EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-WM4500
PLC-WM4500L
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-WM4500/L - 4500 Lumens

  • Page 1 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-WM4500 PLC-WM4500L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Contents Overview ........................8 Serial Interface Specification ..................8 Transfer Specification ....................8 Connection ......................8 Notes for communication ..................9 Notation Convention ....................9 Functional Execution Command Table ..............10 Image Command Table..................10 PC Adjust Control Command Table ..............10 Input Control Command Table ................10 Screen Control Command Table .................10 Lamp Command Table..................11 Sound Command Table..................11...
  • Page 3 PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.4.9 CF_OFFSET- Command ..................20 8.4.10 CF_NZRED Command ..................20 8.4.11 CF_PROGV Command..................21 8.4.12 CF_IMAGE Command...................21 8.4.13 CF_IMAGEADJ Command ...................22 PC Adjust Control Command ................23 8.5.1 CF_FSYNC Command ..................23 8.5.2 CF_TDOTS Command ..................23 8.5.3 CF_CLPPHASE Command ...................23 8.5.4 CF_H-POS Command ...................24 8.5.5...
  • Page 4 PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.9.3 CF_BLTINSP Command ..................35 8.10 Setting Command ....................36 8.10.1 CF_LANG Command ....................36 8.10.2 CF_MENUPOSITION Command................36 8.10.3 CF_INPUTBUTTON Command................36 8.10.4 CF_DISP Command ....................37 8.10.5 CF_BACKGND Command ..................37 8.10.6 CF_LOGO Command ....................38 8.10.7 CF_PIP Command ....................38 8.10.8 CF_PIPMODE Command ..................38 8.10.9...
  • Page 5 PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.39 CF_FDEFAULT Command ..................47 8.11 Other Commands....................48 8.11.1 CF_KEYEMU Command ..................48 8.11.2 CF_MENU Command ....................48 8.11.3 CF_POWER Command ..................49 8.11.4 CF_FREEZE Command ..................49 8.11.5 CF_VMUTE Command ..................49 Status Read Command ....................50 Format ........................50 Transfer Example ....................50 Operation Condition .....................50 Image Status Read Command ................51 9.4.1...
  • Page 6 PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Input Read Command...................58 9.7.1 CR_INPUT Command ...................58 9.7.2 CR_SOURCE Command..................58 9.7.3 CR_SRCINP1 Command..................58 9.7.4 CR_SRCINP2 Command..................58 9.7.5 CR_SRCINP3 Command..................59 9.7.6 CR_SYSTEM Command ..................59 9.7.7 CR_SYSLIST Command ..................60 9.7.8 CR_MODELIST Command ...................60 Screen Status Read Command................61 9.8.1 CR_SCREEN Command ..................61 9.8.2...
  • Page 7 PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.8 CR_PIPMODE Command..................67 9.11.9 CR_PIPMAININP Command .................68 9.11.10 CR_PIPSUBINPU Command ................68 9.11.11 CR_PIPSIZE Command ..................68 9.11.12 CR_PIPFRAMELOCK Command .................69 9.11.13 CR_PIPSTORE Command ..................69 9.11.14 CR_HDMI SETUP Command ................69 9.11.15 CR_HDMI SOUND Command................69 9.11.16 CR_FILH Command ....................69 9.11.17 CR_FILTIMER Command..................70 9.11.18 CR_FILREPL Command ..................70 9.11.19 CR_FANSPEED Command...................70...
  • Page 8: Overview

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Overview 0û This Functional Specification defines communication for PLC-WM4500 / WM4500L. 0û Supporting Firmware Ver. 1.x of the projector. 0û Most commands are used to control a projector remotely from a computer with RS-232C. Therefore commands in this document are defined as Expand Serial Commands.
  • Page 9: Notes For Communication

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Notes for communication Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). There are two types of commands; Functional Execution Commands and Status Read Command.
  • Page 10: Functional Execution Command Table

