  • Page 1 53-1002265-01 18 March 2011 Dell PowerConnect B- Series TI24X Hardware Installation Guide...
  • Page 2 Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo,, Dell OpenManage and PowerConnect are trademarks of Dell Inc.; Microsoft, Windows, Windows Server, MS-DOS and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
  • Page 3: Table Of Contents

    Contacting Dell ........
  • Page 4 In this chapter ......... . . 37 Hardware maintenance schedule ......37 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 5 China RoHS ......... 64 Dell PowerConnect B-Series TI24X Hardware Installation Guide...
  • Page 6 Danger ..........68 Dell PowerConnect B-Series TI24X Hardware Installation Guide...
  • Page 7: About This Document

    Contacting Dell ........
  • Page 8: Text Formatting

    The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information. viii Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 9: Related Publications

    Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues:...
  • Page 10 2. Click your country or region at the bottom of the page. For a full listing of countries and regions, click All. 3. In the Support menu, click All Support. 4. Choose the method of contacting Dell that is convenient for you. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 11: Product Overview

    PowerConnect B-Series TI24X Configuration Guide. Hardware features This section describes the physical characteristics of the PowerConnect B-Series TI24X models. For details about physical dimensions, power supply specifications, and pin-outs, refer to Appendix A, “Hardware Specifications”. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 12: Control Features

    PC, straight-through EIA or TIA DB-9 serial cable (M/F) is included. The console port is located in the upper right of the front panel. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 13: Network Interfaces

    Vendor: Brocade Version: 1 Part# : PLRXPLSCS4371 Serial#: C847UQ04H Port 8: Type : EMPTY Port 9: Type : EMPTY Port 10: Type : EMPTY Port 11: Type : EMPTY Port 12: Type : EMPTY Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 14 The ports 25~28 are 10/100/1000 copper ports that use auto-sensing and auto-negotiating to determine the speed (10 Mbps, 100 Mbps, or 1000 Mbps) and mode (full-duplex or half-duplex) of the port at the other end of the link, and adjust port speed accordingly. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 15: Leds For Network Interfaces And Power Supplies

    This is the right LED on RJ45 On or Blinking Traffic is being transmitted or received on the copper port. No traffic is being transmitted or received on the copper port. System Power and Power Supply LEDs Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 16: Power Supplies

    You can remove one of the supplies without interrupting operation because the remaining power supply provides enough power for all of the ports. For power supply hardware specifications, refer to “Power supply specifications” on page 55. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 17 Failure to do this can result in damage to the power supply or the device, or both (the device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source). Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 18 Hardware features Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 19: In This Chapter

    Chapter 3, “Connecting Network Devices and Checking Connectivity”. Dell PowerConnect systems ship with all of the items listed below. Please review the list and verify the contents. If any items are missing, please contact the place of purchase. Package contents Verify the package contents listed below: •...
  • Page 20: General Requirements

    Ensure that the physical environment where the device will be “Preparing the installation site” installed has the proper cabling and ventilation. on page 15 Install the Dell PowerConnect device on a desktop or in an “Installing the device” equipment rack. Devices may also be wall-mounted. page 15 When the device is installed, plug the PDU power cords (C13-C14) “Powering on the system”...
  • Page 21: Installation Precautions

    Installation precautions Installation precautions Follow these precautions when installing a Dell PowerConnect device. General precautions CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 40°C (104°F). CAUTION Make sure that air flow around the front, sides, and back of the device is not restricted.
  • Page 22: Lifting Precautions

    DANGER Do not use the handles on the power supply units to lift or carry a Dell PowerConnect device. DANGER Mount the devices you install in a rack or cabinet as low as possible. Place the heaviest device at the bottom and progressively place lighter devices above.
  • Page 23 The PowerConnect B-Series TI24X power supply is designed exclusively for use with PowerConnect B-Series TI24X devices. Installing the power supply in a device other than the PowerConnect B-Series TI24X will cause extensive damage to your equipment. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 24 DANGER Power supplies are hot swappable. However, Dell recommends that you disconnect the power supply from AC power before installing or removing the supply. The device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source.
  • Page 25: Preparing The Installation Site

