI Slot Number—when ‘Adapter’ is specified in ElementLocationTagDesc •...
  • Page 182: Hpsa_Arraycontrollerlocation

    Table 13-30 Class: HPSA_DiskDriveLocation (HP_Location) Property name Property implementation CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag • Bay Number of Disk Drive— When ‘Bay’ is specified in ElementLocationTagDesc. • SCSI ID of Disk Drive—When ‘SCSI ID’ is specified in ElementLocationTagDesc ElementLocationTagDesc •...
  • Page 183: Hpsa_Storagecapabilities

    Table 13-31 Class: HPSA_ArrayControllerLocation (HP_Location) Property name Property implementation ElementLocationTag for Internal HBAs: PCI Slot Number Examples: • 3 – for adapter in PCI Slot 3 • 0 – for Embedded adapter For external controllers: Controller number per chassis label Examples: •...
  • Page 184: Hpsa_Product

    Table 13-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities) Property name Property implementation DataRedundancyDefault • 1—When number of drives is an odd number) • 2—When number of drives is an even number (For example, pool can be configured for mirroring.) DataRedundancyMax • 1—When number of drives is an odd number •...
  • Page 185: Hpsa_Storageenclosure Location

    Table 13-33 Class: HPSA_Product (CIM_Product) Property name Property implementation IdentifyingNumber Opaque key Name String representing the Marketing name Vendor Version Firmware version of HBA or Storage System HPSA_Product HPSA_StorageEnclosure Location 13-3-33 HPSA_StorageEnclosureLocation represents a location string for the enclosure. Table 13-34 Class: HPSA_StorageEnclosureLocation (HP_Location) Property name Property implementation...
  • Page 186: Hpsa_Storagevolumestoragesetting (Association)

    HPSA_StorageVolumeStorageSetting (Association) 13-3-35 Table 13-36 Class: HPSA_StorageVolumeStorageSetting (CIM_ElementSettingDate) Property name Property implementation ManagedElement HPSA_StorageVolume SettingData HPSA_StorageSetting IsCurrent 1 (Set to Is Current) IsDefault 1 (Set to Is Default) HPSA_PrimordialPoolStorageCapabilities (Association) 13-3-36 Table 13-37 Class: HPSA_PrimordialPoolStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities HPSA_StorageCapabilities ManagedElement...
  • Page 187: Hpsa_Arraysystemportcontroller (Association)

    Table 13-40 Class: HPSA_ArraySystemSCSIProtocolController (CIM_SystemDevice) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_SCSIProtocolController HPSA_ArraySystemPortController (Association) 13-3-40 Table 13-41 Class: HPSA_ArraySystemPortController (CIM_Logicaldentity) Property name Property implementation SameElement HPSA_ArraySystem SystemElement HPSA_PortController HPSA_ArraySystemDiskDrive (Association) 13-3-41 Table 13-42 Class: HPSA_ArraySystemDiskDrive (CIM_SystemDevice) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent...
  • Page 188: Hpsa_Arraysystemspiport (Association)

    HPSA_ArraySystemSPIPort (Association) 13-3-44 Table 13-45 Class: HPSA_ArraySystemSPIPort (CIM_SystemDevice) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_SPIPort. HPSA_ArraySystemDAPort (Association) 13-3-45 Table 13-46 Class: HPSA_ArraySystemDAPort (CIM_SystemDevice) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_DAPort. HPSA_ArraySystemPrimordialPool (Association) 13-3-46 Table 13-47 Class: HPSA_ArraySystemPrimordialPool (CIM_HostedStoragePool) Property name Property implementation GroupComponent...
  • Page 189: Hpsa_Arraysystemarraycontroller (Association)

    HPSA_ArraySystemArrayController (Association) 13-3-49 Table 13-50 Class: HPSA_ArraySystemArrayController (CIM_ComponentCS) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_ArrayController HPSA_StorageEnclosureStorageEnclosureProcessor 13-3-50 (Association) Table 13-51 Class: HPSA_StorageEnclosureStorageEnclosureProcessor (CIM_SystemPackaging) Property name Property implementation Antecedent HPSA_StorageEnclosure Dependent HPSA_StorageEnclosureProcessor HPSA_ProductPhysicalPackage (Association) 13-3-51 Table 13-52 Class: HPSA_ProductPhysicalPackage (CIM_ProductPhysicalPackage) Property name Property implementation GroupComponent...
  • Page 190: Hpsa_Physicalpackagestorageenclosure (Association)

    Table 13-54 Class: HPSA_PhysicalPackageArrayControllerPhysicalPackage (CIM_Container) Property name Property implementation GroupComponent HPSA_PhysicalPackage PartComponent HPSA_ArrayControllerPhysicalPackage HPSA_PhysicalPackageDiskPhysicalPackage 13-3-54 (Association) Table 13-55 Class: HPSA_PhysicalPackageDiskPhysicalPackage (CIM_Container) Property name Property implementation GroupComponent HPSA_PhysicalPackage PartComponent HPSA_DiskPhysicalPackage HPSA_PhysicalPackageStorageEnclosure (Association) 13-3-55 Table 13-56 Class: HPSA_PhysicalPackageStorageEnclosure (CIM_Container) Property name Property implementation GroupComponent HPSA_PhysicalPackage PartComponent...
  • Page 191: Hpsa_Primordialpoolstorageextent (Association)

    HPSA_PrimordialPoolStorageExtent (Association) 13-3-58 Table 13-59 Class: HPSA_PrimordialPoolStorageExtent (CIM_ConcreteComponent) Property name Property implementation GroupComponent HPSA_PrimordialPool PartComponent HPSA_StorageExtent HPSA_StorageSpecificCollectionArraySystem 13-3-59 (Association) Table 13-60 Class: HPSA_StorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection HPSA_StorageSpecificCollection Member HPSA_ArraySystem HPSA_ArrayControllerRedundancySet (Association) 13-3-60 Table 13-61 Class: HPSA_ArrayControllerRedundancySet (CIM_MemberOfCollection) Property name Property implementation Collection...
  • Page 192: Hpsa_Firmwarearraysystem (Association)

    Table 13-63 Class: HPSA_ArraySystemFirmware (CIM_InstalledSoftwareIdentity) Property name Property implementation InstalledSoftware HPSA_Firmware System HPSA_ArraySystem HPSA_SCSIProtocolControllerStorageVolume 13-3-63 (Association) Table 13-64 Class: HPSA_SCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation Antecedent HPSA_SCSIProtocolController Dependent HPSA_StorageVolume DeviceAccess 2 (Read Write) DeviceNumber Device LUN number HPSA_FirmwareArraySystem (Association) 13-3-64 Table 13-65 Class: HPSA_FirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name...
  • Page 193: Hpsa_Diskdrivediskdrivefirmware (Association)

    HPSA_DiskDriveDiskDriveFirmware (Association) 13-3-66 Table 13-67 Class: HPSA_DiskDriveDiskDriveFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSA_DiskDriveFirmware Dependent HPSA_DiskDrive ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) HPSA_DiskDriveStorageExtent (Association) 13-3-67 Table 13-68 Class: HPSA_DiskDriveStorageExtent (CIM_MediaPresent) Property name Property implementation Antecedent HPSA_DiskDrive Dependent HPSA_StorageExtent HPSA_DiskPhysicalPackageDiskDrive (Association) 13-3-68...
  • Page 194: Hpsa_Spareextentstorageextent (Association)

    Table 13-71 Class: HPSA_PrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Property implementation Antecedent HPSA_PrimordialPool Dependent HPSA_StoragePool SpaceConsumed Bytes consumed by storage pool HPSA_SpareExtentStorageExtent (Association) 13-3-71 Table 13-72 Class: HPSA_SpareExtentStorageExtent (CIM_Spared) Property name Property implementation Antecedent HPSA_StorageExtent Dependent HPSA_StorageExtent HPSA_SpareExtentStorageRedundancySet (Association) 13-3-72 Table 13-73 Class: HPSA_SpareExtentStorageRedundancySet (CIM_IsSpare) Property name Property implementation...
  • Page 195: Hpsa_Spiportscsiprotocolendpoint (Association)

    HPSA_SPIPortSCSIProtocolEndpoint (Association) 13-3-75 Table 13-76 Class: HPSA_SPIPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent HPSA_SPIPort Dependent HPSA_SCSIProtocolEndpoint HPSA_StorageGroupHostedCollection (Association) 13-3-76 Table 13-77 Class: HPSA_StorageGroupHostedCollection (HP_GroupHostedCollection) Property name Property implementation Antecedent HP_ComputerSystem Dependent HPSA_StorageSpecificCollection HPSA_PhysicalPackageArraySystem (Association) 13-3-77 Table 13-78 Class: HPSA_PhysicalPackageArraySystem (CIM_ComputerSystemPackage) Property name Property implementation Antecedent...
  • Page 196: Hpsa_Drivecagedrivecagelocation (Association)

    Table 13-80 Class: HPSA_DiskDriveMediaAccessStatData (CIM_ElementStatisticalData) Property name Property implementation Stats HPSA_MediaAccessStatData HPSA_ArrayControllerPhysicalPackageArrayControllerLo 13-3-80 cation (Association) Table 13-81 Class: HPSA_ArrayControllerPhysicalPackageArrayControllerLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSA_ArrayControllerPhysicalPackage PhysicalLocation HPSA_ArrayControllerLocation HPSA_PhysicalPackageArraySystemLocation 13-3-81 (Association) Table 13-82 Class: HPSA_PhysicalPackageArraySystemLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSA_PhysicalPackage PhysicalLocation...
  • Page 197: Hpsa_Storageenclosureenclosurelocation (Association)

