HP Rp3440-4 - 9000 - 0 MB RAM Installation Manual

Installation guide, seventh edition - hp 9000 rp3410 and hp 9000 rp3440
Hide thumbs Also See for Rp3440-4 - 9000 - 0 MB RAM:
Table of Contents

Advertisement

Quick Links

Installation Guide

HP 9000 rp3410 and HP 9000 rp3440
Manufacturing Part Number: A7137-96007
Seventh Edition
April 2007
Printed in the US

Advertisement

Table of Contents
loading

Summary of Contents for HP Rp3440-4 - 9000 - 0 MB RAM

  • Page 1: Installation Guide

    Installation Guide HP 9000 rp3410 and HP 9000 rp3440 Manufacturing Part Number: A7137-96007 Seventh Edition April 2007 Printed in the US...
  • Page 2: Legal Notices

    Legal Notices Copyright Notices. © Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services.
  • Page 3: Table Of Contents

    Contents About This Document 1. Installing the System Introduction ............... . 13 Server Views .
  • Page 4 Contents Additional Setup ..............76 Accessing the Host Console .
  • Page 5 Tables Table 1. Publishing History Details ........... 9 Table 2.
  • Page 6 Tables...
  • Page 7 Figures Figure 1-1. HP 9000 rp3410/rp3440 Server (Front View) ....... . . 14 Figure 1-2.
  • Page 8 Figures Figure 1-44. Locking the Dual Processor Module in Place ....... . 58 Figure 1-45.
  • Page 9: About This Document

    About This Document This document describes how to unpack the HP 9000 rp3410/rp3440 server, install additional components, start a server console session, power on the server, and boot the operating system. The document printing date and part number indicate the document’s current edition. The printing date changes when a new edition is printed.
  • Page 10: Document Organization

    Table 1 Publishing History Details (Continued) Document Operating Systems Manufacturing Supported Product Versions Publication Date Supported Part Number A7137-96001 HP-UX 11i v1 HP 9000 rp3410 and rp3440 April 2005 HP-UX 11i v1 HP 9000 rp3410 and rp3440 July 2004 Document Organization This guide is divided into the following sections.
  • Page 11: Table 2. Hp-Ux 11I Releases

    Tips provide you with helpful hints for completing a task. A tip is not used to give essential information, but can be used, for example, to provide an alternate method for completing the task that precedes it. Book Title The title of a book. On the Web and on the Instant Information CD, it may be a hot link to the book itself.
  • Page 12: Hp Encourages Your Comments

    Server Hardware Information: http://docs.hp.com/hpux/hw/ Diagnostics and Event Monitoring: Hardware Support Tools Complete information about HP’s hardware support tools, including online and offline diagnostics and event monitoring tools, is at the http://docs.hp.com/hpux/diag/ Web site. This site has manuals, tutorials, FAQs, and other reference material. Web Site for HP Technical Support: http://us-support2.external.hp.com/ Books about HP-UX Published by Prentice Hall...
  • Page 13: Installing The System

    Installing the System This chapter provides information on how to install the system. This chapter addresses the following topics: • “Introduction” on page 13 • “Unpacking and Inspecting the Server” on page 22 • “Installing Additional Components” on page 25 •...
  • Page 14: Server Views

    Installing the System Introduction Server Views Figure 1-1, Figure 1-2, Figure 1-3, and Figure 1-4 show the front, rear, and pedestal-mount views of the HP 9000 rp3410 and rp3440 servers. Figure 1-1 HP 9000 rp3410/rp3440 Server (Front View) Figure 1-2 HP 9000 rp3410/rp3440 Server (Front View with Bezel Removed) Figure 1-3 HP 9000 rp3410/rp3440 Server (Rear View)
  • Page 15: Figure 1-4 Hp 9000 Rp3410/Rp3440 Server (Pedestal Mount)

    Installing the System Introduction Figure 1-4 HP 9000 rp3410/rp3440 Server (Pedestal Mount) Chapter 1...
  • Page 16: Detailed Server Description