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Functional Execution Command Table 5.1 Image Command Table Item Execute command CF_BRIGHT_%1 [CR] Set value of Brightness CF_CONT_%1 [CR] Set value of Contrast CF_COLOR_%1 [CR] Set value of Color CF_TINT_%1 [CR] Set value of Tint CF_SHARP_%1 [CR] Set value of Sharpness CF_GAMMA_%1 [CR]...
  • Page 11: Lamp Command Table

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications CF_KYSTNMODE _%1 [CR] Set Keystone store mode CF_CEIL_%1 [CR] Set ON/OFF of Ceiling CF_REAR_%1 [CR] Set ON/OFF of Rear CF_SCREENASPECT_%1 [CR] Set Screen aspect function Lamp Command Table Execute command Item CF_LAMPMODE_%1 [CR] Select Lamp mode CF_LAMPLIFECONTRL_%1 [CR] Select Lamp life mode Sound Command Table...
  • Page 12: Other Command Table

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications CF_CCAPTIONCOLOR_%1 Set color of Closed caption [CR] CF_DELAYCTRL_%1[CR] Set Video delay control function CF_TESTPAT_%1[CR] Set Test pattern display function CF_FDEFAULT_%1 [CR] Reset to Factory Default settings Other Command Table Execute command Item CF_KEYEMU_%1 [CR] The same operation as Control Key CF_MENU_%1 [CR] Set ON/OFF of Menu...
  • Page 13: Status Read Command Table

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Status Read Command Table Image Status Read Command Table Status Read command Item CR_BRIGHT [CR] Get value of Brightness CR_CONT [CR] Get value of Contrast CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint CR_SHARP [CR] Get value of Sharpness CR_GAMMA [CR]...
  • Page 14: Screen Status Read Command Table

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Screen Status Read Command Table Status Read command Item CR_SCREEN [CR] Get selected screen size CR_VSCALE[CR] Get setting status of V Scale CR_VPOS[CR] Get setting status of V Position CR_HSCALE[CR] Get setting status of H Scale CR_HPOS[CR] Get setting status of H Position CR_KYSTNMODE[CR]...
  • Page 15: Other Status Read Command Table

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Get selected location of infrared remote receiver of remote CR_RSENS [CR] control CR_RTYPE [CR] Get supported Remote Control type (IR/RF) CR_P-MANE [CR] Get Power management setting status CR_P-MANETIME [CR] Get setting time for Power Management CR_STANDBYMODE [CR] Get selected mode of Standby function CR_ON-STA [CR]...
  • Page 16: Error Code Table