    Table 13-84 Class: HPSA_DiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSA_DiskPhysicalPackage PhysicalLocation HPSA_DiskDriveLocation HPSA_SCSIProtocolEndpointSCSIProtocolController 13-3-84 (Association) Table 13-85 Class: HPSA_SCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement) Property name Property implementation AvailableSAP HPSA_SCSIProtocolEndpoint ManagedElement HPSA_SCSIProtocolController HPSA_StorageEnclosureEnclosureLocation (Association) 13-3-85 Table 13-86 Class: HPSA_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSA_StorageEnclosure PhysicalLocation...
  • Page 198 Table 13-87 HPSA_DeviceIndication: Physical Drive status changed to OK Property name Property implementation EventID 1401 ProviderName SmartArray RecommendedActions No action required. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical Drive status is now OK EventCategory...
  • Page 199 Table 13-87 HPSA_DeviceIndication: Physical Drive status changed to OK Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 200 Table 13-88 HPSA_DeviceIndication: Physical Drive status changed to ERROR Property name Property implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical Drive status is now ERROR. EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure)
  • Page 201 Table 13-88 HPSA_DeviceIndication: Physical Drive status changed to ERROR Property name Property implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion...
  • Page 202 Table 13-89 HPSA_DeviceIndication: Physical Drive status changed to REBUILDING Property name Property implementation HP_AlertIndication Summary Physical Drive is now Rebuilding EventCategory 6 (Primary Storage) ProbableCause 35 (Performance Degraded) NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType •...
  • Page 203 Table 13-89 HPSA_DeviceIndication: Physical Drive status changed to REBUILDING Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk firmware version string...
  • Page 204 Table 13-90 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE Property name Property implementation Summary Physical Drive status is now PREDICTIVE FAILURE EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType •...
  • Page 205 Table 13-90 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk firmware version string HWLogicalLocation Physical Disk Location string For example, Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
  • Page 206 Table 13-91 HPSA_StorageVolumeIndication: Logical Drive status changed to OK Property name Property implementation NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 207 Table 13-91 HPSA_StorageVolumeIndication: Logical Drive status changed to OK Property name Property implementation HPSA_StorageVolumeIndication DeviceOperationalStatus Current OperationalStatus values for Storage Volume • DeviceOperationalStatus[0]: HPSA_StorageVolume.OperationalStatus[0] • DeviceOperationalStatus[1]: HPSA_StorageVolume.OperationalStatus[1] (This index is only populated if there is addional Vendor unique status available) DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume •...
  • Page 208 Table 13-92 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR Property name Property implementation NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 209 Table 13-92 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR Property name Property implementation HP_DeviceIndication HPSA_StorageVolumeIndication DeviceOperationalStatus Current OperationStatus values for Storage Volume • DeviceOperationalStatus[0]: HPSA_StorageVolume.OperationalStatus[0] • DeviceOperationalStatus[1]: HPSA_StorageVolume.OperationalStatus[1] (This index is only populated if there is addional Vendor unique status available) DeviceOperationalStatusPrevious Previous OperationStatus values for Storage Volume •...
  • Page 210 Table 13-93 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded Property name Property implementation EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 •...
  • Page 211 Table 13-93 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded Property name Property implementation HWLogicalLocation Logical drive number & RAID Level. For example, LogicalDrive 1 (RAID 1+0). HP_DeviceIndication HPSA_StorageVolumeIndication DeviceOperationalStatus Current OperationStatus values for Storage Volume • DeviceOperationalStatus[0]: HPSA_StorageVolume.OperationalStatus[0] • DeviceOperationalStatus[1]: HPSA_StorageVolume.OperationalStatus[1] (This index is only populated if there is addional Vendor unique status available)
  • Page 212 Table 13-94 HPSA_DeviceIndication: Controller status changed to OK Property name Property implementation EventCategory 6 (Primary Storage) ProbableCause NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system...
  • Page 213 Table 13-94 HPSA_DeviceIndication: Controller status changed to OK Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string...
  • Page 214 Table 13-95 HPSA_DeviceIndication: Controller status changed to ERROR Property name Property implementation ProbableCause 24 (I/O device error) NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system...
  • Page 215 Table 13-95 HPSA_DeviceIndication: Controller status changed to ERROR Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string...
  • Page 216 Table 13-96 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE Property name Property implementation ProbableCause NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 217 Table 13-96 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string...
  • Page 218 Table 13-97 HPSA_DeviceIndication: Controller Redundancy has been lost Property name Property implementation ProbableCause NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 219 Table 13-97 HPSA_DeviceIndication: Controller Redundancy has been lost Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string...
  • Page 220 Table 13-98 HPSA_DeviceIndication: Controller Redundancy has been restored Property name Property implementation ProbableCause NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 221 Table 13-98 HPSA_DeviceIndication: Controller Redundancy has been restored Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string...
  • Page 222 Table 13-99 HPSA_DeviceIndication: Controller Battery status changed to OK Property name Property implementation ProbableCause NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 223 Table 13-99 HPSA_DeviceIndication: Controller Battery status changed to OK Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string...
  • Page 224 Table 13-100 HPSA_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation ProbableCause 99 (low battery) NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 •...
  • Page 225 Table 13-100 HPSA_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string...
  • Page 226 Table 13-101 HPSA_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 227 Table 13-101 HPSA_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer string...
  • Page 228 Table 13-102 HPSA_DeviceIndication: Controller Cache status changed to OK Property name Property implementation OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build>...
  • Page 229 Table 13-102 HPSA_DeviceIndication: Controller Cache status changed to OK Property name Property implementation HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number HP_DeviceIndication DeviceModel Array Controller Model string...
  • Page 230 Table 13-103 HPSA_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating...
  • Page 231 Table 13-103 HPSA_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number HP_DeviceIndication DeviceModel Array Controller Model string...
  • Page 232 Table 13-104 HPSA_DeviceIndication: Controller Cache status—Permanently Disabled Property name Property implementation OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating...
  • Page 233 Table 13-104 HPSA_DeviceIndication: Controller Cache status—Permanently Disabled Property name Property implementation HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number HP_DeviceIndication DeviceModel Array Controller Model string...
  • Page 234 Table 13-105 HPSA_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build>...
  • Page 235 Table 13-106 HPSA_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description Power Supply Status changed to a status of Redundant AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor AlertingElementFormat...
  • Page 236 Table 13-106 HPSA_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
  • Page 237 Table 13-107 HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1504 ProviderName SmartArray RecommendedActions Check enclosure for a failed power supply. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 238 Table 13-107 HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 239 Table 13-108 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation EventCategory 24 (Primary Storage Cooling) ProbableCause NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 •...
  • Page 240 Table 13-108 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string Table 13-109 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation CIM_Indication...
  • Page 241 Table 13-109 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication...
  • Page 242 Table 13-110 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description Temperature sensor Status changed to a status of Critical. Enclosure temperature is reaching maximum allowed temperature for normal operation, shutdown is imminent.
  • Page 243 Table 13-110 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short description of failure ImpactedDomain •...
  • Page 244 Table 13-111 HPSA_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1521 ProviderName SmartArray RecommendedActions No action required SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 245 Table 13-111 HPSA_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 246 Table 13-112 HPSA_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation HP_AlertIndication Summary Fan Status changed to Degraded. EventCategory 24 (Primary Storage Cooling) ProbableCause 94 (Fan failure) NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType •...
  • Page 247 Table 13-112 HPSA_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation HP_HardwareIndication HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string Table 13-113 HPSA_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication...
  • Page 248 Table 13-113 HPSA_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication...
  • Page 249: Overview

    FC HBA Overview 14-1 This provider implements the HP FC HBA Profile which describes the behavior of Fibre Channel host adapters supporting the SCSI (FCP) command set. A Fibre Channel adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports.
  • Page 250 Figure 14-1 Instance diagram for a single HBA with two controllers with one port on each controller 13BFC HBA 250...
  • Page 251: Get Statistics For Each Fibre Channel Port

    Get statistics for each Fibre Channel port 14-2-1 For each instance of HPFCHBA_ComputerSystem, find the corresponding instance of the associations HPFCHBA_ComputerSystemFCPort. For each association of HPFCHBA_ComputerSystemFCPort, get the corresponding instance of HPFCHBA_FCPort. For each instance of HPFCHBA_FCPort, get the corresponding instance of the association HPFCHBA_FCPortFCPortStatistics For each association instance of HPFCHBA_FCPortFCPortStatistics get the corresponding instance of HPFCHBA_FcPortStatistics.
  • Page 252 For each instance of association HPFCHBA_SoftwareIdentityDrvPortController, get the corresponding instance of HPFCHBA_SoftwareIdentityDrv. The VersionString property contains the driver version. Other properties of interest are Description, ElementName, and Manufacturer. For each instance of HPFCHBA_PortController, get the corresponding association HPFCHBA_PortControllerFirmwareIdentityFW. For each instance of association HPFCHBA_PortControllerFirmwareIdentityFW, get the corresponding instance of HPFCHBA_FirmwareIdentityFW.
  • Page 253: Hpfchba_Computersystem

    Figure 14-3 Discover HBA topology and attributes Class implementations 14-3 HPFCHBA_ComputerSystem 14-3-1 HPFCHBA_ComputerSystem is used to identify classes that represent the all Fibre Channel ports. Table 14-2 Class: HPFCHBA_ComputerSystem Property name Property implementation CIM_ManagedElement 13BFC HBA 253...
  • Page 254: Hpfchba_Fcport