    Installing the System Introduction Detailed Server Description The following sections list the main subsystems within the HP 9000 rp3410 and rp3440 servers. Features Table 1-1 lists the features of the HP 9000 rp3410 and rp3440 servers. Table 1-1 HP 9000 rp3410 and rp3440 Server Features Features rp340 rp3440...
  • Page 17: Safety Information

    Installing the System Introduction Firmware Firmware consists of many individually linked binary images that are bound together by a single framework at run time. Internally, the firmware employs a software database called a device tree to represent the structure of the hardware platform and to provide a means of associating software elements with hardware functionality.
  • Page 18: Control Panel

    Installing the System Introduction • If installing a hot-pluggable component, complete the required software intervention prior to removing the component. • If installing an assembly that is neither hot-swappable, nor hot-pluggable, disconnect the power cable from the external server power receptacle. WARNING Ensure that the server is powered off and all power sources are disconnected from the server prior to removing or installing server hardware unless you are removing...
  • Page 19: Additional Controls And Indicators

    Installing the System Introduction Figure 1-6 Control Panel Locator Button and LED Power Button Diagnostics LEDs Power System (Disabled) On/Off LED LAN System Additional Controls and Indicators The HP 9000 rp3410 or HP 9000 rp3440 server can have up to three low-voltage differential (LVD), 3.5 inch form factor hard disk drives (HDDs) installed.
  • Page 20: Rear Panel

    Installing the System Introduction Optional Removable Media Drive The HP 9000 rp3410 or rp3440 server is delivered without a removable media drive. Either a DVD or CD-RW/DVD, drive may be added. Each of these optional devices has one activity LED. Figure 1-8 DVD–ROM or CD-RW/DVD-ROM LED Indicators Activity...
  • Page 21: Table 1-5. Rear Panel Connectors And Switches

    Installing the System Introduction Figure 1-9 Rear View VGA Port-disabled System Lock DO NOT USE Console/Remote/UPS ac Power Receptacle Console/Serial Port A (factory use only) PCI Slot 1 PCI Slot 2 PCI Slot 3 (rp3440 only) PCI Slot 4 LVD/SE SCSI USB Ports Serial Port B (rp3440...
  • Page 22: Installation Sequence And Checklist

    Installing the System Unpacking and Inspecting the Server Installation Sequence and Checklist Follow the steps in Table 1-6 sequentially to ensure successful installation of the server. Table 1-6 Installation Sequence Checklist Step Description Completed Unpack and inspect the server shipping container; inventory the contents using the packing slip.
  • Page 23: Inspecting The Shipping Containers For Damage

    Installing the System Unpacking and Inspecting the Server Inspecting the Shipping Containers for Damage HP shipping containers protect their contents under normal shipping conditions. After the equipment arrives, carefully inspect each carton for signs of shipping damage. Shipping damage constitutes moderate to severe damage, such as punctures in the corrugated carton, crushed boxes, or large dents.
  • Page 24 Installing the System Unpacking and Inspecting the Server Step 3. Break off any foam packaging which could prevent the lifter from being fully inserted under the server. Do not remove the foam packaging from the corners of the server. This foam is required to elevate the server and enable the forks of the lifter to be placed under the server.
  • Page 25: Installing Additional Components

    Installing the System Installing Additional Components Installing Additional Components This section describes how to install server components that are not installed before delivery. Removing and Replacing Server Covers and Bezels To upgrade, remove, or replace most server components, you must first remove the covers from the server chassis.
  • Page 26: Figure 1-10 Release The Rack Latches

    Installing the System Installing Additional Components Figure 1-10 Release the Rack Latches Step 3. Slide the server out of the rack until the guide-rail release clips are visible. Insert the Server into the Rack To insert the server into the rack, follow these steps: Step 1.
  • Page 27: Figure 1-11 Removing And Replacing The Top Cover On A Rack-Mounted Server

