Mitsubishi Electric MSZ-FD25VA Service Manual page 29

Split-type, heat pump air conditioners indoor unit wireless type
Hide thumbs Also See for MSZ-FD25VA:
Table of Contents

Advertisement

Indoor unit operates by pressing EMERGENCY OPERATION switch, but does not operate with the remote controller.
Check of remote controller and indoor electronic control P.C. board
B
wCheck if the remote controller is exclusive for this air conditioner.
Press OPERATE/STOP(ON/OFF) button on the remote controller.
Is LCD display on the remote con-
troller visible?
Yes
Remove the batteries, then set them back
and press RESET button. (Refer to 10-
1.4.) Check if the unit operates with the
remote controller.
Does the unit operate with the
remote controller?
Yes
OK
No
Replace the batteries. (Refer to 10-1.4.)
(not clear)
No
Turn ON a radio to AM and press
OPERATE/STOP(ON/OFF) button on the remote controller.
Is noise heard from radio?
Are there any fluorescent lights of
inverter or rapid-start type within
the range of 1 m?
Replace the indoor electronic
control P.C. board.
(including the receiver)
No
Yes
Yes
No
29
Replace the remote controller.
Reinstall the unit away from lights.
Attach a filter on receiving part.