Power supply

A correctly installed, earthed socket is required for the electrical sup-
ply. The supply must have a fuse rating of at least 10 Amps. If the
socket is not accessible once the appliance is built in, the electrical
installation must include suitable means of isolating the appliance
from the mains (e.g. a fused spur).
Before initial start-up, refer to the appliance rating plate to ascertain
if supply voltage and current values correspond with those of the
mains at the installation location.
e.g.: AC 220 ... 240 V 50 Hz or
(i.e. 220 to 240 volts alternating current, 50 Hertz)
The rating plate is inside the appliance on the left.
The mains cable may only be changed by a qualified electrician or
competent person. If your appliance needs repairing, please contact
your local AEG Service Force Centre.

Electrical Connection

Any electrical work required to install this appliance should be carried
out by a qualified electrician or competent person.
WARNING – THIS APPLIANCE MUST BE EARTHED
The manufacturer declines any liability should these safety mea-
sures not be observed.
Before switching on, make sure the electricity supply voltage is the
same as that indicated on the appliance rating plate. The rating plate
is inside, on the left.
The appliance is supplied with a 13 amp plug fitted. In the event of
having to change the fuse in the plug supplied, a 13 amp ASTA
approved (BS 1362) fuse must be used.
Important
The wires in the mains lead are coloured in
accordance with the
following code:
Green and Yellow Earth
Blue
Brown
16
220 ... 240 V ~50 Hz
Neutral
Live
GREEN & YELLOW
13 AMP. FUSE
BROWN
BLUE
CORD CLAMP
207