    Installing the System Installing Additional Components Figure 1-11 Removing and Replacing the Top Cover on a Rack-Mounted Server Step 3. Lift the cover off the server chassis. Replacing the Top Cover on a Rack-Mounted Server CAUTION Secure any wires or cables in the server so they will not get cut or interfere with the replacement of the cover.
  • Page 28: Figure 1-13 Closing The Top Cover

    Installing the System Installing Additional Components Step 2. Grasp the blue release lever and slide the cover toward the front of the server until the lever snaps into place. Figure 1-13 Closing the Top Cover Step 3. Slide the server into the rack enclosure and reconnect the power and external cables. Removing and Replacing the Front Bezel on a Rack-Mounted Server You must remove the front bezel from the chassis to gain access to the power supplies and optical drive.
  • Page 29: Figure 1-15 Replacing The Front Bezel

    Installing the System Installing Additional Components Step 2. Rotate the front panel outward and lift it off the server chassis. Replacing the Front Bezel on a Rack-Mounted Server Step 1. Insert the bezel latches into the matching slots on the server chassis. Step 2.
  • Page 30: Figure 1-16 Removing The Side Cover On A Pedestal-Mounted Server

    Installing the System Installing Additional Components Figure 1-16 Removing the Side Cover on a Pedestal-Mounted Server Removing the Top Cover on Pedestal-Mounted Server To remove the top cover, follow these steps: Step 1. Turn the top cover lock keyswitch to the unlocked position. Step 2.
  • Page 31: Figure 1-17 Removing The Top Cover On A Pedestal-Mounted Server

    Installing the System Installing Additional Components Figure 1-17 Removing the Top Cover on a Pedestal-Mounted Server Step 4. Remove the top cover. CAUTION The server depends on the access panels being closed for proper cooling of internal components. Operating the server with the cover removed can cause the server to quickly overheat.
  • Page 32: Figure 1-18 Top Cover Alignment Mark

    Installing the System Installing Additional Components Figure 1-18 Top Cover Alignment Mark To replace cover, align front edge here then slide forward Step 2. Place the top cover on the chassis and slide it toward the front of the server until the blue release lever snaps in place.
  • Page 33: Figure 1-20 Replacing The Side Cover On A Pedestal-Mounted Server

    Installing the System Installing Additional Components Figure 1-20 Replacing the Side Cover on a Pedestal-Mounted Server Step 2. Close the cover until it snaps onto the server chassis. Removing and Replacing Front Bezel on a Pedestal-Mounted Server You must remove the front bezel from the chassis to gain access to the power supplies and optical drive. Removing the Front Bezel on a Pedestal-Mounted Server To remove the front bezel parts, follow these steps: Step 1.
  • Page 34: Figure 1-21 Removing The Front Bezel On A Pedestal-Mounted Server

    Installing the System Installing Additional Components Figure 1-21 Removing the Front Bezel on a Pedestal-Mounted Server Step 2. Lift the bezel off the mounting tabs and away from the chassis. Replacing the Front Bezel on a Pedestal-Mounted Server To replace the front bezel parts, follow these steps: Step 1.
  • Page 35: Installing Internal Hard Disk Drives

    Installing the System Installing Additional Components Figure 1-22 Aligning the Pedestal Front Bezel Step 2. Rotate the bezel against the chassis so that it snaps into place. Installing Internal Hard Disk Drives This section provides information about installing additional internal hard disk drives. CAUTION A hot-pluggable device can require interaction with the operating server before the device can be safely installed into the server.
  • Page 36: Figure 1-23. Front View Of The Hp 9000 Rp3410/Rp3440 Server

    Installing the System Installing Additional Components Figure 1-23 Front View of the HP 9000 rp3410/rp3440 Server Control Panel DVD Drive LVD HDD 3 System Product Label (pull-out) LVD HDD 2 LVD HDD 1 Two additional hard disk drives can be added to the server in slots 2 and 3. Always use low profile disk drives (1 inch height) in HP 9000 rp3410 and rp3440 servers.
  • Page 37: Figure 1-24. Filler Removal From Slot 1