    “Powering on the system” on page 18. Rack mount installation For rack mount installation,the Dell PowerConnect B-Series TI24X supports the use of a two post Telco equipment rack and four post equipment rack. NOTE For additional support under the stack of switches. Use Dell 1U shelf, Dell p/n:G118R.
  • Page 26 Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 27 PowerConnect B-Series TI24X and would invalidate your warranty. Figure 5 shows how to attach the short mounting brackets. FIGURE 5 Attaching the short mounting brackets Mount the device in the rack as illustrated in Figure Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 28: Powering On The System

    Attach the AC PDU power cords (C13-C14) to the AC connector on the rear panel as shown in Figure NOTE Align the locating notch on the underside of the AC PDU power cords (C13-C14) before inserting. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 29: Powering Off The System

    If the links on these cables are good and the connected device is powered on, the link LEDs will light. Table 4 provides more details on specific LED conditions after system start-up. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 30: Observing The Power Status Leds

    You need to run a terminal emulation program on the PC. 2. Open the terminal emulation program and set the session parameters as follows: • Baud: 9600 bps • Data bits: 8 • Parity: None • Stop bits: 1 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 31 Most PC serial ports also require a cable with a female DB-9 connector. Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female. Serial cable options between a Dell switch or router and a PC or terminal are shown in Figure...
  • Page 32 As indicated in Figure 8 Figure 9, some of the wires should not be connected. If you do connect the wires that are labeled "Reserved", you might get unexpected results with some terminals. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 33: Connecting Network Devices And Checking Connectivity

    The procedures in this manual are intended for qualified service personnel. This chapter provides the details for connecting network devices and checking network connectivity. By default, the CLI is not protected by passwords. To secure CLI access, Dell strongly recommends assigning passwords. NOTE You can assign passwords using Brocade Network Advisor if an enable password for a Super User has been configured on the device.
  • Page 34: Recovering From A Lost Password

    4. Enter no password at the prompt. (You cannot abbreviate this command.) 5. Enter boot system flash primary at the prompt. This command causes the device to bypass the system password check. 6. After the console prompt reappears, assign a new password. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 35: Configuring Ip Addresses

    You must configure at least one IP address using the serial connection to the CLI before you can manage the system using the other management interfaces. In addition, Dell routers require an IP subnet address for the subnet in which you plan to place them in your network.
  • Page 36: Connecting Network Devices

    “10/100/1000 Gigabit port pinouts” on page 53. Connecting to Ethernet or fast Ethernet hubs For copper connections to Ethernet hubs, a 10/100Base-TX or 1000Base-T switch, or another Dell PowerConnect device, a crossover cable is required (Figure 10 Figure 11). If the hub is equipped with an uplink port, it will require a straight-through cable instead of a crossover cable.
  • Page 37: Connecting To Workstations, Servers, Or Routers

    Automatic MDI or MDIX detection All 10/100/1000 Copper ports on the Dell PowerConnect B-Series TI24X devices support automatic Media Dependent Interface (MDI) and Media Dependent Interface Crossover (MDIX) detection. This feature is enabled on all Gigabit copper ports by default. For each port, you can disable auto MDI or MDIX, designate the port as an MDI port, or designate the port as an MDIX port.
  • Page 38: Connecting A Network Device To A Fiber Port

    You must install a fiber optic module (SFP or SFP+ transceiver) in each Gigabit Ethernet and 10-Gigabit Ethernet fiber port you want to use. You can install a new fiber optic module in a port while the Dell PowerConnect device is powered on and running.
  • Page 39: Testing Connectivity

    <num>] [size <byte>] [quiet] [numeric] [no-fragment] [verify] [data <1-to-4 byte hex>] [brief] NOTE If you address the ping to the IP broadcast address, the device lists the first four responses to the ping. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 40: Observing Leds

    You can use the CLI. If you have configured an IP address on the device, you also can use Brocade Network Advisor. If a problem persists after taking these actions, contact Dell technical support. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 41: Tracing A Route

    Troubleshooting network connections Tracing a route To determine the path through which a Dell PowerConnect device can reach another device, enter a command such as the following at any level of the CLI on the PowerConnect device. PowerConnect> traceroute 192.33.4.7 Syntax: traceroute <host-ip-addr>...
  • Page 42 Troubleshooting network connections Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 43: Managing The Powerconnect B-Series Ti24X