    Table 14-2 Class: HPFCHBA_ComputerSystem Property name Property implementation Caption Fibre Channel System ElementName Fibre Channel System CIM_ManagedSystemElement Name GUID OperationalStatus • 0 (Unknown) • 1 (Other) • 2 (OK) • 3 (Degraded) • 6 (Error) StatusDescriptions • Unknown • Other •...
  • Page 255 Table 14-3 Class: HPFCHBA_FCPort Property name Property implementation OperationalStatus[0] • 0 (Unknown) • 2 (OK-Online) • 6 (Error) • 10 (Stopped) • 11 (In Service) StatusDescriptions[0] • Unknown • OK-Online • Offline • Bypassed • Diagnostics • Link down • Error •...
  • Page 256: Hpfchba_Portcontroller

    Table 14-3 Class: HPFCHBA_FCPort Property name Property implementation OtherPortType • other • Not present • Fabric • Public Loop • FL Port • Fabric Port • Fabric expansion port • Generic Fabric Port • Private Loop • Point to Point PortType 1 (Other) Speed...
  • Page 257: Hpfchba_Fcportstatistics

    Table 14-4 Class: HPFCHBA_PortController Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPFCHBA_PortController DeviceID NodeWWN:SerialNumber SystemCreationClassName HPFCHBA_ComputerSystem SystemName HPQ:GUID: 85408DBD-6A39-41CD-9E5A- 357AEA130BBF:NODEWWN:nodewwn, where nodewwn is the node’s WWN. CIM_Controller CIM_PortController ControllerType 4 (FC) HPFCHBA_FCPortStatistics 14-3-4...
  • Page 258: Hpfchba_Logicalportgroup

    Table 14-5 Class: HPFCHBA_FCPortStatistics Property name Property implementation CIM_FCPortStatistics CRCErrors HBAAPI_PORTSTATISTICS.InvalidCRCCount DumpedFrames HBAAPI_PORTSTATISTICS.DumpedFrames ErrorFrames HBAAPI_PORTSTATISTICS.ErrorFrames InvalidTransmissionWords HBAAPI_PORTSTATISTICS.InvalidTxWordCount LinkFailures HBAAPI_PORTSTATISTICS.LinkFailureCount LIPCount HBAAPI_PORTSTATISTICS.LIPCount LossOfSignalCounter HBAAPI_PORTSTATISTICS.LossOfSignalCount LossOfSyncCounter HBAAPI_PORTSTATISTICS.LossOfSyncCount NOSCount HBAAPI_PORTSTATISTICS.NOSCount PrimitiveSeqProtocolErrCount HBAAPI_PORTSTATISTICS.PrimitiveSeqProtocolErrCoun HPFCHBA_LogicalPortGroup 14-3-5 A collection of one or more ports logically grouped for administrative and discovery and topology purposes.
  • Page 259: Hpfchba_Physicalpackage

    HPFCHBA_PhysicalPackage 14-3-6 HPFCHBA_PhysicalPackage class represents the physical elements of the associated Fibre Channel port controller. Table 14-7 Class: HPFCHBA_PhysicalPackage Property name Property implementation CIM_ManagedElement ElementName Product Name CIM_ManagedSystemElement Name NodeWWN OperationalStatus[] 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) CIM_PhysicalElement CreationClassName HPFCHBA_PhysicalPackage Manufacturer...
  • Page 260: Hpfchba_Softwareidentitydrv

    Table 14-8 Class: HPFCHBA_Product Property name Property implementation IdentifyingNumber HBAAPI_ADAPTERATTRIBUTES.VendorSpecificID Name HPQ:GUID: 85408DBD-6A39-41CD-9E5A- 357AEA130BBF:NODEWWN:nodewwn where nodewwn is the node’s WWN. Vendor Manufacturer Version Board Version or N/A when not available HPFCHBA_SoftwareIdentityDrv 14-3-8 Table 14-9 Class: HPFCHBA_SoftwareIdentityDrv Property name Property implementation CIM_ManagedElement Caption FC HBA Driver...
  • Page 261: Hpfchba_Firmwareidentitybios

    Table 14-10 Class: HPFCHBA_FirmwareIdentityFW Property name Property implementation CIM_ManagedElement Caption FC HBA Firmware Description Description FC HBA Firmware details for Product Name, where product name is the product name of the HBA. ElementName FC HBA Firmware CIM_ManagedSystemElement Name NodeWWN CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FC HBA Firmware...
  • Page 262: Hpfchba_Scsiprotocolcontroller

    Table 14-11 Class: HPFCHBA_FirmwareIdentityBIOS (CIM_SoftwareIdentity) Property name Property implementation ClassificationDescriptions FC HBA Option ROM Classifications 11 (bios/fc) InstanceID HPQ:GUID: 85408DBD-6A39-41CD-9E5A- 357AEA130BBF:NODEWWN:nodewwn:HPFCHBA_Fi rmwareIdentityBIOS, where nodewwn is the node’s Manufacturer Manufacturer VersionString BIOS Version as reported by HBA TargetType HP BIOS UNKNOWN SerialNumber Serial Number MajorVersion...
  • Page 263: Hpfchba_Scsiprotocolendpoint

    Table 14-12 Class: HPFCHBA_SCSIProtocolController Property name Property implementation SystemName HPQ:GUID: 85408DBD-6A39-41CD-9E5A- 357AEA130BBF:NODEWWN:nodewwn, where nodewwn is the node’s WWN. SystemCreationClassName HPFCHBA_ComputerSystem CIM_ProtocolController MaxUnitsControlled CIM_SCSIProtocolController HPFCHBA_SCSIProtocolEndpoint 14-3-12 HPFCHBA_SCSIProtocolEndpoint represents SCSI protocol running through a port. Table 14-13 Class: HPFCHBA_SCSIProtocolEndpoint Property name Property implementation CIM_ManagedElement ElementName SCSI Protocol Endpoint...
  • Page 264: Hpfchba_Computersystemfcport

    HPFCHBA_GroupSystemSpecificCollection is used to represent the group status of all Fibre Channel ports. Table 14-14 Class: HPFCHBA_GroupSystemSpecificCollection Property name Property implementation CIM_ManagedElement Caption FC HBA Consolidated Status Description A consolidated OperationalStatus for all FCHBA_ComputerSystem instances ElementName FC HBA Consolidated Status CIM_Collection CIM_SystemSpecificCollection InstanceID...
  • Page 265: Hpfchba_Computersystemportcontroller

    HPFCHBA_ComputerSystemPortController 14-3-15 HPFCHBA_ComputerSystemPortController is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_PortController. Table 14-16 Class: HPFCHBA_ComputerSystemPortController Property name Property implementation CIM_Component CIM_SystemDevice HPFCHBA_ComputerSystemPortController GroupComponent ref:HPFCHBA_ComputerSystem PartComponent ref:HPFCHBA_PortController HPFCHBA_ComputerSystemSCSIProtocolController 14-3-16 HPFCHBA_ComputerSystemSCSIProtocolController is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_SCSIProtocolController. Table 14-17 Class: HPFCHBA_ComputerSystemSCSIProtocolController Property name...
  • Page 266: Hpfchba_Computersystemsoftwareidentitydrv

    Table 14-18 Class: HPFCHBA_ComputerSystemLogicalPortGroup Property name Property implementation Dependent ref:HPFCHBA_LogicalPortGroup HPFCHBA_ComputerSystemSoftwareIdentityDrv 14-3-18 HPFCHBA_ComputerSystemSoftwareIdentityDrv is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_SoftwareIdentityDrv. Table 14-19 Class: HPFCHBA_ComputerSystemSoftwareIdentityDrv Property name Property implementation CIM_Component CIM_SystemDevice HPFCHBA_ComputerSystemSoftwareIdentityDrv InstalledSoftware ref:HPFCHBA_SoftwareIdentityDrv System ref:HPFCHBA_ComputerSystem HPFCHBA_SystemServiceAccessPoint 14-3-19 HPFCHBA_SystemServiceAccessPoint is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_SCSIProtocolEndpoint.
  • Page 267: Hpfchba_Fcportlogicalportgroup

    Table 14-21 Class: HPFCHBA_FCPortFCPortStatistics Property name Property implementation CIM_ElementStatisticalData HPFCHBA_FCPortFCPortStatistics ManagedElement ref:HPFCHBA_FCPort Stats ref:HPFCHBA_FcPortStatistics HPFCHBA_FCPortLogicalPortGroup 14-3-21 HPFCHBA_FCPortLogicalPortGroup is used to represent an association between HPFCHBA_FCPort and HPFCHBA_LogicalPortGroup. Table 14-22 Class: HPFCHBA_FCPortLogicalPortGroup Property name Property implementation CIM_MemberOfCollection HPFCHBA_FCPortLogicalPortGroup Collection ref:HPFCHBA_LogicalPortGroup Member ref:HPFCHBA_FCPort HPFCHBA_FCPortSCSIProtocolEndpoint 14-3-22...
  • Page 268: Hpfchba_Portcontrollerfcport

    Table 14-24 Class: HPFCHBA_SCSIProtocolControllerFCPort Property name Property implementation CIM_Dependency CIM_ProtocolControllerForDevice CIM_ProtocolControllerForPort HPFCHBA_SCSIProtocolControllerFCPort Antecedent ref:HPFCHBA_SCSIProtocolController Dependent ref:HPFCHBA_FCPort HPFCHBA_PortControllerFCPort 14-3-24 HPFCHBA_PortControllerFCPort is used to represent an association between HPFCHBA_PortController and HPFCHBA_FCPort. Table 14-25 Class: HPFCHBA_PortControllerFCPort Property name Property implementation CIM_Dependency CIM_ControlledBy HPFCHBA_PortControllerFCPort Antecedent ref:HPFCHBA_PortController Dependent...
  • Page 269: Hpfchba_Portcontrollerfirmwareidentityfw

