Install Additional Mass Storage Devices

NOTE
If you are installing an IDE drive or internal
SCSI devices with certain configurations, you
may need additional cables or adapters. For
part numbers for HP cables, adapters, and
trays, and configuration information, see the
Technical Reference Label on the side of the
chassis or the Management Software CD-ROM.
Preinstalled Devices
A flexible disk drive is preinstalled in Shelf 1
An IDE CD-ROM drive is preinstalled in Shelf 2
A SCSI hard disk drive is preinstalled in Shelf 5 in the
NetServer Model 2100 (SCSI ID=0)
Boot device priority order
The system searches for a bootable device in the following order:
1. Flexible disk drive with bootable flexible disk
2. IDE CD-ROM drive with bootable CD-ROM
3. IDE hard disk drive (if user installs)
4. PCI Slots in the following order: 3, 1, 2, 4
Technical
Reference
Front
Label
All front shelf hard disk drives
must be installed in the mass
storage trays provided
Shelf 1
(3.5" flexible
disk drive)
Shelf 2
(CD-ROM drive)
Shelf 3
Shelf 4
(mass storage
tray installed)
SCSI Termination
The NetServer SCSI cable is terminated. Verify added devices
are not actively terminated.
SCSI Addressing
Each SCSI device must have a different SCSI address or ID.
This address (0 through 6) dictates where each SCSI device is
in the boot priority order and is set by means of jumpers located
on the outside of the device.
The figure and table to the right are an example of a SCSI hard
disk drive that may be preinstalled in your HP NetServer Model
2100. Use this as a general reference for jumper locations and
settings. Refer to the documentation that came with your SCSI
device for the correct jumper locations and settings. Refer to the
Technical Reference Label on the side of the NetServer chassis
for recommended SCSI setting strategy.
8

Configure the HP NetServer

1. Replace the air cooling duct and cover. Refer to the diagram in
Roadmap Step 4 showing proper alignment of the cover.
Connect all external power and data cords.
2. Turn on the HP NetServer and monitor and insert the HP
NetServer Navigator CD-ROM into the CD-ROM drive. If the
NetServer doesn't boot from the Navigator CD-ROM, turn the
power off, wait 10 seconds, and turn the power on again. If the
system fails to boot, follow the instructions on the screen:
Press F2 to enter Setup
Press F4 to accept automatic configuration update
3. Go to the HP NetServer Navigator Main Menu and click on the
"Configuration Assistant" icon.
4. Click the "Express" button to begin the configuration process .
5. Select your NOS. If you choose Novell NetWare 4.1 or Windows
NTAS 3.51, you will be prompted to choose between automatic
or manual NOS install.
Installing a SCSI Tape Drive
1. Set the jumpers on the device to an unused address. Refer to the SCSI
Addressing section below for more information. Verify terminator power is off.
2. Remove the tray from one of the front shelves and store it.
3. Install the tape drive, using the rails supplied with the device.
4. Connect the tape drive to SCSI cable and power cable.
5. Remove the shelf cover plate from inside the front bezel before replacing the
cover. See figure below.
Installing Additional SCSI Hard Disk Drives
1. Set the jumpers on the device to an unused address. Refer to the Technical
Reference Label on the side of the NetServer chassis and the SCSI
Addressing section below for more information.
2. Install the drive.
Rear Shelf 6
four 1/4" screws supplied with the device. Replace the shelf cover plate when
the device is in place.
Front Shelves:
3. Connect the hard disk drive to SCSI cable and power cable.
Installing an Additional IDE Device
If you are installing an additional IDE device,such as an IDE CD-ROM drive or
IDE hard disk drive, refer to the
User Guide.
You may need to remove the filler panel from inside the front bezel before
replacing the cover. See figure below.
Front Cover
Filler panel
Example of a hard disk drive and jumper settings.
A0, A1 and A2 are SCSI ID settings and TE is device
active termination setting (always off).
6. Choose automatic mode for first-time installation of NetWare 4.1 or
7. If you are installing non-Plug-and-Play ISA boards, Configuration
8. Install your NOS. If you selected HP automated installation process,
9. Install Server Management Software.
: Remove the rear shelf cover plate and install the drive using the
Use the mass storage trays supplied with your NetServer.
Accessories
Back
4x
JUMPERS
NTAS 3.51 on a factory-configured HP NetServer E 30.
Choose manual mode to install an alternative NOS, to customize
your hard drive partition or if you replaced HP components (for
example, replaced an HP board with a third-party NIC or SCSI
controller board.
Assistant will instruct you when to install them. During installation, the
HP NetServer may reboot several times. If the system fails to boot,
follow the instructions on the screen to correct the problem.
you will be guided through the process by a series of HP screens.
If you selected NOS vendor installation process, view and print the
HP NOS installation tips. Install the NOS using the installation utility
supplied with your NOS.
chapter in your HP NetServer
Shelf 5
(SCSI hard
disk drive)
Shelf 6
0
1
2
SCSI ID
3
4
5
6
reserved
7