    Installing the System Installing Additional Components Figure 1-24 Filler Removal from Slot 1 Step 3. Slide the hard disk drive into the slot until it is seated. Figure 1-25 Disk Drive Installation in Slot 3 Step 4. Close the drive ejector handle by pushing it down until it clicks. Step 5.
  • Page 38: Figure 1-26 Hard Drive Lock

    Installing the System Installing Additional Components a. Press the hard drive locking lever down into the locked position. b. Replace the cover and bezel. (See “Removing and Replacing Server Covers and Bezels” on page 25.) Figure 1-26 Hard Drive Lock Step 6.
  • Page 39: Installing A Dvd Drive

    Installing the System Installing Additional Components Installing a DVD Drive Install a DVD drive behind the front bezel. Ensure that the server is powered off and all power sources have been disconnected WARNING from the server prior to removing or replacing a removable media drive. Voltages are present at various locations within the server whenever an ac power source is connected.
  • Page 40: Removing And Replacing Airflow Guides

    Installing the System Installing Additional Components Installing the DVD Drive To install a DVD drive, follow these steps: Step 1. Power off the server and disconnect power and external cables. Step 2. Remove the front bezel and cover. (See “Removing and Replacing Server Covers and Bezels” on page 25.) Step 3.
  • Page 41: Figure 1-28 Airflow Guides Locations

    Installing the System Installing Additional Components Figure 1-28 Airflow Guides Locations Processor Airflow Guide Memory Airflow Guide Front Portion of Processor Airflow Guide Removing and Replacing the Memory Airflow Guide Removing the Memory Airflow Guide Step 1. Power off the server and disconnect power and external cables. Step 2.
  • Page 42: Figure 1-30 Removing The Processor Airflow Guide

    Installing the System Installing Additional Components Replacing the Memory Airflow Guide Step 1. Align the guides on both sides of the airflow guide with the slots on the chassis. Step 2. Insert the memory airflow guide in the slots. Step 3. Replace the cover. (See “Removing and Replacing the Top Cover on a Rack-Mounted Server” on page 26.) Removing and Replacing the Processor Airflow Guide Removing the Processor Airflow Guide...
  • Page 43: Figure 1-31 Removing Fans 1A And 1B

    Installing the System Installing Additional Components Figure 1-31 Removing Fans 1A and 1B Fan 1A Fan 1B Step 6. Grasp system fan 1B and lift it from its socket (Figure 1-31). Step 7. Remove the memory airflow guide. “Removing the Memory Airflow Guide” on page 41 Step 8.
  • Page 44: Figure 1-32 Open The Release Clip

    Installing the System Installing Additional Components Figure 1-32 Open the Release Clip Step 9. Disconnect the power cable connected to the guide from the system board by squeezing the clips. Step 10. Lift the front portion of the processor airflow guide out of the server. Figure 1-33 Remove the Front Portion of the Processor Airflow Guide Chapter 1...
  • Page 45: Figure 1-34 Routing The Turbofan Power Cables Through Heatsink Posts

    Installing the System Installing Additional Components Replacing the Processor Airflow Guide Step 1. Replace the front portion of the airflow guide: a. Align the release latch of the front half of the airflow guide over the release latch post and snap it in place.
  • Page 46: Installing Additional System Memory

    Installing the System Installing Additional Components Installing Additional System Memory The server has 12 memory sockets for installing DDR SDRAM memory modules. System memory DIMMs are located on the system board. Ensure that the server is powered off and all power sources have been disconnected WARNING from the server prior to removing or replacing system memory.
  • Page 47: Figure 1-35 Dimm Slot Identification