    Power supply 1 (NA - NA - Regular) present, status ok Power supply 2 not present Fan 1 ok, speed (auto): [[1]]<->2<->3 Fan 2 ok, speed (auto): [[1]]<->2<->3 Fan 3 ok, speed (auto): [[1]]<->2<->3 Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 44: Displaying Temperature Messages

    The software reads the temperature sensor and polls other hardware sensors according to the value set for the device poll time, which is 60 seconds by default. You can change the device poll time using the CLI. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 45: Removing Mac Address Entries

    Syntax: chassis poll-time <value> NOTE The <value> can be 0 - 65535 seconds. Removing MAC address entries You can remove learned MAC address entries from the Dell system MAC address table. You can remove the following entries: • All MAC address entries •...
  • Page 46 Removing MAC address entries Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 47: Maintaining The Powerconnect B-Series Ti24X Hardware

    DANGER The procedures in this manual are for qualified service personnel. The PowerConnect B-Series TI24X switch hardware components require minimal maintenance. Dell recommends that you clean the fiber- optic connectors on fiber-optic ports and the connected fiber cable each time you disconnect the cable.
  • Page 48: Removing A Fiber Optic Module

    5. Grasp the latch and pull the fiber optic module out of the port. FIGURE 13 Removing a fiber optic module 6. Store the fiber optic module in a safe, static-free place or in an anti-static bag. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 49: Installing A New Fiber Optic Module

    1. Remove the protective covering from the fiber-optic port connectors and store the covering for future use. 2. Before cabling a fiber optic module, Dell strongly recommends that the cable connectors and the port connectors are cleaned thoroughly. 3. Gently insert the cable connector or connectors (a tab on each connector should face upward) into the port connector or connectors until the tabs lock into place.
  • Page 50: Installation Precautions And Warnings

    Replacing a power supply DANGER Power supplies are hot swappable. However, Dell recommends that you disconnect the power supply from AC power before installing or removing the supply. The device can be running while a power supply is being installed or removed, but the power supply itself should not be connected to a power source.
  • Page 51: Ac Power Supplies

    Removing an AC power supply Follow the steps to remove an AC power supply. 1. Unplug the PDU power cords (C13-C14) from the power source. 2. Disconnect the PDU power cords (C13-C14) from the power supply. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 52 5. Continue to pull the power supply until it is removed from the device. FIGURE 16 Removing the power supply 6. Place the power supply in an anti-static bag for storage. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 53 With the other hand, support the underside of the power supply, and insert the power supply into the empty power supply slot. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 54 The power supply is right-side up when the power connector is on the left and the fan vent is on the right. FIGURE 19 Installing the power supply Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 55: Replacing The Fan Tray

    But, you need to replace the fan tray quickly after removing it from the device, otherwise the device will overheat. The fan tray is located in a slot at the rear of the PowerConnect B-Series TI24X . This section provides information about the following topics: Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 56: Installation Precautions And Warnings

    1. Disconnect the PDU power cords (C13-C14) from the power supply. NOTE If the device is connected with two Power supplies, you need to disconnect both the PDU power cords (C13-C14) from the device. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 57 5. Connect the PDU power cords (C13-C14) to the power supply (refer to “Powering on the system” on page 18). 6. Verify that the system is working properly as instructed in “Verifying proper operation” page 19. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 58 Replacing the fan tray Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 59: Hardware Specifications

    Power supply specifications • “Overview” • “Key features” • “Physical dimensions and weight” • “Environmental considerations” • “Power supply consumption” • “Input connector and plug” • “Regulatory compliance” • “Safety warnings” • “Electrical specifications” Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 60: Device Specifications

    • (6.01 kg) 13.22 lbs single power supply Environmental considerations For optimal performance, operate or store your Dell PowerConnect B-Series TI24X device in compliance with the following environmental conditions. Operating environment TABLE 7 Operating environmental conditions for the device Description...
  • Page 61: Regulatory Compliance

    EN 60950-1, 2nd Edition CAN/CSA C22.2 No.60590-1-07, 2nd Edition EN 60825-1, Safety of Laser Products - Part 1 EN 60825-2, Safety of Laser Products - Part 2 IEC 60950-1, 2nd Edition UL 60950-1, 2nd Edition Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 62: Power Source Interruptions

    Most PC serial ports also require a cable with a female DB-9 connector. Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female. Serial cable options between the PowerConnect B-Series TI24X and a PC or terminal are shown in Figure Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 63: Cable Specifications