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Error Code Table Error Code Contents -When the received data cannot be decoded -Parameter designation error (wrong digit number, including invalid value, etc.) Normal reception (This is “Not” error) The function is not available in the selected Mode Selected value is out of range (Not reflected) Command mismatched to Hardware (the command is for Optional function which is not implemented)
  • Page 17: Functional Execution Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Functional Execution Command 8.1 Format 1) PC issues commands in format as below: Pattern1: “CF_ COMMAND” [CR] Pattern2: “CF_ COMMAND _” %1 [CR] CF_: Header COMMAND: String %1: Parameter (String) _: Space (To separate COMMAND and Parameter) 2) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
  • Page 18: Image Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Image Command 8.4.1 CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “000-063”--------------- Directly specify setting value of Brightness “UP”--------------------- Increment setting value of Brightness by 1 “DN”--------------------- Decrement setting value of Brightness by 1 Set user controlled value of Brightness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
  • Page 19: Cf_Sharp Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command “CF_SHARP_%1” [CR] “000-031”--------------- Directly specify setting value of Sharpness “UP”--------------------- Increment setting value of Sharpness by 1 “DN”--------------------- Decrement setting value of Sharpness by 1 Set user controlled value of Sharpness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
  • Page 20: Cf_Coltemp Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1” [CR] “000” ------------------------------ Xlow “001”------------------------------- Low “002”------------------------------- Mid “003”------------------------------- High Set Color Temperature The value set by this command will not be stored in the projector’s memory. Details Therefore, when the power is turned to ALL OFF status, the value returns to the original setting.
  • Page 21: Cf_Progv Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.4.11 CF_PROGV Command Command “CF_PROGV_%1” [CR] “ON” ----------------- Set Progressive scan to On. “FILM” --------------- Set Progressive scan to Film. “OFF” ---------------- Set Progressive scan to OFF. “UP” ------------------ Switch setting forward direction (OFF→ON→FILM→OFF) “DN”...
  • Page 22: Cf_Imageadj Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.4.13 CF_IMAGEADJ Command Command “CF_IMAGEADJ_%1”[CR] “RST”------ Reset adjusted value for the Image “STR1”---- Store current adjusted value to Image 1 “STR2”---- Store current adjusted value to Image 2 “STR3”---- Store current adjusted value to Image 3 “STR4”---- Store current adjusted value to Image 4 “STR5”---- Store current adjusted value to Image 5 “STR6”---- Store current adjusted value to Image 6...
  • Page 23: Pc Adjust Control Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1 Set value of Fine Sync in PC signal (Available only in the normal Power ON status) Details...
  • Page 24: Cf_H-Pos Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.5.4 CF_H-POS Command Command “CF_H-POS_%1” [CR] “0000-nnnn” -------- Directly specify setting value of Horizontal Position “nnnn” indicates maximum value, which is current value of (Total dots - Display area H) “UP” ------------------- Increment setting value of Horizontal Position by 1 “DN”...
  • Page 25: Cf_Dline Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100-nnnn” ----------- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of (Total Line - Position V). “UP” ------------------- Increment setting value of Display Line by 1 “DN”...
  • Page 26: Input Control Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command “CF_INPUT_%1” [CR] “1”------------------------- Select Input 1 (not switching Source) “2”------------------------- Select Input 2 (not switching Source) “3”------------------------- Select Input 3 (not switching Source) “UP”---------------------- Increment Input No. by 1 (Input1→Input2→Input3→Input1→...