    HPFCHBA_SoftwareIdentityDrvPortController is used to represent an association between HPFCHBA_PortController and HPFCHBA_SoftwareIdentityDrv. Table 14-27 Class: HPFCHBA_SoftwareIdentityDrvPortController Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity HPFCHBA_SoftwareIdentityDrvPortController Antecedent ref:HPFCHBA_SoftwareIdentityDrv Dependent ref:HPFCHBA_PortController HPFCHBA_PortControllerFirmwareIdentityFW 14-3-27 HPFCHBA_PortControllerFirmwareIdentityFW is used to represent an association between HPFCHBA_PortController and HPFCHBA_FirmwareIdentityFW. Table 14-28 Class: HPFCHBA_PortControllerFirmwareIdentityFW Property name Property implementation...
  • Page 270: Hpfchba_Productphysicalcomponent

    HPFCHBA_ProductPhysicalComponent 14-3-29 HPFCHBA_ProductPhysicalComponent is used to represent an association between HPFCHBA_Product and HPFCHBA_PhysicalPackage. Table 14-30 Class: HPFCHBA_ProductPhysicalComponent Property name Property implementation CIM_Component CIM_ProductPhysicalComponent HPFCHBA_ProductPhysicalComponent GroupComponent ref:HPFCHBA_Product PartComponent ref:HPFCHBA_PhysicalPackage HPFCHBA_SystemPackaging 14-3-30 HPFCHBA_SystemPackaging is used to represent an association between HPFCHBA_PhysicalPackage and HPFCHBA_ComputerSystem. Table 14-31 Class: HPFCHBA_SystemPackaging Property name...
  • Page 271: Hpfchba_Grouphostedcollection

    HPFCHBA_GroupHostedCollection 14-3-32 HPFCHBA_GroupHostedCollection is used to represent an association between CIM_ComputerSystem and HPFCHBA_GroupSystemSpecificCollection. Table 14-33 Class: HPFCHBA_GroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HPFCHBA_GroupHostedCollection Antecedent ref:CIM_ComputerSystem Dependent ref:HPFCHBA_GroupSystemSpecificCollection HPFCHBA_FCPortGroupSystemSpecific 14-3-33 HPFCHBA_FCPortGroupSystemSpecific is used to represent an association between HPFCHBA_FCPort and HPFCHBA_GroupSystemSpecificCollection.
  • Page 272: Hpfchba_Physicalelementlocation

    Table 14-35 Class: HPFCHBA_Location Property name Property implementation HP_Location ElementLocationTag slot number ElementLocationTagDesc 1 (slot) PhysicalPosition Location – PCI Slot x where x is the PCI slot number HPFCHBA_PhysicalElementLocation 14-3-35 HPFCHBA_PhysicalElementLocation is used to represent an association between the HPFCHBA_PhysicalPackage and HPFCHBA_Location. Table 14-36 Class: HPFCHBA_PhysicalElementLocation Property name...
  • Page 273: Hpsas_Arraysystem

    SAS HBA Overview 15-1 The HP SAS HBA Profile describes host based SAS HBA providers. The following table details the profiles implemented and files installed by this provider. Table 15-1 Overview Implemented Profiles • HP SAS HBA Provider Installation Files •...
  • Page 274: Hpsas_Arraycontroller

    Table 15-2 Class: HPSAS_ArraySystem (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus[0] Overall status of the Array System and attached devices. This is calculated as per the algorithm described in the HP SAS HBA Profile.
  • Page 275: Hpsas_Storagevolume

    Table 15-3 Class: HPSAS_ArrayController (CIM_ComputerSystem) Property name Property implementation OperationalStatus[0] Status for Array Controller • 0 (Unknown) • 2 (OK) • 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName HPSAS_ArrayController Name Controller Serial Number NameFormat Other...
  • Page 276 Table 15-4 Class: HPSAS_StorageVolume (CIM_ StorageVolume) Property name Property implementation RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSAS_StorageVolume DeviceID Opaque Key SystemCreationClassName HPSAS_ArraySystem SystemName HPSAS_ArraySystem.Name CIM_StorageExtent ConsumableBlocks Total Number of blocks on the volume. BlockSize Block Size in bytes DataRedundancy • 1 (for RAID 0) •...
  • Page 277: Hpsas_Diskdrive

    HPSAS_DiskDrive 15-3-4 HPSAS_DiskDrive represents the hard drives connected to SAS HBA controllers. Table 15-5 Class: HPSAS_DiskDrive (CIM_DiskDrive) Property name Property implementation CIM_ManagedElement ElementName Disk location For example, Bay: 5 CIM_ManagedSystemElement Name SAS Address OperationalStatus[0] Operational Status for the disk drive •...
  • Page 278: Hpsas_Storageextent

    HPSAS_StorageExtent 15-3-5 HPSAS_StorageExtent represents the consumable storage that is available on a disk drive. There is one instance per disk drive. Table 15-6 Class: HPSAS_StorageExtent (CIM_StorageExtent) Property name Property implementation CIM_ManagedElement ElementName Disk location For example, Bay: 5 CIM_ManagedSystemElement Name Serial number of drive OperationalStatus[0] Operational Status for the disk drive...
  • Page 279: Hpsas_Diskdrivefirmware

    HPSAS_DiskDriveFirmware 15-3-6 HPSAS_DiskDriveFirmware represents the firmware installed on a disk drive. There is one instance per disk drive. Table 15-7 Class: HPSAS_DiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedElement ElementName TargetType value CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement Caption Disk Drive Firmware Description Disk Drive Firmware CIM_SoftwareIdentity...
  • Page 280: Hpsas_Diskphysicalpackage

    Table 15-8 Class: HPSAS_PhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Name Controller Serial Number CIM_PhysicalElement CreationClassName HPSAS_PhysicalPackage Manufacturer Controller vendor string Model Controller model string PartNumber N/A–Not Available for this implementation SerialNumber Controller Serial Number HBA Serial number CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HPSAS_PhysicalPackage HPSAS_DiskPhysicalPackage 15-3-8...
  • Page 281: Hpsas_Portcontroller

    Table 15-9 Class: HPSAS_DiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_PhysicalPackage HotSwappable • TRUE—Drive is hot swappable • FALSE—Drive is not hot swappable RemovalConditions 2 (Not Applicable) HPSAS_DiskPhysicalPackage HPSAS_PortController 15-3-9 HPSAS_PortController represent the HBA in the host system. There is one instance per HBA. Table 15-10 Class: HPSAS_PortController (CIM_PortController) Property name...
  • Page 282: Hpsas_Firmware

    HPSAS_DAPort represents the front-end port for an HBA in the host system. Direct Attached implies that the array controller is attached to a local bus on the host (for example, PCI). Table 15-11 Class: HPSAS_DAPort (CIM_DAPort) Property name Property implementation CIM_ManagedElement ElementName Controller name and location, for example, HP 8 INT...
  • Page 283: Hpsas_Primordialpool

    Table 15-12 Class: HPSAS_Firmware (CIM_SoftwareIdentity) Property name Property implementation Name HBA Firmware CIM_LogicalElement Caption HBA Firmware Description HBA Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] HBA Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Controller Vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ:<TargetType value> Set to HPQ:HBA FW UNKNOWN VersionString Controller firmware version string HPSAS_Firmware...
  • Page 284: Hpsas_Primordialpoolnoraid

    Table 15-13 Class: HPSAS_PrimordialPool (CIM_StoragePool) Property name Property implementation HPSAS_PrimordialPool HPSAS_PrimordialPoolNoRaid 15-3-13 HPSAS_PrimordialPoolNoRaid represents the total raw storage managed by the array controller that is not assigned to raid volumes. Table 15-14 Class: HPSAS_PrimordialPoolNoRaid (CIM_StoragePool) Property name Property implementation CIM_ManagedElement ElementName Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3:...
  • Page 285: Hpsas_Storagesetting

    Table 15-15 Class: HPSAS_StoragePool (CIM_StoragePool) Property name Property implementation CIM_LogicalElement CIM_StoragePool InstanceID Opaque key PoolID Controller serial number:1 Primordial FALSE RemainingManagedSpace TotalManagedSpace Total raw space managed by this pool HPSAS_StoragePool HPSAS_StorageSetting 15-3-15 HPSAS_StorageSetting represents the current raid configuration for a Storage Volume. There is one instance per Storage Volume.
  • Page 286: Hpsas_Scsiprotocolendpoint

    Table 15-16 Class: HPSAS_StorageSetting (CIM_StorageSetting) Property name Property implementation PackageRedundancyGoal • 0 (RAID 0) • 1 (RAID 1) PackageRedundancyMax • 0 (RAID 0) • 1 (RAID 1) PackageRedundancyMin • 0 (RAID 0) • 1 (RAID 1) HPSAS_StorageSetting HPSAS_SCSIProtocolEndpoint 15-3-16 HPSAS_SCSIProtocolEndpoint represents an access point to storage resources. Table 15-17 Class: HPSAS_SCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name...
  • Page 287: Hpsas_Scsiprotocolcontroller

    HPSAS_SCSIProtocolController 15-3-17 HPSAS_SCSIProtocolController represents a view a SCSI resources on the controller. Table 15-18 Class: HPSAS_SCSIProtocolController (CIM_SCSIProtocolController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus[0] Operational status of the controller •...
  • Page 288: Hpsas_Storagespecificcollection

    Table 15-19 Class: HPSAS_StorageRedundancySet (CIM_StorageRedundancySet) Property name Property implementation CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key CIM_RedundancySet LoadBalanceAlgorithm 2 (No Load Balancing) MaxNumberSupported MinNumberNeeded RedundancyStatus • 2 (Fully Redundant) • 4 (Redundancy Lost) TypeOfSet[0] 5 (Limited Sparing) CIM_StorageRedundancySet HPSAS_StorageRedundancySet HPSAS_StorageSpecificCollection 15-3-19 HPSAS_StorageSpecificCollection represents a collection of SAS HBA controllers that are grouped together to report consolidated status.
  • Page 289: Hpsas_Arraysystemlocation