    Pin Number MDI-X ports Pin Number Not used Not used Not used Not used Cable specifications Table 12 lists the cable specifications for the cables used with the Gigabit, and 10-Gigabit Ethernet ports. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 64 2 - 26 XFP module 62.5/125 2 - 33 50/125 2 - 66 50/125 2 - 82 50/125 2000 2 - 300 NOTE SMF = Single Mode Fiber, MMF = Multi-Mode Fiber. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 65: Pdu Power Cords(C13-C14)

    All power supplies are auto-sensing and auto-switching. Key features Refer to “Power supplies” on page 6 for the key features of the PowerConnect B-Series TI24X power supplies. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 66: Physical Dimensions And Weight

    Storage environment TABLE 15 Storage environmental conditions for power supplies Description Range Storage temperature -40° to 85°C (-40° to 185°F) Storage humidity 95% maximum, non-condensing Storage altitude 4545.45 meter (15,000 feet) maximum Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 67: Power Supply Consumption

    C14 type: UL/cUL 15A/250V, VDE 10A/250V Orientation: Ground pin up. Figure 29 shows the power plug and connector for AC power supplies. FIGURE 29 AC PDU power cords (C13-C14) plug and input connector Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 68: Regulatory Compliance

    Partes adentro no reparables por el operador. Refiera reparo a personal autorizado. ATTENTION Entretien et répartions internes ne sont autorisés qu'au personnel technique qualifié. GEFAHR Zugang zur Bedienung nicht erförderlich. Wartung nur durch qualifiziertes Personal. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 69: Electrical Specifications

    The PowerConnect B-Series TI24X power supply is designed exclusively for use with PowerConnect B-Series TI24X devices. Installing the power supply in a device other than the PowerConnect B-Series TI24X will cause extensive damage to your equipment. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 70 Power supply specifications Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 71: Regulatory Approval And Statements

    EN 61000-4-4 Electrical fast transient • EN 61000-4-5 Surge • EN 61000-4-6 Conducted disturbances induced by radio-frequency fields • EN 61000-4-8 Power frequency magnetic field • EN 61000-4-11 Voltage dips and sags Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 72: Regulatory Statements

    This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 73: Japan Power Cords

    Class A device (Broadcasting Communication Device for Office Use): This device obtained EMC registration for office use (Class A), and may be used in places other than home. Sellers and/or users need to take note of this. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 74: China Rohs

    Regulatory statements China RoHS Restriction on the use of certain hazardous substances in electrical and electronic equipment. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 75 De no hacerse así, el suministro de corriente o el instrumento podrían resultar dañados. (El instrumento puede estar encendido mientras se instala o retira un suministro de corriente, pero el suministro de corriente en sí no deberá conectado a la corriente). Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 76 Compare esta suma con el límite nominal para el circuito. Las capacidades nominales de corriente máximas están generalmente impresas en los instrumentos, cerca de los conectores de corriente de entrada. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 77 Assurez-vous que le bloc d’alimentation est correctement inséré dans l’emplacement. N’insérez jamais le bloc d’alimentation à l’envers. PRECAUCIÓN Verifique que el suministro de energía esté bien insertado en la ranura. No inserte nunca el suministro de energía en posición invertida. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 78 Alle Glasfaser-Schnittstellen verwenden Laser der Klasse 1. DANGER Toutes les interfaces en fibres optiques utilisent des lasers de classe 1. PELIGRO Todas las interfaces de fibra óptica utilizan láser de clase 1. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 79 PELIGRO Verifique que circuitos de la fuente de corriente están conectados a tierra correctamente; luego use el cordón de potencia suministrado con el instrumento para conectarlo a la fuente de corriente. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 80 DANGER Power supplies are hot swappable, which means they can be removed and replaced while the chassis is powered on and running. However, Dell recommends that you disconnect the power supply from the wall outlet before removing and replacing the supply.
  • Page 81 Il est possible que le ventilateur tourne encore à grande vitesse. PELIGRO Procure no insertar los dedos accidentalmente en la bandeja del ventilador cuando esté desmontando el chasis. El ventilador podría estar girando a gran velocidad. Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...
  • Page 82 Danger Dell PowerConnect B-Series TI24X Hardware Installation Guide 53-1002265-01...