  • Page 27: Cf_Input 2 Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.6.4 CF_INPUT 2 Command Command “CF_INPUT2_%1” [CR] “VIDEO” ---------------------------- Select Composite Video Input “YPBPR” --------------------------- Select Y/Pb/Pr Input “ANALOG” ------------------------- Select RGB Input Select Input 2 as well as Source specified in %1. (Available only in the normal Details Power ON status) Acceptable...
  • Page 28: Cf_System Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.6.6 CF_SYSTEM Command Command “CF_SYSTEM_%1” [CR] “VGA1” --------------------------- Select VGA1 “VGA2” --------------------------- Select VGA2 “XGA1” --------------------------- Select XGA1 “WXGA3” --------------------- Select WXGA3 “1080I” ------------------------ Select 1080i Input is “1035I” ------------------------ Select 1035i PC Analog “720P”...
  • Page 29: Screen Control Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command “CF_SCREEN_%1” [CR] “NORMAL” ---------------------- Select Normal mode “FULL” --------------------------- Select Full screen mode “WIDE” --------------------------- Select Wide(16:9) mode “ZOOM” -------------------------- Select Zoom mode “TRUE” -------------------------- Select True mode “CUSTOM”...
  • Page 30: Cf_Vscale Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.7.3 CF_VSCALE Command Command “CF_VSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “ 01” --------------------- 1 “ 02” --------------------- 2 “ 31” --------------------- 31 “ 32” --------------------- 32 “UP”...
  • Page 31: Cf_Hscale Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.7.5 CF_HSCALE Command Command “CF_HSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “ 01” --------------------- 1 “ 02” --------------------- 2 “ 31” --------------------- 31 “ 32” --------------------- 32 “UP”...
  • Page 32: Cf_Keystone Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.7.7 CF_KEYSTONE Command Command “CF_KEYSTONE _%1” [CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2 steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
  • Page 33: Cf_Screenaspect Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.7.11 CF_SCREENASPECT Command Command “CF_SCREENASPECT_%1”[CR] “43MODE” ÿ e ÿ e ÿ e ÿ e ÿ e ÿ e ÿ e Select 4:3 mode “169MODE” ÿ e ÿ e ÿ e ÿ e ÿ e ÿ e Select 16:9 mode “1610MODE”...
  • Page 34: Lamp Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Lamp Command 8.8.1 CF_LAMPMODE Command Command “CF_LAMPMODE_%1” [CR] “NORMAL” ------------------------ Set Lamp status to Normal mode “ECO1” ----------------------------- Set Lamp status to Eco1 mode “ECO2” ----------------------------- Set Lamp status to Eco2 mode “AUTO” ----------------------------- Set Lamp status to Auto mode Select Lamp mode (Available only in the normal Power ON status) Details The value set by this command is stored in EEPROM and the setting remains...
  • Page 35: Sound Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1” [CR] “000-063” --------------------------- Directly specify value of Volume. “UP” --------------------------------- Increment setting value of Volume by 1 “DN” --------------------------------- Decrement setting value of Volume by 1 Control level of Volume (Available only in the normal Power ON status) Set Volume Up/Down the same way as RC and also directly specify value of Details Volume.
  • Page 36: Setting Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_LANG Command Command “CF_LANG_%1” [CR] “ENG” --------------------------- Select English “DEU” --------------------------- Select German “FRA” --------------------------- Select French “ITA” ----------------------------- Select Italian “ESP” ---------------------------- Select Spanish “POR” --------------------------- Select Portuguese “NED” --------------------------- Select Dutch “SVE”...
  • Page 37: Cf_Disp Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.4 CF_DISP Command Command “CF_DISP_%1” [CR] “ON” ----------------------------- Set Display to On “CNTDWNOFF” --------------- Set Display to Count down Off “OFF” --------------------------- Set Display to Off “UP” --------------- Switch forward (On → Count down Off → Off → On → ---) “DN”...