    Installing the System Installing Additional Components Figure 1-35 DIMM Slot Identification Rear Pair 6 (5A&5B) Pair 4 (3A&3B) Pair 2 (1A&1B) Cell 1 Cell 0 Pair 1 (0A&0B) Quad 1 = Pair 1 & Pair 2 Pair 3 (2A & Quad 2 = Pair 3 &...
  • Page 48 Installing the System Installing Additional Components Memory Loading Rules and Performance Guidelines • DIMMs must be installed in server load sequence (the first DIMM must be in the first slot, the second DIMM must be in the second slot, and so on). •...
  • Page 49 Installing the System Installing Additional Components In order to use the chip spare functionality, only DIMMs built with x4 SDRAM parts can be used, and these DIMMs must be loaded in quads (two DIMMs per memory cell, loaded in the same location in each memory cell).
  • Page 50: Removing And Replacing The Pci Card Cage

    Installing the System Installing Additional Components Figure 1-36 Inserting DIMM into Connector Step 6. Replace the memory airflow guide. (See “Replacing the Memory Airflow Guide” on page 42.) Step 7. Replace the server cover. (See “Removing and Replacing the Top Cover on a Rack-Mounted Server” on page 26.) Step 8.
  • Page 51: Figure 1-37 Removing The Pci Card Cage

    Installing the System Installing Additional Components Step 3. Lift up on the PCI card cage release lever and the back edge of the PCI card cage and lift the PCI card cage out of the server. Figure 1-37 Removing the PCI Card Cage Step 4.
  • Page 52: Installing Pci Cards

    Installing the System Installing Additional Components Figure 1-38 Removing the PCI Card Cage Cover Step 5. Unscrew the bulkhead screw that holds the accessory card holder (if installed) in place. Step 6. The PCI slots are now accessible for installation of additional cards. Replacing the PCI Card Cage To replace the PCI card cage, follow these steps: Step 1.
  • Page 53: Figure 1-39 Installing A Pci Card

    Installing the System Installing Additional Components Failure to observe this warning can result in personal injury or damage to equipment. CAUTION Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD safety precautions can result in damage to the server. Carefully read the following information concerning PCI slot configuration.
  • Page 54: Installing An Additional Power Supply

    Installing the System Installing Additional Components Step 8. Verify the PCI card installation by using the system utilities. • Use the iLO MP commands to verify operation. • Use the BCH commands to verify operation. • Use diagnostics provided by the offline diagnostic environment to exercise the card added. Installing an Additional Power Supply The supported configuration of the HP 9000 rp3410 and rp3440 servers requires a minimum of one power supply to be installed.
  • Page 55: Installing An Additional Processor Module

    Installing the System Installing Additional Components Figure 1-41 Replacing the Power Supply Power Supply Power Supply 1 Step 4. Push in on the power supply release lever to lock the retaining clip in place. Step 5. Replace the front bezel. (See “Removing and Replacing Front Bezel on a Pedestal-Mounted Server” on page 33.) Step 6.
  • Page 56: Figure 1-42 Unlocking The Dual Processor Module Locking Mechanism

    Installing the System Installing Additional Components Failure to properly complete the steps in this procedure will result in erratic server behavior or CAUTION system failure. For assistance with this procedure contact your local HP Authorized Service Provider. Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD safety precautions can result in damage to the server.
  • Page 57: Figure 1-43 Aligning The Processor Module

    Installing the System Installing Additional Components Protective covers can be installed to protect connector pins. These covers can be NOTE saved for future use. Step 7. Use the four locator posts on the heatsink and the turbo fan power cable to properly align the fan and dual processor module on the system board.
  • Page 58: Figure 1-44 Locking The Dual Processor Module In Place

    Installing the System Installing Additional Components Figure 1-44 Locking the Dual Processor Module in Place CPU Install Tool (2.5 mm Driver/Allen Wrench) Step 9. Slide the sequencing retainer plate toward the front of the server. Figure 1-45 Slide the Sequencing Retainer Plate Step 10.
  • Page 59: Figure 1-46 Secure The Captive Screws

