Craftsman 919.167220 Owner's Manual
Craftsman 919.167220 Owner's Manual

Craftsman 919.167220 Owner's Manual

Permanently lubricated single stage portable
Hide thumbs Also See for 919.167220:

Advertisement

Available languages

Available languages

Owner's
Manual
I CRRFTSMRN°I
Permanently
Lubricated
Single Stage
Portable
AiR COMPRESSOR
Safety
Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Troubleshooting
Repair
Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman
website:
www.sears.com/craftsman
D26543
Rev. 3 9/23/02

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 919.167220

  • Page 1 • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D26543 Rev. 3 9/23/02...
  • Page 2: Table Of Contents

    WAR RANTY ..........SPECiFiCATiON CHART ........SAFETY GUiDELiNES ........GLOSSARY ..........ACCESSORIES .......... DUTY CYCLE ..........ASSEMBLY ..........iNSTALLATiON ........11-12 OPERATION .......... 13-15 MAINTENANCE ........16-17 SERVICE AND ADJUSTMENTS ......18-19 STORAGE ..........TROUBLESHOOTING GUIDE ......21-23 REPAIR PARTS ........
  • Page 3: Specification Chart

    Model No. 919-167220 Max. Developed Bore 2.38" Stroke 1.35" Voltage-Single Phase 120V/60HZ Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig This manual contains information that is important for you to know and understand.
  • Page 4 Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. WARNING: Risk of explosion or fire How To Prevent What Could Happen it is normal for electrical contacts...
  • Page 5 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent it What Could Happen Drain tank daily or after each use. If Failure to properly drain condensed water from tank,...
  • Page 6 WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT iT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, if it is not used properly Never operate compressor with...
  • Page 7 WARNING: RISK OF BURNS I ,_.., WHAT CAN HAPPEN HOW TO PREVENT iT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 UNSAFE OPERATION [_,[ WARNING: RiSK WHAT CAN HAPPEN HOW TO PREVENT IT Review and understand all instructions Unsafe operation of your air compressor and warnings in this manual. could lead to serious injury or death to Become familiar with the operation you or others.
  • Page 9: Glossary

    Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    Contents of Carton Assemble Wheels 1 - Air Compressor Rubber Wheels Feet 2 - Shoulder Bolts, 3/8-16 2 - Hex Nuts, 3/8-16 2 - Rubber Bumpers 2 - Screws, 1/4-20 x .75 Tools Required for Assembly 1 - 9/16" socket or open end wrench Wheel Shoulder Bolt 1 - 1/2"...
  • Page 11: Installation

    HOW TO SET UP YOUR iMPORTANT: The outlet being used must be installed and grounded in UNiT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a clean, has the same configuration dry and well ventilated area.
  • Page 12 Extension Cords Voltage and Circuit Protection Refer to the Parts Manual for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Certain air compressors can be and overheating.
  • Page 13: Operation

    Know Your Air Compressor READ THiS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Safety Valve Tank Pressure Gauge: The tank Description...
  • Page 14 How to Use Your Unit Cooling System (not shown): This compressor contains an advanced How to Stop: design cooling system. At the heart of this cooling system is an Set the On/Auto/Off lever to engineered fan. It is perfectly normal "OFF".
  • Page 15 Move the On/Auto/Off lever to Too much air pressure causes a "ON/AUTO" position. The hazardous risk of bursting. Check compressor will start. the manufacturer's maximum Run the compressor for 15 pressure rating for air tools and minutes. Make sure the drain accessories.
  • Page 16: Maintenance

    Customer Responsibilities Before Daily or after Every Every each each Yearly hours hours Check Safety Valve Drain Tank • Air Filter O(1) • Air compressor pump intake and exhaust valves • 1- more frequent in dusty or humid conditions To Check Safety Valve Unit cycles...
  • Page 17 iMPORTANT: Do not operate the Water wiU condense in the air compressor with the air filter removed. tank. if not drained, water will corrode and weaken the air tank If dirty, rinse air filter with warm causing a risk of air tank rupture. water and squeeze dry.
  • Page 18: Service And Adjustments