    HPSAS_ArraySystemLocation 15-3-20 HPSAS_ArraySystemLocation represents a location string for the HBA. Table 15-21 Class: HPSAS_ArraySystemLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Description Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 ElementName Controller name and location...
  • Page 290: Hpsas_Storagecapabilities

    Table 15-22 Class: HPSAS_DiskDriveLocation (HP_Location) Property name Property implementation PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number of Disk ElementLocationTagDesc 20 (Bay) HPSAS_DiskDriveLocation HPSAS_StorageCapabilities 15-3-22 HPSAS_StorageCapabilities represents the possible capabilities of a Storage Pool. Table 15-23 Class: HPSAS_StorageCapabilities (CIM_StorageCapabilities) Property name Property implementation CIM_ManagedElement ElementName...
  • Page 291: Hpsas_Product

    Table 15-23 Class: HPSAS_StorageCapabilities (CIM_StorageCapabilities) Property name Property implementation NoSinglePointOfFailure • True—When number of drives > 1 (For example, Pool can be configured for redundancy.) • False—When number of drives = 1 or Pool is NonRAID NoSinglePointOfFailureDefault • True—When number of drives > 1 (For example, Pool can be configured for redundancy.) •...
  • Page 292: Hpsas_Enclosurefirmware

    Table 15-25 Class: HPSAS_DriveCage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Port <m> Box <n>, where <m> is the name of the port this drive cage is connected and <n> is the Box Number For example, Port IE Box 1 CIM_ManagedSystemElement Name Serial Number of drive cage...
  • Page 293: Hpsas_Storageenclosure

    Table 15-26 Class: HPSAS_EnclosureFirmware (CIM_SoftwareIdentity) Property name Property Implemenation CIM_LogicalElement Caption Storage Enclosure Firmware Description Storage Enclosure Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure Vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ:<TargetType value> VersionString Enclosure firmware string HPSAS_EnclosureFirmware HPSAS_StorageEnclosure 15-3-26...
  • Page 294: Hpsas_Storageenclosureprocessor

    Table 15-27 Class: HPSAS_StorageEnclosure (HP_StorageEnclosure) Property name Property implementation SerialNumber Enclosure Serial Number N/A is reported if there is no serial number (for example, internal enclosures). Opaque key Version N/A—Not Available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) CIM_PhysicalFrame CIM_Chassis HP_StorageEnclosure Location...
  • Page 295: Hpsas_Storageenclosurelocation

    Table 15-28 Class: HPSAS_StorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName HPSAS_StorageEnclosureProcessor Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated[0] 2 (Other) IdentifyingDescriptions[0] Other Vendor Specific Name OtherDedicatedDescriptions[0] SDE - indicates Storage Device Enclosure OtherIdentifyingInfo[0] Vendor:SerialNumber enclosure is attached to For example, HP:2SUJ1029...
  • Page 296: Hpsas_Drivecagediskdrive (Association)

    HPSAS_DriveCageDiskDrive (Association) 15-3-29 Table 15-30 Class: HPSAS_DriveCageDiskDrive (CIM_Container) Property name Property implementation GroupComponent HPSAS_DriveCage PartComponent HPSAS_DiskPhysicalPackage HPSAS_StorageEnclosureDriveCage (Association) 15-3-30 Table 15-31 Class: HPSAS_StorageEnclosureDriveCage (CIM_Container) Property name Property implementation GroupComponent HPSAS_StorageEnclosure PartComponent HPSAS_DriveCage HPSAS_StorageEnclosureEnclosureLocation 15-3-31 (Association) Table 15-32 Class: HPSAS_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property name Property implementation Element...
  • Page 297: Hpsas_Storagevolumestoragesetting (Association)

    Table 15-34 Class: HPSAS_StorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSAS_EnclosureFirmware Dependent HPSAS_StorageEnclosureProcessor ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) HPSAS_StorageEnclosureStorageEnclosureProcessor 15-3-34 (Association) Table 15-35 Class: HPSAS_StorageEnclosureStorageEnclosureProcessor (CIM_systemPackaging) Property name Property implementation Antecedent HPSAS_StorageEnclosure Dependent HPSAS_StorageEnclosureProcessor HPSAS_StorageVolumeStorageSetting (Association) 15-3-35 Table 15-36 Class: HPSAS_StorageVolumeStorageSetting (CIM_ElementSettingData)
  • Page 298: Hpsas_Storagepoolstoragecapabilities (Association)

    HPSAS_PrimordialPoolNoRaidStorageCapabilities 15-3-37 (Association) Table 15-38 Class: HPSAS_PrimordialPoolNoRaidStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities HPSAS_StorageCapabilities ManagedElement HPSAS_PrimordialPoolNoRaid HPSAS_StoragePoolStorageCapabilities (Association) 15-3-38 Table 15-39 Class: HPSAS_StoragePoolStorageCapabilities (CIM_ElementCapabilities ) Property name Property implementation Capabilities HPSAS_StorageCapabilities ManagedElement HPSAS_StoragePool HPSAS_ArraySystemSCSIProtocolController (Association) 15-3-39 Table 15-40 Class: HPSAS_ArraySystemSCSIProtocolController (CIM_SystemDevice) Property name Property implementation GroupComponent...
  • Page 299: Hpsas_Arraysystemstoragevolume (Association)

    Table 15-42 Class: HPSAS_ArraySystemDiskDrive (CIM_SystemDevice) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_DiskDrive HPSAS_ArraySystemStorageVolume (Association) 15-3-42 Table 15-43 Class: HPSAS_ArraySystemStorageVolume (CIM_SystemDevice) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_StorageVolume HPSAS_ArraySystemStorageExtent (Association) 15-3-43 Table 15-44 Class: HPSAS_ArraySystemStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent...
  • Page 300: Hpsas_Arraysystemprimordialpoolnoraid (Association)

    HPSAS_ArraySystemPrimordialPoolNoRaid (Association) 15-3-46 Table 15-47 Class: HPSAS_ArraySystemPrimordialPoolNoRaid (CIM_HostedStoragePool) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_PrimordialPoolNoRaid HPSAS_ArraySystemStoragePool (Association) 15-3-47 Table 15-48 Class: HPSAS_ArraySystemStoragePool (CIM_HostedStoragePool) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_StoragePool HPSAS_ComputerSystemArraySystem (Association) 15-3-48 Table 15-49 Class: HPSAS_ComputerSystemArraySystem (CIM_ComponentCS) Property name Property implementation GroupComponent...
  • Page 301: Hpsas_Storagepoolstorageextent (Association)

    Table 15-51 Class: HPSAS_ProductPhysicalPackage (CIM_ProductPhysicalPackage) Property name Property implementation GroupComponent HPSAS_Product PartComponent HPSAS_PhysicalPackage HPSAS_StoragePoolStorageExtent (Association) 15-3-51 Table 15-52 Class: HPSAS_StoragePoolStorageExtent (CIM_ConcreteComponent) Property name Property implementation GroupComponent HPSAS_StoragePool PartComponent HPSAS_StorageExtent HPSAS_PrimordialPoolStorageExtent (Association) 15-3-52 Table 15-53 Class: HPSAS_PrimordialPoolStorageExtent (CIM_ConcreteComponent) Property name Property implementation GroupComponent HPSAS_PrimordialPool PartComponent...
  • Page 302: Hpsas_Arraysystemfirmware (Association)

    Table 15-55 Class: HPSAS_StorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection HPSAS_StorageSpecificCollection Member HPSAS_ArraySystem HPSAS_StorageRedundancySetStorageExtent 15-3-55 (Association) Table 15-56 Class: HPSAS_StorageRedundancySetStorageExtent (CIM_MemberOfCollection) Property name Property implementation Collection HPSAS_StorageRedundancySet Member HPSAS_StorageExtent HPSAS_ArraySystemFirmware (Association) 15-3-56 Table 15-57 Class: HPSAS_ArraySystemFirmware (CIM_InstalledSoftwareIdentity) Property name Property implementation InstalledSoftware HPSAS_Firmware System...
  • Page 303: Hpsas_Diskdrivediskdrivefirmware (Association)

    Table 15-59 Class: HPSAS_FirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSAS_Firmware Dependent HPSAS_ArraySystem ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) HPSAS_DiskDriveDiskDriveFirmware (Association) 15-3-59 Table 15-60 Class: HPSAS_DiskDriveDiskDriveFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSAS_DiskDriveFirmware Dependent HPSAS_DiskDrive ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) •...
  • Page 304: Hpsas_Storageextentstoragevolume (Association)

    Table 15-63 Class: HPSAS_PrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Property implementation Antecedent HPSAS_PrimordialPool Dependent HPSAS_StoragePool SpaceConsumed Bytes consumed by storage pool HPSAS_StorageExtentStorageVolume (Association) 15-3-63 Table 15-64 Class: HPSAS_StorageExtentStorageVolume (CIM_BasedOn) Property name Property implementation Antecedent HPSAS_StorageExtent Dependent HPSAS_StorageVolume HPSAS_DAPortSCSIProtocolEndpoint (Association) 15-3-64 Table 15-65 Class: HPSAS_DAPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation...
  • Page 305: Supported Indications