  • Page 38: Cf_Logo Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.6 CF_LOGO Command Command “CF_LOGO_%1_%2” [CR] “0000 – 9999” ------------- Directly set Logo PIN code “OFF” ---------------------------Cancel Logo display “DFLT” ------------------------- Select Logo of Factory Default “USER” ------------------------ Select User “UP” ---------------------------- Select functions to choose forward (OFF →...
  • Page 39: Cf_Pipmaininp Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.9 CF_PIPMAININP Command Command “CF_PIPMAININP_%1_%2” [CR] “1” -------------------- Select Input 1 “2” -------------------- Select Input 2 “3” -------------------- Select Input 3 “ANALOG” --------------- Select Analog Input “VIDEO” ------------------- Select Composite Video Input “S-VIDEO” ---------------- Select S-Video input “YPBPR”...
  • Page 40: Cf_Pipposition Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.12 CF_PIPPOSITION Command Command “CF_PIPPOSITION_%1” [CR] “POS1” -------------------- Move main picture position to up “POS2” -------------------- Move main picture position to down “POS3” -------------------- Move main picture position to left “POS4” -------------------- Move main picture position to right “POS5”...
  • Page 41: Cf_Pipmodefree Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.15 CF_PIPMODEFREE Command Command “CF_PIPMODEFREE_%1” [CR] “USER1” --------------------------- Set User1 to Free status “USER 2” -------------------------- Set User2 to Free status “USER 3” -------------------------- Set User3 to Free status “USER 4” -------------------------- Set User4 to Free status “USER 5”...
  • Page 42: Cf_Filh Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.19 CF_FILH Command Command “CF_FILH_%1” [CR] “RST” ---------------------- Reset Filter used time Details Reset used time for filter of projector Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 8.10.20 CF_FILTIMER Command Command “CF_FILTIMER_%1” [CR] “0600”...
  • Page 43: Cf_Rcode Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.23 CF_RCODE Command Command “CF_RCODE_%1” [CR] “001” ------------------------------------ Select Code 1 “002” ------------------------------------ Select Code 2 “003” ------------------------------------ Select Code 3 “004” ------------------------------------ Select Code 4 “005” ------------------------------------ Select Code 5 “006” ------------------------------------ Select Code 6 “007”...
  • Page 44: Cf_P-Manetime Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.26 CF_P-MANETIME Command Command “CF_P-MANETIME_%1” [CR] “01” - ”30” ----------------------- Directly specify setting time by the minute “UP” ------------------------------- Increment value by 1 (Switched in 01→02→ --- → 30 → 01 order) “DN” ------------------------------ Decrement value by 1 (Switched in 30→29→...
  • Page 45: Cf_Ptimemode Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.30 CF_PTIMEMODE Command Command “CF_PTIMEMODE_%1” [CR] “COUNTUP” ---------------------- Set P-timer to Count up mode “COUNTDN” ---------------------- Set P-timer to Count down mode Select count up/down mode of P-timer. (Available only in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status.
  • Page 46: Cf_Pjpincode Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.34 CF_PJPINCODE Command Command “CF_PJPINCODE_%1” [CR] “0000 – 9999” ------------- Directly specify PJ PIN code Enter PIN code to cancel PIN code lock (Available only in the normal Power ON status) PIN code can not be changed. (Only PIN code lock is canceled.) *When PIN code Lock is enabled: PIN code is matched ------------------------- Command is valid (Acceptable) PIN code is mismatched -------------------- Command is invalid (Error code “102”)
  • Page 47: Cf_Delayctrl Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.10.37 CF_DELAYCTRL Command Command “CF_DELAYCTRL_%1” [CR] “OFF”---------- Set Video delay control to OFF “ON”------------ Set Video delay control to ON Select the mode of Video delay control (Valid only when in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
  • Page 48: Other Commands