    Unscrew the check valve (turn Unit cycles automatically when counterclockwise) using a 7/8" power is on. When doing open end wrench. Note the Maintenance, you may be exposed orientation for reassembly. to voltage sources, compressed Using a screwdriver, carefully or moving parts. Personal injuries push the valve disc up and can occur.
  • Page 19 Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. Unplug compressor. Remove the outlet pressure gauge and quick connect (if equipped) from the regulator. Remove the regulator.
  • Page 20: Storage

    Before you store the air compressor, Water will make sure you do the following: condense in the air tank. if not drained, water will Review the "Maintenance" corrode and weaken the air tank section on the preceding pages causing a risk of air tank rupture. and perform scheduled maintenance as necessary.
  • Page 21: Troubleshooting Guide

    Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Persona[ injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. CAUSE PROBLEM CORRECTION Pressure switch does not...
  • Page 22 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 23 PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Let motor cool off and Motor overload protection run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
  • Page 24: Repair Parts

    Air Compressor Model Number 919.167220 1, Torque 15-25 In-Lbs 35 Torque 100-120 In-Lbs Torque 5-7 Ft-Lbs Torque 15-25 In-Lbs 24 j 51 ¸ D26543 24- ENG...
  • Page 25 3/8" AC-0774 Isolator (3 used) AC-0292 Outlet Tube SSP-7821-1 Nut Tubing 3/8" SSG-3105 O-Ring Pump Assembly LA-3069 Label, Craftsman LA-3027 Label, Drain Tank LA-3108 Label, Hot Surface SST-107 Recess Rubber Bumper (2 used) SSF-630 Screw (2 used) D23571 Label, Compressor...
  • Page 26 Air Compressor Model Number 919.167220 85 Torque 7-10 Ft-Lbs Torque 51-63 In-Lbs Torque 42-48 In-Lbs 78\\ Torque 100-120 70 7 In-Lbs \\\\\\\ 73 Torque 100-120 In-Lbs D26543 26- ENG...
  • Page 27 Air Compressor Model Number 919.167220 PART NUMBER DESCRIPTION SSF-586 Screw 1/4 - 20 UNC x .75 AC-0108 SSF-615 Screw 1/4 - 20 UNC Z-AC-0107 Eccentric Bearing Z-D23360 Motor >x 78 Cylinder Sleeve > 79 Connecting Rod Assembly >x 79-2 Formed Compression Ring >...
  • Page 28: Espa_Iol

