Power supply upgrade kit
Hide thumbs Also See for D7171A - NetServer - LPr:
Table of Contents

Advertisement

Chapter 2
3. Grasp the cage front panel and remove it from the cabinet
(see Figure 2-2). Set it aside.
Figure 2-2. Removing the Cage Front Panel
4. Remove the power supply module from the cage, then set the new cage
in the open bay.
5. Push in the cage most of the way. Align and guide the cage i nto the
chassis slowly.
6. There are three connectors to attach to install the power supply cage:
two large, white connectors that snap in place on the underside of the
circuit board, and one small, black connector that routes through the
rectangular slot in the circuit board and plugs into its top side.
First, attach the two large, white connectors. Attach the inner white
connector (farthest from you) first, then attach the outer white
connector. Make sure both connectors "click" into place and that the
plastic locks are secure.
Cage and Power Supply Installation
Front Panel
Torx
Screws
11