Appliance details
2
Appliance
details
2,1
Features
Burner output proportional
to hot water flow demand
for maximum energy efficiency
Stainless
steel burners with stabilized
blue flame
Built-in corrosion
resistant draft diverter
Adjustable
water flow restrictor
to ensure that water
flow demand will not exceed the heating capacity
of
the heater
• Safety thermocouple
at pilot burner
• Automatic
overheating
protection
shut-off sensor
• Copper
heating coils for endless
supply of hot water
•
Easily removable
one-piece
cover
•
Easy one person installation
•
Easy Pilot
Flame
Ignition
with
push
button
piezo
ignition.
BOSCH
is
constantly
improving
its
products,
therefore
specifications
are
subject to change
without
prior notice.
2,2
AQ125
BO specifications
(Technical
data)
Approved
in US/Canada
Capacity
Maximum
flow
rate: 3.7
GPM
(14
I/min)
at a 45°F
(25°C)
rise.
Maximum output
101,772 Btu/h (29.8 kW)
Maximum input
117,000 Btu/h (34.3 kW)
Efficiency in %
Recovery efficiency 80%
Min. Output
28,000 Btu/h (8.2 kW)
Gas Requirement
Gas connection
(inches) - 3/4"
Inlet gas pressure
under maximum operation*
•
Propane:
10.5" - 14" water column
•
Natural Gas: 5.7" - 14" water column.
* To
measure
Gas
Pressure,
see
Measuring
Gas
Pressure, chapter
3.6.
Water
•
Hot water connection
(inches) - 1/2"
• Cold water connection
(inches) - 1/2"
• Water
valve material: Polymer (PPS) (Polypropylene
Sulfid)
•
Minimum water flow: 0.5 gallon/minute
(1.9 I/m)
•
Minimum
recommended
water
pressure:
30
PSI
(2.07 bar)
• Connections:
-
Bottom of heater
Dimensions
•
Depth (in): 10.5" (265 mm)
• Width
(in): 18.25" (460 mm)
•
Height (in): 36.75"
(936 mm)
• Weight:
64 pounds
(29 kg).
Gas types
Natural Gas.
LP Gas
Safety
devices
•
Flame failure device (ionization
flame rod sensor)
•
Pressure relief valve (supplied
with heater)
• Over heat prevention
(temperature
limiter).
Water
resistant
IP X5 (protection
against water drops).
4
8 716 473 147