    Installing the System Installing Additional Components Figure 1-46 Secure the Captive Screws CPU Install Tool (Torx T15) Step 11. Locate the two power pod module shims on the system board. (On servers delivered with only one dual processor module installed, the power module shims are held in place by screws with plastic spacers over the threads.) Remove the holding screws and discard the plastic spacers.
  • Page 60: Figure 1-48 Aligning The Processor Module Power Pod

    Installing the System Installing Additional Components Figure 1-48 Aligning the Processor Module Power Pod Step 13. Align the two mounting screw holes on the power pod module with the screw holes in the shims on the system board’s metal mounting bracket. Screw in the power pod module mounting screws. (Use the screws removed in step 11.) Chapter 1...
  • Page 61: Figure 1-49 Install The Processor Module Power Pod Mounting Screws

    Installing the System Installing Additional Components Figure 1-49 Install the Processor Module Power Pod Mounting Screws Step 14. Connect the power pod cable to the power connector on the system board. Chapter 1...
  • Page 62: Figure 1-50 Connecting The Power Pod Cable

    Installing the System Installing Additional Components Figure 1-50 Connecting the Power Pod Cable Chapter 1...
  • Page 63: Figure 1-51 Routing The Turbofan Power Cables Through Heatsink Posts

    Installing the System Installing Additional Components CAUTION Turbo fan power cables can be damaged if pinched between the heatsink posts and the processor airflow guide. Ensure that the cables are below the top surface of the heatsink posts before installing the processor airflow guide. Step 15.
  • Page 64: Replacing The System Battery

    Installing the System Installing Additional Components Replacing the System Battery The server has two batteries. The main system battery is located on the system board. The other battery is located on the underside of the iLO MP card. Battery Notice This product contains a Lithium battery (HP part number 1420-0386).
  • Page 65: Figure 1-52 Replacing The System Battery

    Installing the System Installing Additional Components Figure 1-52 Replacing the System Battery Step 7. Replace the cover. (See “Removing and Replacing Server Covers and Bezels” on page 25 for instructions.) Step 8. Reconnect power and external cables and turn on the server. Step 9.
  • Page 66: Installing The Server Into A Rack, Non-Hp Rack, Or Pedestal

    Installing the System Installing the Server Into a Rack, Non-HP Rack, or Pedestal Installing the Server Into a Rack, Non-HP Rack, or Pedestal The following information describes how to install the server into an HP rack. Information is also provided on approved non-HP rack and pedestal-mounted alternatives.
  • Page 67: Connecting The Cables

    Installing the System Connecting the Cables Connecting the Cables This section describes the cables to connect to power the server and to provide LAN connectivity for the server. AC Input Power The server comes with one or two power supplies installed. A power supply includes an ac input connector which is rated for 200 to 240 VAC at 13 amps.
  • Page 68: Applying Standby Power To The Server

    Installing the System Connecting the Cables Applying Standby Power to the Server To apply standby power to the server, follow these steps: Step 1. If the server has one power supply installed in slot P1, plug the power cord into that receptacle. Plug the other end of the power cord into an appropriate outlet.
  • Page 69: Console Setup

    Installing the System Console Setup Console Setup This section describes how to set up and start a console session on the server and includes the following steps: • Determine the physical access method to connect cables. There are two physical connections to the iLO —...
  • Page 70: Setup Flowchart

    Installing the System Console Setup Setup Flowchart Use this flowchart as a guide to assist in the iLO MP setup process. Figure 1-54 iLO MP Setup Flowchart and IP address and IP address Chapter 1...
  • Page 71: Preparation

    Installing the System Console Setup Preparation You must perform the following tasks before you can configure the iLO MP LAN. • Determine the physical access method to select and connect cables. • Determine the iLO MP LAN configuration method and assign an IP address if necessary. Determining the Physical iLO MP Access Method Before you can access the iLO MP, you must first determine the correct physical connection method.
  • Page 72: Configuring The Ilo Mp Lan Using Dhcp And Dns