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.11 Other Commands 8.11.1 CF_KEYEMU Command Command “CF_KEYEMU_%1” [CR] “RIGHT” ---------------- Move Pointer rightward in On-Screen Display Menu “LEFT” ------------------ Move Pointer leftward in On-Screen Display Menu “UP” ---------------------- Move Pointer to upward On-Screen Display Menu “DN”...
  • Page 49: Cf_Power Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 8.11.3 CF_POWER Command Command “CF_POWER_%1” [CR] “ON” ----------------------------- Power ON “OFF” --------------------------- Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. * Error Code is returned in some projector statuses, which indicates the command is impossible to be executed.
  • Page 50: Status Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications Status Read Command 9.1 Format PC issues commands in format as below: “CR_ COMMAND” [CR] Command: String When projector receives the appropriate command, it returns the required data as a string. “000_” %1 [CR] %1: Required Data (String) When the received data cannot be decoded, the projector returns “?”...
  • Page 51: Image Status Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.4 Image Status Read Command 9.4.1 CR_BRIGHT Command Command “CR_BRIGHT” [CR] Details Get user controlled value of Brightness Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code” [CR] 9.4.2 CR_CONT Command Command “CR_CONT” [CR] Details Get user controlled value of Contrast Acceptable...
  • Page 52: Cr_Gamma Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.4.6 CR_GAMMA Command Command “CR_GAMMA” [CR] Details Get user controlled value of Gamma Acceptable “000_%1” [CR] Response “000 – 015” Unacceptable “Error Code” [CR] 9.4.7 CR_WBAL-R Command Command “CR_WBAL-R” [CR] Details Get user controlled Red value of White Balance Acceptable “000_%1”...
  • Page 53: Cr_Offset-R Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.4.11 CR_OFFSET-R Command Command “CR_OFFSET-R” [CR] Details Get user controlled Red value of Offset Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code” [CR] 9.4.12 CR_OFFSET-G Command Command “CR_OFFSET-G” [CR] Details Get user controlled Green value of Offset Acceptable “000_%1”...
  • Page 54: Cr_Image Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.4.16 CR_IMAGE Command Command “CR_IMAGE” [CR] Details Get image setting status Acceptable “000_%1” [CR] “DYNAMIC” -------------------------------- Dynamic “STAND” ------------------------------------ Standard “REAL” ------------------------------------ Real “NATURAL” -------------------------------- Natural “CINEMA” ---------------------------------- Cinema “CUSTOM1” ------------------------------- “Image1” “CUSTOM2” ------------------------------- “Image2” “CUSTOM3”...
  • Page 55: Pc Adjust Status Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] “0000 – 0031” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input) “?”...
  • Page 56: Cr_Ddots Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.5.6 CR_DDOTS Command Command “CR_DDOTS” [CR] Details Get value of Display Dots Acceptable “000_%1” [CR] “0100 – nnnn” (nnnn = Total Dots – Position H) Response “Error Code” [CR] ---- When command is not available in the Unacceptable given condition (such as being selected input “?”...
  • Page 57: Video Status Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get selected current signal. Auto detected signal is returned in Auto mode Details Only available when Input is Y,Pb/Cb,Pr/Cr, S-Video or Video. (This is not the case for PC-Analog and HDMI signals) Acceptable “000_%1”...
  • Page 58: Input Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.7 Input Read Command 9.7.1 CR_INPUT Command Command “CR_INPUT” [CR] Details Get selected INPUT No. Acceptable “000_%1” [CR] Response “1 – 3” Unacceptable “Error Code” [CR] 9.7.2 CR_SOURCE Command Command “CR_SOURCE” [CR] Details Get selected source Acceptable “000_%1”...
  • Page 59: Cr_Srcinp3 Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.7.5 CR_SRCINP3 Command Command “CR_SRCINP3” [CR] Details Get Source of INPUT3 Acceptable “000_%1” [CR] “VIDEO” ----------------------- in Video mode Response “S-VIDEO” -------------------- in S-video mode “YPBPR” ---------------------- in Y,Pb/Cb,Pr/Cr mode Unacceptable “Error Code” [CR] 9.7.6 CR_SYSTEM Command Command...
  • Page 60: Cr_Syslist Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.7.7 CR_SYSLIST Command Command “CR_SYSLIST” [CR] Details Get possible systems for System list Acceptable “000_%1_%2_---_%x” [CR] Error Code “101” is returned for no signal. Otherwise following values are returned according to Source. When input is PC-Analog; “XGA1”...
  • Page 61: Screen Status Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.8 Screen Status Read Command 9.8.1 CR_SCREEN Command Command “CR_SCREEN” [CR] Details Get selected screen image size Acceptable “000_%1” [CR] “NORMAL” ---------------------- Normal mode “FULL” --------------------------- Full screen mode “WIDE” --------------------------- Wide(16:9) mode “TRUE” --------------------------- True mode Response “ZOOM”...
  • Page 62: Cr_ Kystnmode Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.8.6 CR_ KYSTNMODE Command Command “CR_KYSTNMODE” [CR] Details Get setting status of Keystone Store Mode Acceptable “000_%1” [CR] “STR” ---------------------- Store mode is “Store” Response “RST” ---------------------- Store mode is “Reset” Unacceptable “?” [CR] -------------------- When unknown command is received 9.8.7 CR_CEIL Command Command...
