QLIS_LoginPduContinue:
41272
CONN_STATE_IN_LOGIN, Un-
known InitTaskTag
QLIS_LoginPduContinue:
41283
TSIH 0x%x out of range
QLIS_LoginPduContinue:
41284
Session does not exist,
invalid TSIH 0x%x
QLIS_LoginPduContinue:
41353
Session does not exist,
invalid TSIH 0x%x
QLIS_LoginPduContinue:
41354
Unexpected CHAP key detec-
ted
QLBI_SetPortInfo:
QLUT_AllocatePortalObject
41508
failed (PortType 0x%x,
PortId 0x%x)
QLBI_GetLunInfo: INQUIRY
41626
failed, TPB status 0x%x
QLBI_GetLunInfo: INQUIRY
41629
failed, TPB status 0x%x
QLBI_Passthru: Invalid
41635
data length %d bytes
QLBI_GetLunInfo: INQUIRY
41636
failed, TPB status 0x%x
QLBI_GetLunInfo: INQUIRY
41696
failed, TPB status 0x%x
QLBI_Passthru: Invalid
41700
CDB length %d bytes
iSCSI login PDU received with an incorrect
initiator task tag for a session which is partially
logged in. This would occur if a login PDU
App
Error
other than the initial login PDU used an initiator
task tag which was different than the initiator
task tag provided in the initial login PDU.
iSCSI login PDU was received with a target
session identifying handle (TSIH) out of range.
This would occur if the iSCSI initiator attempt-
App
Error
ing the login failed to used the TSIH value
provided in the Target Login Response PDU
(router is target) in subsequent login PDUs.
iSCSI login PDU was received with an invalid
TSIH value. The TSIH is invalid because there
is no session with that TSIH value. This would
App
Error
occur if the iSCSI initiator attempting the login
failed to used the TSIH value provided in the
target login response PDU (router is target) in
subsequent login PDUs.
iSCSI login rejected due to a CHAP authentic-
App
Error
ation error.
App
Error
iSCSI login rejected due to a CHAP key error.
Failed to allocate an object for Set Port Info
IOCTL processing: PortType: 0 = FC, 1 = iSC-
App
Error
SIPortId: 0 = FC1 or iSCSI1(GE1), 1 = FC2 or
iSCSI2 (GE2)
Inquiry command failed. The Inquiry command
App
Error
was issued by the router as part of its discovery
process.
Pass-Through command for Inquiry command
for page 83 failed. The Inquiry command was
App
Error
issued by the router as part of its discovery
process.
Pass-Through command for Read Capacity
command failed. The Read Capacity command
App
Error
was issued by the router as part of its discovery
process.
Read Capacity command failed. The Read
App
Error
Capacity command was issued by the router
as part of its discovery process.
Pass-Through command issued by management
App
Error
application (such as GUI) was aborted.
Pass-Through command issued by management
App
Error
application (such as GUI) failed due to invalid
command descriptor block (CDB) length.