    Table 15-67 Class: HPSAS_PhysicalPackageArraySystem (CIM_ComputerSystemPackage) Property name Property implementation Dependent HPSAS_ArraySystem HPSAS_PhysicalPackageArraySystemLocation 15-3-67 (Association) Table 15-68 Class: HPSAS_PhysicalPackageArraySystemLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSAS_PhysicalPackage Physical Location HPSAS_ArraySystemLocation HPSAS_DiskPhysicalPackageDiskDriveLocation 15-3-68 (Association) Table 15-69 Class: HPSAS_DiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSAS_DiskPhysicalPackage PhysicalLocation...
  • Page 306 Table 15-71 HPSAS_DeviceIndication: SAS HBA status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A SAS/SATA HBA status has changed from non-OK to AlertingMangedElement WBEM Path of controller AlertingElementFormat 2 (CIMObjectPath)
  • Page 307 Table 15-71 HPSAS_DeviceIndication: SAS HBA status OK Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
  • Page 308 Table 15-72 HPSAS_DeviceIndication: SAS HBA in Error state Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Replace the HBA. SystemName Name of the computer system generating the indication SystemCreationClassName...
  • Page 309 Table 15-72 HPSAS_DeviceIndication: SAS HBA in Error state Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 310 Table 15-73 HPSAS_DeviceIndication: Physical Drive status OK Property name Property implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical Drive Status is now OK EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription...
  • Page 311 Table 15-73 HPSAS_DeviceIndication: Physical Drive status OK Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 312 Table 15-74 HPSAS_DeviceIndication: Physical Drive status ERROR Property name Property implementation HP_AlertIndication SummaryProviderName HP SAS RecommendedActions Redundant power supply status OK. Check for failed or removed physical drives. EventCategorySystemName Name of the computer system generating the indication For example, 17 (Primary Storage Power) ProbableCauseSystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 313 Table 15-74 HPSAS_DeviceIndication: Physical Drive status ERROR Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name...
  • Page 314 Table 15-75 HPSAS_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 315 Table 15-75 HPSAS_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name...
  • Page 316 Table 15-76 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Replace drive immediately to avoid loss of data. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 317 Table 15-76 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 318 Table 15-77 HPSAS_DeviceIndication: Logical Drive status OK Property name Property implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Logical Drive status OK EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Logical Drive Status Changed to OK...
  • Page 319 Table 15-77 HPSAS_DeviceIndication: Logical Drive status OK Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment Table 15-78 HPSAS_DeviceIndication: Logical Drive status ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 5 (Major) IndicationTime...
  • Page 320 Table 15-78 HPSAS_DeviceIndication: Logical Drive status ERROR Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
  • Page 321 Table 15-79 HPSAS_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check status of physical drives. Degraded status may be caused by failed or missing physical drives, or a data recovery operation on one or more physical drives.
  • Page 322 Table 15-79 HPSAS_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 323 Table 15-80 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation ProviderVersion 2.2.0.0 NetworkAddresses List of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion The operating system version of the computer system generating the indication in the following format:...
  • Page 324 Table 15-80 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string Table 15-81 HPSAS_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity...
  • Page 325 Table 15-81 HPSAS_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation OSVersion The operating system version of the computer system generating the indication in the following format: <major>.<minor>.<build> SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the...
  • Page 326 Table 15-82 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Supply status has changed to Degraded Redundancy.
  • Page 327 Table 15-82 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription...
  • Page 328 Table 15-83 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor Status changed from non-OK to OK. AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime...
  • Page 329 Table 15-83 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
  • Page 330 Table 15-84 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS...
  • Page 331 Table 15-84 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
  • Page 332 Table 15-85 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
  • Page 333 Table 15-85 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
  • Page 334 Table 15-86 HPSAS_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 335 Table 15-86 HPSAS_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 336 Table 15-87 HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 337 Table 15-87 HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 338 Table 15-88 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 339 Table 15-88 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 340: Hpscsi_Hbacomputersystem

    SCSI HBA Overview 16-1 The HP SCSI HBA data sheet describes implementation of SCSI HBAs in a host system. The following profiles are implemented, and the following files are installed by this provider. Table 16-1 Overview Implemented Profiles HP SCSI HBA Profile Provider Installation Files •...
  • Page 341: Hpscsi_Storagevolume

    Table 16-2 Class: HPSCSI_HBAComputerSystem (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller name and location (for example, SCSI Controller Port 1 in Slot 4) CIM_ManagedSystemElement OperationalStatus Overall status of the system • 0 (Other) • 2 (OK) • 3 (Degraded) •...
  • Page 342: Hpscsi_Diskdrive

    Table 16-3 Class: HPSCSI_StorageVolume (CIM_ StorageVolume) Property name Property implementation Name SerialNumber + Vendor + Model (for example, 1020305+COMPAQ+ BD03685A24) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSCSI_StorageVolume DeviceID Opaque key SystemCreationClassName HPSCSI_HBAComputerSystem SystemName HBA index...
  • Page 343 Table 16-4 Class: HPSCSI_DiskDrive (CIM_DiskDrive) Property name Property implementation CIM_ManagedElement ElementName Disk name (or example, SCSIBUS:1 SCSIID:0) CIM_ManagedSystemElement Name Disk Serial Number OperationalStatus[0] • 0 (Other) • 2 (OK) • 5 (Predictive Failure) • 6 (ERROR) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState...
  • Page 344: Hpscsi_Storageextent

    HPSCSI_StorageExtent 16-3-4 HPSCSI_StorageExtent represents the consumable storage that is available on a disk drive. There is one instance per disk drive. Table 16-5 Class: HPSCSI_StorageExtent (CIM_StorageExtent) Property name Property implementation CIM_ManagedElement ElementName Disk name (for example, SCSIBUS:1 SCSIID:0) CIM_ManagedSystemElement Name Serial number of drive OperationalStatus[0] •...
  • Page 345: Hpscsi_Hbaphysicalpackage

    Table 16-6 Class: HPSCSI_DiskDriveFirmwareIdentity (CIM_SoftwareIdentity) Property name Property implementation ElementName TargetType value—drive model string CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) Description Disk Drive Firmware InstanceID Opaque key Manufacturer Drive vendor IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ:<TargetType value>...
  • Page 346: Hpscsi_Diskphysicalpackage

    Table 16-7 Class: HPSCSI_HBAPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Version N/A—Not available in this implementation. HPSCSI_DiskPhysicalPackage 16-3-7 HPSCSI_DiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive. Table 16-8 Class: HPSCSI_DiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName...
  • Page 347: Hpscsi_Storageenclosureprocessor

    Table 16-9 Class: HPSCSI_StorageEnclosure (CIM_Chassis) Property name Property implementation ElementName Enclosure location (for example, Internal Storage System ) CIM_ManagedSystemElement Name Enclosure index CIM_ PhysicalElement CreationClassName HPSCSI_StorageEnclosure Manufacturer Enclosure vendor string Model Enclosure model string (for example, PROLIANT 4L6I) PartNumber N/A—Not Available in this implementation SerialNumber Enclosure Serial Number Opaque key...
  • Page 348: Hpscsi_Hbaportcontroller

    Table 16-10 Class: HPSCSI_StorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation OperationalStatus Operational status for enclosure and associated power supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows: • OperationalStatus[0]—Enclosure status ○...
  • Page 349: Hpscsi_Daport

    Table 16-11 Class: HPSCSI_HBAPortController (CIM_PortController) Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not applicable) RequestedState 12 (Not applicable) CIM_LogicalDevice CreationClassName HPSCSI_HBAPortController DeviceID Key: HBA index SystemCreationClassName HPSCSI_HBAComputerSystem SystemName HBA index CIM_Controller CIM_PortController ControllerType 1 (Other) OtherControllerType SCSI HPSCSI_DAPort 16-3-11 HPSCSI_DAPort represents the front-end port for an HBA in the host system.
  • Page 350: Hpscsi_Hbaspiport

    Table 16-12 Class: HPSCSI_DAPort (CIM_DAPort) Property name Property implementation CreationClassName HPSCSI_DAPort DeviceID Opaque key SystemCreationClassName HPSCSI_HBAComputerSystem SystemName HBA Index CIM_LogicalPort UsageRestriction 2 (Front-End Only) CIM_DAPort HPSCSI_DAPort HPSCSI_HBASPIPort 16-3-12 HPSCSI_HBASPIPort represents the initiator port to connect to disk drives. Table 16-13 Class: HPSCSI_SPIPort (CIM_SPIPort) Property name Property implementation...
  • Page 351: Hpscsi_Hbafirmwareidentity

    Table 16-13 Class: HPSCSI_SPIPort (CIM_SPIPort) Property name Property implementation UsageRestriction 3 (Back-end Only) CIM_SPIPort MaxDataWidth Max bus width (bits) MaxTransferRate Max rate in bits per second HPSCSI_HBAFirmwareIdentity 16-3-13 HPSCSI_HBAFirmwareIdentity represents the firmware installed on a SCSI HBA controller. Table 16-14 Class: HPSCSI_HBAFirmwareIdentity (CIM_SoftwareIdentity) Property name Property implementation...
  • Page 352: Hpscsi_Mediaaccessstatdata

    Table 16-15 Class: HPSCSI_EnclosureFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedElement Caption Storage Enclosure Firmware ElementName TargetType value CIM_ManagedSystemElement Name Storage Enclosure Firmware CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure Vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ:<TargetType value>...
  • Page 353: Hpscsi_Drivecage

    Table 16-16 Class: HPSCSI_MediaAccessStatData (CIM_MediaAccessStatData) Property name Property implementation SeekErrors See HP SCSI HBA Profile P00123 ServiceHours See HP SCSI HBA Profile P00123 HPSCSI_DriveCage 16-3-16 HPSCSI_DriveCage represents the drive cage assembly and back plane in a storage enclosure. There can be multiple instances within a duplexed enclosure. Table 16-17 Class: HPSCSI_DriveCage (CIM_PhysicalPackage) Property name...
  • Page 354: Hpscsi_Dascsiprotocolendpoint