  • Page 63: Lamp Status Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get information of Lamp Replacement time Acceptable “000_%1” [CR] “1Y” ----------------- indicates over lamp replacement time Response “1N” ----------------- indicates under lamp replacement time Unacceptable “?”...
  • Page 64: Cr_Projh Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.9.6 CR_PROJH Command Command “CR_PROJH” [CR] Details Get total running time of Projector (in hours) Acceptable “000_%1” [CR] Response “0000000 – 0099999” Unacceptable “Error Code” [CR] 9.9.7 CR_HMLAMP Command Command “CR_HMLAMP” [CR] Details Get total lamp number Acceptable “000_%1”...
  • Page 65: Sound Status Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME” [CR] Details Get volume value by user control Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code” [CR] 9.10.2 CR_MUTE Command Command “CR_MUTE” [CR] Details Get setting status of Sound Mute.
  • Page 66: Setting Status Read Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG” [CR] Details Get selected language Acceptable “000_%1” [CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
  • Page 67: Cr_Logo Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.5 CR_LOGO Command Command “CR_LOGO” [CR] Details Get setting status of Logo Acceptable “000_%1” [CR] “DFLT” ----------------------------- Default Logo is enabled Response “USER” --------------------------- User is enabled “OFF” ------------------------------ Logo is disabled Unacceptable “Error Code” [CR] 9.11.6 CR_LOGOLOCK Command Command “CR_LOGOLOCK”...
  • Page 68: Cr_Pipmaininp Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.9 CR_PIPMAININP Command Command “CR_PIPMAININP” [CR] Details Get Input and Source for “Picture in Picture”. (Main picture) Acceptable “000_%1_%2” [CR] “1” -------------------- Input1 is selected “2” -------------------- Input2 is selected “3” -------------------- Input3 is selected “ANALOG --------------------- ANALOG RGB is selected Response “VIDEO”...
  • Page 69: Cr_Pipframelock Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.12 CR_PIPFRAMELOCK Command Command “CR_PIPFRAMELOCK” [CR] Details Get setting status of Frame lock in “Picture in Picture”. Acceptable “000_%1” [CR] “MAIN” -------------------- Main picture is selected Response “SUB” --------------------- Sub picture is selected Unacceptable “Error Code”...
  • Page 70: Cr_Filtimer Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.17 CR_FILTIMER Command Command “CR_FILTIMER” [CR] Details Get Filter used time Acceptable “000_%1” [CR] “0600” ---------------------- Display massage by 600h used. “0900” ---------------------- Display massage by 900h used. “1200” ---------------------- Display massage by 1200h used. Response “1500”...
  • Page 71: Cr_Rcode Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.21 CR_RCODE Command Command “CR_RCODE” [CR] Details Get selected Remote Control Code Acceptable “000_%1” [CR] “001” --------------------------- Code 1 is selected “002” --------------------------- Code 2 is selected “003” --------------------------- Code 3 is selected “004” --------------------------- Code 4 is selected Response “005”...
  • Page 72: Cr_P-Manetime Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.25 CR_P-MANETIME Command Command “CR_P-MAETIME” [CR] Details Get setting time for starting Power Management function Acceptable “000_%1” [CR] Response “001 – 030” ----------------------- 1 to 30 minutes Unacceptable “Error Code” [CR] 9.11.26 CR_STANDBYMODE Command Command “CR_STANDBYMODE”...
  • Page 73: Cr_Ptimer Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.30 CR_PTIMER Command Command “CR_PTIMER” [CR] Details Get setting status of P-timer Acceptable “000_%a” [CR] “ON” -------------------- P-timer is activated Response “STOP” ---------------- P-timer is temporarily suspended “OFF” ------------------ Exit P-timer function Unacceptable “Error Code” [CR] 9.11.31 CR_PTIME Command Command “CR_PTIME”...
  • Page 74: Cr_Pjlockmenu Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.35 CR_PJLOCKMENU Command Command “CR_PJLOCKMENU” [CR] Details Get ON/OFF setting status of PIN code lock on menu Acceptable “000_%1” [CR] “ON1” -------------------- PIN code lock ON 1 is set on the menu Response “ON2” -------------------- PIN code lock ON 2 is set on the menu “OFF”...
  • Page 75: Cr_Testpat Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.11.39 CR_TESTPAT Command Command “CR_TESTPAT” [CR] Details Get setting status of Test pattern Acceptable “000_%1” [CR] “COLOR” ---------------------- Color bar is displayed “GRAD1” ---------------------- 16step(white→black) is displayed “GRAD2” ---------------------- 16step(white←black) is displayed “GRAD3” ---------------------- 16step(white↓black) is displayed Response “GRAD4”...
  • Page 76: Other Status Read Commands

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.12 Other Status Read Commands 9.12.1 CR_STATUS Command COMMAND “CR_STATUS” [CR] Get operating status of Projector Detail Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
  • Page 77: Cr_Tempfail Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.12.5 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside a projector when abnormal temperature status Details occurs. It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp.
  • Page 78: Cr_Temp Command

    PLC-WM4500/WM4500L Expand Serial Command Functional Specifications 9.12.6 CR_TEMP Command Command “CR_TEMP” [CR] Get the current temperature information inside a projector. Details It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp. (External temp.) %2 ------------------ Sensor 2 temp.