    Installing the System Console Setup Table 1-9 LAN Configuration Methods (Continued) RS-232 Serial Port DHCP LAN Configuration Method (iLO MP LC command) ARP Ping ARP Ping, RS-232 serial port, or remote/modem port RS-232 serial port, or remote/modem port RS-232 serial port, remote/modem port, or ARP Ping Cannot set up the LAN.
  • Page 73: Table 1-10 Arp Ping Commands

    Installing the System Console Setup ARP Ping operational issues include the following: • You can use ARP Ping regardless of the status of DHCP, unless an IP address has ever been acquired using DHCP • When ARP Ping is successful, DHCP status is disabled •...
  • Page 74: Configuring The Ilo Mp Lan Using The Rs-232 Serial Port

    Installing the System Console Setup For example: arp -s 192.0.2.1 00-00-0c-07-ac-00 Step 6. At the DOS prompt, enter ping followed by the IP address to verify that the iLO MP LAN port is configured with the appropriate IP address. The destination address is the IP address that is mapped to the MP MAC address.
  • Page 75 Installing the System Console Setup IMPORTANT Do not use hpterm and vt100 terminal types at the same time. There are many different emulation software applications. Consult the help section of your emulation software application for instructions on how to configure the software options. Step 3.
  • Page 76: Logging In To The Ilo Mp

    Installing the System Console Setup Logging In to the iLO MP To log in to the iLO MP, follow these steps: Step 1. Access the iLO MP using the LAN, RS-232 serial port, telnet, SSH, or Web method. The iLO MP login prompt displays.
  • Page 77 Installing the System Console Setup To modify default account configuration settings, follow these steps: Step 1. Log in as the administrator. You must log in as the administrator in order to modify default user configuration settings. Step 2. To modify default passwords, follow these steps: a.
  • Page 78: Accessing The Host Console

    Installing the System Accessing the Host Console Accessing the Host Console This section describes the different ways to access the host console of the server. Accessing the Host Console With the TUI - CO Command This section describes the steps to access the host console using the text user interface (TUI). To access the host console through the iLO MP, follow these steps: Step 1.
  • Page 79: Accessing The Graphic Console Using Vga

    Installing the System Accessing the Host Console Step 3. Click . The page displays after login. Sign In Status Summary Figure 1-56 Status Summary Page Function Tabs Navigation Bar Display Screen Step 4. Select the Web interface functions by clicking the tabs at the top of the page.
  • Page 80: Powering On And Powering Off

    Installing the System Powering ON and Powering OFF IMPORTANT The server console output does not display on the console device screen until the server boots to the BCH . Start a console session using the RS-232 serial port method to view console Main Menu output prior to booting to the BCH or to access the iLO MP.
  • Page 81: Powering On The Server

    Installing the System Powering ON and Powering OFF If the power restore feature is set to Always On through the iLO MP PR command, the server NOTE automatically powers on to the full power state when the power cord is plugged in to the server. Powering On the Server Power on the server to full power using the following methods if the server is in the standby power state: •...
  • Page 82: Booting The Operating System

    Installing the System Booting the Operating System Step 1. Gracefully shut down the operating system. Step 2. Initiate a console session, and access the MP Main Menu Step 3. Enter CM to enable command mode. Step 4. Enter PC to use the remote power control command. Step 5.
  • Page 83 Installing the System Booting the Operating System • To shut down the HP-UX operating system, see “Shutting Down HP-UX” on page 83. Standard HP-UX Booting Using Boot Console Handler To the autoboot function is enabled, the server boots to the installed operating system. If autoboot is not enabled, the server enters the boot console handler (BCH).
  • Page 84: Verifying The Server Configuration Using Boot Console Handler

    Installing the System Booting the Operating System For details, see the shutdown (1M) manpage and follow these steps: Step 1. From the HP-UX command line, issue the shutdown command to shut down the HP-UX operating system. Step 2. Log in to HP-UX running on the server that you want to shut down. You should log in to the iLO MP for the server and use the menu to access the server Console...
  • Page 85: Troubleshooting