    Table 16-18 Class: HPSCSI_HBASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation ElementName Controller name and location (for example, SCSI Controller Port 1 in Slot 4) CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint CreationClassName HPSCSI_HBASCSIProtocolEndpoint Name HBA Serial Number SystemCreationClassName HPSCSI_HBAComputerSystem SystemName...
  • Page 355: Hpscsi_Hbascsiprotocolcontroller

    Table 16-19 Class: HPSCSI_DASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation Name HBA Index SystemCreationClassName HPSCSI_HBAComputerSystem SystemName HBA index CIM_ProtocolEndpoint ProtocolIFType 0 (Unknown) CIM_SCSIProtocolEndpoint ConnectionType 3 (Parallel SCSI) Role 2 (Initiator) HPSCSI_HBASCSIProtocolController 16-3-19 HPSCSI_HBASCSIProtocolController represents a view of SCSI resources on the SCSI HBA. This is required to model the presentation of SCSI luns to the host system.
  • Page 356: Hpscsi_Hbagroupcollection

    Table 16-20 Class: HPSCSI_HBASCSIProtocolController (CIM_SCSIProtocolController) Property name Property implementation MaxUnitsControlled CIM_ SCSIProtocolController HPSCSI_HBAGroupCollection 16-3-20 HPSCSI_HBAGroupCollection represents a collection of SCSI HBA controllers that have been grouped together to report a consolidated status. Table 16-21 Class: HPSCSI_HBAGroupCollection (HP_GroupHostedCollection) Property name Property implementation CIM_ManagedElement Caption HP consolidated status for all SCSI HBAs...
  • Page 357: Hpscsi_Drivecagelocation

    Table 16-22 Class: HPSCSI_StorageEnclsoureLocation (HP_Location) Property name Property implementation Description Enclosure location For example, Internal Storage System on Port 1 Name PhysicalPosition ElementLocationTag • External for external enclosures • Internal for drive cages located within the host chassis ElementLocationTagDesc 19 (Box) HPSCSI_DriveCageLocation 16-3-22 HPSCSI_DriveCageLocation represents a location string for the drive cage.
  • Page 358: Hpscsi_Diskdrivelocation

    Table 16-24 Class: HPSCSI_HBALocation (HP_Location) Property name Property implementation ElementName Controller name and location (for example, SCSI Controller Port 1 in Slot 4) Caption Controller name and location For example, SCSI Controller Port 1 in Slot 4 Description Controller name and location For example, SCSI Controller Port 1 in Slot 4 Name PhysicalPosition...
  • Page 359 Table 16-26 Class: HPSCSI_HBAProduct (CIM_Product) Property name Property implementation ElementName Controller name and location (for example, SCSI Controller Port 1 in Slot 4) IdentifyingNumber Key: Opaque key Name Marketing name Vendor Vendor string Version Firmware version HPSCSI_HBAComputerSystemStorageEnclosureProcessor 16-3-26 (Association) Table 16-27 Class: HPSCSI_HBAComputerSystemStorageEnclosureProcessor (CIM_SystemComponent) Property name Property implementation...
  • Page 360: Hpscsi_Hbacomputersystemdiskdrive (Association)

    HPSCSI_HBAComputerSystemDiskDrive (Association) 16-3-29 Table 16-30 Class: HPSCSI_HBAComputerSystemDiskDrive (CIM_SystemDevice) Property name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_DiskDrive HPSCSI_HBAComputerSystemStorageVolume 16-3-30 (Association) Table 16-31 Class: HPSCSI_HBAComputerSystemStorageVolume (CIM_SystemDevice) Property name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_StorageVolume HPSCSI_HBAComputerSystemStorageExtent 16-3-31 (Association) Table 16-32 Class: HPSCSI_HBAComputerSystemStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent...
  • Page 361: Hpscsi_Hbacomponentcs (Association)

    Table 16-34 Class: HPSCSI_HBAComputerSystemDAPort (CIM_SystemDevice) Property name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_DAPort. HPSCSI_HBAComponentCS (Association) 16-3-34 Table 16-35 Class: HPSCSI_HBAComponentCS (CIM_ComponentCS) Property name Property implementation GroupComponent HP_WinComputerSystem PartComponent HPSCSI_HBAComputerSystem HPSCSI_StorageEnclosureStorageEnclosureProcessor 16-3-35 (Association) Table 16-36 Class: HPSCSI_StorageEnclosureStorageEnclosureProcessor (CIM_systemPackaging) Property name Property implementation Antecedent HPSCSI_StorageEnclosure Dependent...
  • Page 362: Hpscsi_Drivecagediskdrive (Association)

    HPSCSI_HBAPhysicalPackageDiskDrivePhysicalPackage 16-3-38 (Association) Table 16-39 Class: HPSCSI_HBAPhysicalPackageDiskDrivePhysicalPackage (CIM_Container) Property name Property implementation GroupComponent HPSCSI_HBAPhysicalPackage PartComponent HPSCSI_DiskPhysicalPackage HPSCSI_DriveCageDiskDrive (Association) 16-3-39 Table 16-40 Class: HPSCSI_DriveCageDiskDrive (CIM_Container) Property name Property implementation GroupComponent HPSCSI_DriveCage PartComponent HPSCSI_DiskPhysicalPackage HPSCSI_HBAComputerSystemHBAFirmwareIdentity 16-3-40 (Association) Table 16-41 Class: HPSCSI_HBAComputerSystemHBAFirmwareIdentity (CIM_InstalledSoftwareIdentity) Property name Property implementation Antecedent...
  • Page 363: Hpscsi_Diskdrivestorageextent (Association)

    HPSCSI_StorageEnclosureProcessorEnclosureFirmware 16-3-42 (Association) Table 16-43 Class: HPSCSI_StorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSCSI_EnclosureFirmware Dependent HPSCSI_StorageEnclosureProcessor ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) HPSCSI_DiskDriveDiskDriveFirmwareIdentity 16-3-43 (Association) Table 16-44 Class: HPSCSI_DiskDriveDiskDriveFirmwareIdentity (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSCSI_DiskDriveFirmwareIdentity Dependent HPSCSI_DiskDrive ElementSoftwareStatus •...
  • Page 364: Hpscsi_Storageextentstoragevolume (Association)

    HPSCSI_StorageExtentStorageVolume (Association) 16-3-46 Table 16-47 Class: HPSCSI_StorageExtentStorageVolume (CIM_BasedOn) Property name Property implementation SystemElement HPSCSI_StorageExtent SameElement HPSCSI_StorageVolume HPSCSI_DAPortSCSIProtocolEndpoint (Association) 16-3-47 Table 16-48 Class: HPSCSI_DAPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent HPSCSI_DAPort Dependent HPSCSI_DASCSIProtocolEndpoint HPSCSI_HBASCSIProtocolEndpointSPIPort (Association) 16-3-48 Table 16-49 Class: HPSCSI_HBASCSIProtocolEndpointSPIPort (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent...
  • Page 365: Hpscsi_Hbasystempackaging (Association)

    Table 16-51 Class: HPSCSI_HBAGroupCollectionHBAComputerSystem (CIM_MemberOfCollection) Property name Property implementation Member HPSCSI_ HBAComputerSystem Collection HPSCSI_HBAGroupCollection HPSCSI_HBASystemPackaging (Association) 16-3-51 Table 16-52 Class: HPSCSI_HBASystemPackaging (CIM_ComputerSystemPackage) Property name Property implementation Antecedent HPSCSI_HBAPhysicalPackage Dependent HPSCSI_HBAComputerSystem HPSCSI_HBAPhysicalPackagePortController 16-3-52 (Association) Table 16-53 Class: HPSCSI_HBAPhysicalPackagePortController (CIM_Realizes) Property name Property implementation Antecedent HPSCSI_HBAPhysicalPackage...
  • Page 366: Hpscsi_Drivecagedrivecagelocation (Association)

    HPSCSI_StorageEnclosureEnclosureLocation 16-3-55 (Association) Table 16-56 Class: HPSCSI_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSCSI_StorageEnclosure PhysicalLocation HPSCSI_StorageEnclosureLocation HPSCSI_DriveCageDriveCageLocation (Association) 16-3-56 Table 16-57 Class: HPSCSI_DriveCageDriveCageLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSCSI_DriveCage PhysicalLocation HPSCSI_DriveCageLocation HPSCSI_DiskPhysicalPackageDiskDriveLocation 16-3-57 (Association) Table 16-58 Class: HPSCSI_DiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element...
  • Page 367: Supported Indications

    Table 16-60 Class: HPSCSI_HBAPortControllerHBASPIPort (CIM_ControlledBy) Property name Property implementation Antecedent HPSCSI_HBAPortController Dependent HPSCSI_HBASPIPort HPSCSI_HBAComputerSystemSCSIProtocolEndpoint 16-3-60 (Association) Table 16-61 Class: HPSCSI_HBAComputerSystemSCSIProtocolEndpoint (CIM_HostedAccessPoint) Property name Property implementation Antecedent HPSCSI_HBAComputerSystem Dependent HPSCSI_DASCSIProtcolEndpoint Supported indications 16-4 Table 16-62 HPSCSI_DeviceIndication: Physical Drive status set to OK Property name Property implementation CIM_Indication...
  • Page 368 Table 16-62 HPSCSI_DeviceIndication: Physical Drive status set to OK Property name Property implementation EventCategory 6 (Primary Storage) ProbableCause 59 (Previous event cleared) ProbableCauseDescription Physical Drive OK ProviderVersion 2.2.0.0 NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType •...
  • Page 369 Table 16-62 HPSCSI_DeviceIndication: Physical Drive status set to OK Property name Property implementation HWSerialNumber Disk Serial Number HP_DeviceIndication DeviceModel Disk Model string Table 16-63 HPSCSI_DeviceIndication: Physical Drive status set to ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity Severity (for example, 5 (Major)) IndicationTime...
  • Page 370 Table 16-63 HPSCSI_DeviceIndication: Physical Drive status set to ERROR Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
  • Page 371 Table 16-64 HPSCSI_DeviceIndication: Physical Drive status is set to Predictive Failure Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description SCSI physical drive status is now set to predictive failure. AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert)
  • Page 372 Table 16-64 HPSCSI_DeviceIndication: Physical Drive status is set to Predictive Failure Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName *...
  • Page 373 Table 16-65 HPSCSI_DeviceIndication: Physical Drive status OFFLINE Property name Property implementation RecommendedActions Replace this drive. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary The physical drive is offline. EventCategory 6 (Primary Storage) ProbableCause...
  • Page 374 Table 16-65 HPSCSI_DeviceIndication: Physical Drive status OFFLINE Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Disk firmware version string HWLogicalLocation Disk Location string HWManufacturer Disk Manufacturer string HWSerialNumber Disk Serial Number HP_DeviceIndication...
  • Page 375 Table 16-66 HPSCSI_DeviceIndication: Physical Drive status - Missing was OK Property name Property implementation NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 376 Table 16-67 HPSCSI_DeviceIndication: Physical Drive status - Missing was FAILED Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A physical drive that was located in the system and had a status of failed has been removed AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance...
  • Page 377 Table 16-67 HPSCSI_DeviceIndication: Physical Drive status - Missing was FAILED Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
  • Page 378 Table 16-68 HPSCSI_DeviceIndication: Physical Drive status - Missing was Predictive Failure Property name Property implementation EventID ProviderName SCSIHBA RecommendedActions Check for this disk to have been removed SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary...
  • Page 379 Table 16-68 HPSCSI_DeviceIndication: Physical Drive status - Missing was Predictive Failure Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Disk firmware version string...
  • Page 380 Table 16-69 HPSCSI_DeviceIndication: Physical Drive status – Missing was OFFLINE Property name Property implementation ProviderVersion 2.2.0.0 NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 381 Table 16-70 HPSCSI_DeviceIndication: Controller status changed to Unknown Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 0 (unknown) IndicationTime Time of indication CIM_AlertIndication Description Controller The SCSI device has changed to a status of Unknown AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class instance AlertingElementFormat...
  • Page 382 Table 16-70 HPSCSI_DeviceIndication: Controller status changed to Unknown Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
  • Page 383 Table 16-71 HPSCSI_DeviceIndication: Controller status OK Property name Property implementation AlertType 5 (Device Alert) EventID ProviderName SCSIHBA RecommendedActions No action is necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary SCSI HBA status OK...
  • Page 384 Table 16-71 HPSCSI_DeviceIndication: Controller status OK Property name Property implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion...
  • Page 385 Table 16-72 HPSCSI_DeviceIndication: Controller status ERROR Property name Property implementation ProbableCauseDescription SCSI HBA Status Changed to Error ProviderVersion 2.2.0.0 NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 •...
  • Page 386 Table 16-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description This SCSI Storage enclosure power supply was redundant but due to a failure is not longer redundant AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance...
  • Page 387 Table 16-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain •...
  • Page 388 Table 16-74 HPSCSI_DeviceIndication: Power Supply status OK Property name Property implementation AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID ProviderName SCSIHBA RecommendedActions No action is necessary SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 389 Table 16-74 HPSCSI_DeviceIndication: Power Supply status OK Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 390 Table 16-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED Property name Property implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary SCSI Storage enclosure redundant power supply degraded. EventCategory 17 (Primary Storage Power) ProbableCause 89 (Power Supply Failure) ProbableCauseDescription...
  • Page 391 Table 16-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Enclosure firmware version string HWLogicalLocation Enclosure Location string HWManufacturer Enclosure Manufacturer string HWSerialNumber Enclosure Serial Number HP_DeviceIndication...
  • Page 392 Table 16-76 HPSCSI_DeviceIndication: Temperature sensor status change OK Property name Property implementation NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 64-bit: 70 • For Windows 2008 64-bit: 77 OSVersion Operating system version of the computer system generating the indication in the format,...
  • Page 393 Table 16-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 4 (Minor) IndicationTime Time of indication CIM_AlertIndication Description The SCSI Storage enclosure temperature is outside of normal operating range AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance...
  • Page 394 Table 16-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
  • Page 395 Table 16-78 HPSCSI_DeviceIndication: Temperature sensor status change—Critical Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID ProviderName SCSIHBA RecommendedActions Ensure that the fans are spinning and check the room temperature SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 396 Table 16-78 HPSCSI_DeviceIndication: Temperature sensor status change—Critical Property name Property implementation EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 397 Table 16-79 HPSCSI_DeviceIndication: Fan status change—OK Property name Property implementation EventCategory 24 (Primary Storage Cooling) ProbableCause ProbableCauseDescription Fan Status Changed to OK ProviderVersion 2.2.0.0 NetworkAddresses A list of all the IP addresses of the computer system generating the indication OSType •...
  • Page 398 Table 16-79 HPSCSI_DeviceIndication: Fan status change—OK Property name Property implementation HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string Table 16-80 HPSCSI_DeviceIndication: Fan status change—Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 4 (Minor) IndicationTime Time of indication CIM_AlertIndication Description...
  • Page 399 Table 16-80 HPSCSI_DeviceIndication: Fan status change—Degraded Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication...
  • Page 400 Table 16-81 HPSCSI_DeviceIndication: Fan status change - ERROR Property name Property implementation CIM_AlertIndication Description A fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool. AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 (CIMObjectPath) AlertType...
  • Page 401 Table 16-81 HPSCSI_DeviceIndication: Fan status change - ERROR Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name...
  • Page 402: System Software

    System software Overview 17-1 This provider implements the DMTF Software Inventory profile to support inventory of HP installed software on Integrity systems. The following profiles are implemented and files are installed by this provider. Table 17-1 Overview Implemented Profiles DMTF Software Inventory Profile 1.0 Provider Installation Files HPWmiSys.DLL Use cases...
  • Page 403 (UninstalledInActive) Name Name reported by the software identity CIM_SoftwareIdentity InstanceID Unique identifier for software identity instance Classifications 0x8000 (Hewlett-Packard Software) ClassificationDescriptions Hewlett-Packard Software Manufacturer Hewlett-Packard InstallDate Indicates install date for software identity. If software is not installed, this will indicate the current time and date.
  • Page 404: Cim_Installedsoftwareidentity

    Table 17-2 Class: CIM_SoftwareIdentity Property name Property implementation VersionString Version of the software identity as reported by its underlying instrumentation. If this version can be represented in the following format: MM.mm.rr.bb, where integers MM is MajorVersion, mm is MinorVersion, rr is RevisionNumber, and bb is BuildNumber, then VersionString is set to “”, and MajorVersion, MinorVersion, RevisionNumber and BuildNumber...
  • Page 405: Supported Indications

    Supported indications 17-4 There are no indications produced for the software inventory profile implementation. 16BSystem software 405...
  • Page 406: Profile Registration

    Profile registration Overview 18-1 The following profiles are implemented and files are installed by this provider. Table 18-1 Overview Implemented Profiles HP Profile Registration Profile (P00100) Provider Installation Files • HPWmiProfile.dll • HPWmiProfile.mof Use cases 18-2 For use cases, see the HP Profile Registration profile (P00100). Class implementations 18-3 The following classes describe registration of HP profiles.
  • Page 407 Table 18-2 Class: CIM_RegisteredProfile Property name Property implementation RegisteredName See Tables 17-3 and 17-4 RegisteredOrganization • 2 (DMTF) for DMTF profiles • 11 (SNIA) for SNIA SMI-S storage profiles RegisteredVersion See Tables 17-3 and 17-4 Table 18-3 Property Values of CIM_RegisteredProfile for DMTF Profiles RegisteredName Registered Version InstanceID...
  • Page 408: Hp_Registeredprofile

    Table 18-4 Property Values of CIM_RegisteredProfile for SNIA Profiles RegisteredName Registered Version InstanceID Caption/Description/ ElementName Software 1.2.0 SNIA:Software:120 SNIA Software Profile Extent Mapping 1.0.2 SNIA:ExtentMapping:102 SNIA Extent Mapping Profile Physical Package 1.2.0 SNIA:PhysicalPackage:12 SNIA Physical Package Profile HP_RegisteredProfile 18-3-2 HP_RegisteredProfile extends the class CIM_RegisteredProfile and describes an implemented HP profile.
  • Page 409: Hp_Extendsprofile

    Table 18-6 Property Values of HP_RegisteredProfile for HP WBEM TC Profiles RegisteredName Registered Version InstanceID Caption/Description/ ElementName HP Power Supply 1.0.0 HP:Power Supply HP Power Supply Profile HP Record Log 1.0.0 HP:Record Log HP Record Log Profile HP Sensors 1.0.0 HP:Sensors HP Sensors Profile HP Memory...
  • Page 410: Hp_Referencedprofile

    Table 18-7 Class: HP_ExtendsProfile Property name Property implementation Antecedent ref: CIM_RegisteredProfile (extended) Dependent ref: HP_RegisteredProfile (extends) HP_ReferencedProfile 18-3-4 HP_ReferencedProfile extends the class CIM_ ReferencedProfile and associates an HP profile that references another profile when both are registered in the root\Interop namespace. The following properties are implemented.
  • Page 411: For More Information

    For more information • http://www.dmtf.org • http://www.snia.org • http://www.hp.com 18BFor more information 411...

This manual is also suitable for:

Integrity rx8620Integrity superdome sx1000

Table of Contents