    Installing the System Troubleshooting Troubleshooting This section provides basic server troubleshooting information. It is designed to help you diagnose common issues that can occur during server installation. Troubleshooting Methodology The server was tested prior to shipping. Failures encountered during installation can be due to damage that occurred in transit.
  • Page 86: Server Does Not Power On

    Installing the System Troubleshooting Table 1-13 describes what happens when the server is on with the operating system running, and you press the power button. Table 1-13 Server Power Button Functions When Server is On and OS is Running Action Reaction One to three seconds System power turns off (software controlled power off).
  • Page 87: Operating System Boots With Problems

    Installing the System Troubleshooting • Offline Diagnostic Environment (ODE) Operating System Boots with Problems If the operating system is running and you are experiencing problems, use the following tools to help solve the problem: • LEDs • Error Messages and event logs Intermittent Server Problems You can usually trace intermittent problems that occur during installation to power source problems, a loose connector, or some other hardware problem.
  • Page 88: Downloading And Installing The Latest Version Of The Firmware

    Installing the System Troubleshooting 1. Check the monitor controls. Adjust contrast and brightness as required. 2. Inspect all power and interconnecting cables. Check that all console connectors are fully engaged. 3. Check that all iLO MP board connectors are fully engaged. 4.
  • Page 89: Troubleshooting Using Leds

    Installing the System Troubleshooting Troubleshooting Using LEDs If you suspect a hardware failure during installation, the power and system LEDs, located on the front control panel, will help you identify the problem. The following sections describe their functions. You may want to back up your data or replace a component before it fails.
  • Page 90 Installing the System Troubleshooting Table 1-15 Control Panel LEDs and Switches (Continued) Name Function Power Button Controls the power supply (turns system power on or off) if power is available to the power supply. (Controls both power supplies if two are installed). If power is off but power is available to the power supplies, pressing the power button does the following: •...
  • Page 91: Table 1-16. System Led States

    Installing the System Troubleshooting Power and System LEDs The power and system LEDs indicate the state of the system. When the system LED is blinking yellow or red, a problem exists. Table 1-16 provides system LED states. Table 1-16 System LED States System LED State ac power is off if power LED is off.
  • Page 92: Table 1-17. 10/100/1000 Base-T Ethernet Lan Connector Leds

    Installing the System Troubleshooting Table 1-17 lists the 10/100/1000 Base-T ethernet LAN connector LEDs. Table 1-17 10/100/1000 Base-T Ethernet LAN Connector LEDs Description 1000BT Blinking green: the 1000 MHz with ethernet protocol and twisted-pair wiring is enabled; off; no link. 100BT Blinking green: the 100 MHz with ethernet protocol and twisted-pair wiring is enabled;...
  • Page 93: Information To Collect Before You Contact Support

    Installing the System Troubleshooting Information to Collect Before You Contact Support Before you contact HP support, you should: Step 1. Check information on troubleshooting and attempt to solve the problem. • Note failure symptoms and error indications (LEDs and messages) by checking the system event log.
  • Page 94 Installing the System Troubleshooting Chapter 1...
  • Page 95: Index

    Index front bezel rack configuration airflow guides, remove and replace front panel ARP Ping LEDs and switches bezel Hot-Plug Disk Drives pedestal-mount, remove and replace LEDs rack-mount, remove and replace hot-pluggable disk drives booting installation HP-UX single-user mode LVM maintenance mode core iLO Manageability Card CM command...
  • Page 96 Index installing assigning with LC command pedestal system memory convert from rack mount installing mount power button toe-tag full state troubleshooting full state, defined console off state off state, defined hard drive PR command intermittent server problems problems methodology reset command See PR operating system standby state using power button...

This manual is also suitable for:

Rp3410Rp34409000 rp34109000 rp3440

Table of Contents