    GARANTIA ............CUADRO DE ESPECIFICACIONES ........DEFINICIONES DE NORMAS DE SEGURIDAD ......IMPORTANTES INSTRUCCIONES DE SEGURIDAD ..... 29-34 GLOSARIO ............ACCESORIOS ............ ClCLO DE SERVlCIO ..........ENSAMBLADO ............ INSTALACION ..........37-38 OPERACION ........... 39-41 MANTENIMIENTO ..........42-43 SERVICIOS Y REGULACIONES ........
  • Page 29 Modelo N ° 919-167220 Max. HP desarrollado Di&metro interior 2,375 pulg. (60,4 mm) Carrera 1,35 pulg. (34,3 mm) Tensi6n monof&sica 120V/60HZ Circuito minimo requerido Fusibles de Retardo Tipo de fusible Capacidad de aire en el tanque 22 Galones (83,3 litros) Presi6n de corte de entrada Presi6n de corte de salida SCFM a 40 psig...
  • Page 30 GUARDE ESTAS |NSTRUCC|ONES LA OPERACION O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRIAN OCASIONAR SERIAS LESIONES Y DANOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. ADVERTENCIA: RIESGO DE EXPLOSION O INCENDIO i, COMO PREVENIRLO? i.QUE PUEDE OCURRIR?
  • Page 31 ADVERTENCIA: RIESGO DE EXPLOSION TANQUE AIRE: SIGUIENTES CONDICIONES PODRIAN, CAUSAR DEBIMTAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSION VIOLENTA, DANOS A LA PROPIEDAD O SERIAS LESIONES. _QU_ PUEDE OCURRIR? _C6MO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamente o despu_s en el tanque, siendo la causa del 6×ido...
  • Page 32 ADVERTENClA: RIESGO DE DESCARGA ELECTRICA I _J.J I i.QUE PUEDE OCURRIR? i.COMO PREVENIRLO? Su compresor de aire est_ accionado Jam&s opera el compresor a la intemperie cuando est& Iloviendo o en condiciones electricidad. Como cualquier otto dispositivo humedad. el6ctrico impulsado el6ctricamente, si no se Io utiliza...
  • Page 33 ADVERTENCIA: RIESGO DE QUEMADURAS I ,,,_V _.QU_: PUEDE OCURRIR? _,C6MO PREVENIRLO? Tocar el metal expuesto tel come el cabezal Jam&s toque partes de metal expuestas en el compresor durante o inmediatamente despu&s del compresor o los tubos de salida del escape, de la operaci6n, emcompresor permanecer_...
  • Page 34 ADVERTENCIA: RIESGO DE OPERACION INSEGURA _.QUE PUEDE OCURRIR? $06MO PREVENIRLO? La operacion insegura de su compresor de aire Revise y comprenda todas las instrucciones podria ocasionarle serias mesiones o la muerte advertencias contenidas en este manual. a usted u otros. Familiaricese con los m_todos de operaci6n...
  • Page 35 Presi6n minima de corte: Cuando el Familiaricese con los siguientes t6rminos, motor est& apagado, la presi6n del tanque antes de operar la unidad: de aire baja a medida que usted continQa CFM: (Cubic feet per minute) Pies cQbicos usando su accesorio. Cuando la presi6n pot minuto.
  • Page 36 Ensamble de las ruedas Contenido de la caja 1- Compresor de aire Ser_ necesario 2- Ruedas soportar un lado del equipo cuando se instalan 2- Pernos con resalto, 3/8 - 16 ruedas porque el compresor tender_ 2- Tuercas hexagonales, 3/8 - 16 voltearse.
  • Page 37 C()MO PREPARAR LA UNIDAD IMPORTANTE: El tomacorriente que sera utilizado debera haber sido conectado tierra conforme a todos los c6digos Ubicaci6n del compresor de aire locales y ordenanzas. Ubique al compresor de aire en una zona limpia, seca y bien ventilada. El compresor de AsegOrese de que el tomacorriente que aire debe estar instalado - per Io menos - a sera utilizado tenga la misma...
  • Page 38 Cables de extensi6n el_ctrica Protecci6n del voltaje y del circuito No se recomienda la utilizaci6n de cables Acerca del voltaje y la minima cantidad de de extensi6n el6ctrica. El uso de cables circuitos requeridos, refi6rase al Manual de extensi6n el6ctrica originara una caida de piezas.
  • Page 39 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 40 Sistema de enfriamiento (no mostrado): C6mo utilizar su unidad Este compresor contiene un sistema de avanzada para el control de enfriamiento. C6rno detenerla: En el nOcleo de este sistema de Coloque la posici6n de la Ilave enfriamiento hay un ventilador interruptora On/Auto/Off en la...
  • Page 41 Mueva la palanca On/Auto/Off a la Demasiada posicion "ON/AUTO". El compresor se presi6n de aire podr_ ser la causa de riesgo de explosi6n. pondra en marcha. Verifique los valores de m_xima presi6n Haga funcionar el compresor durante 15 dados pot el fabricante de las herramientas minutos.
  • Page 42 Responsabilidades del cliente Antes Diariamente Cada Cada de cada Anualmente o luego de cada uso horas horas Verifique la vAlvula de seguridad • ® Drenaje del tanque ® Filtro de aire O(1) Valvulas de entrada y escape de ® la bomba del compresor de aire 1- MAs frecuente en condiciones polvorientas...
  • Page 43 Una vez drenada el agua, cierre Si esta sucio enjuague el filtro de aire valvula de drenaje (girando en con agua tibia y exprimalo hasta que sentido horario). Ahora el compresor seque. de aire podrA ser guardado. Reponga el filtro de aire y su ret6n. NOTA: Si el filtro de aire esta sumamente NOTA: Si la v&lvula de drenaje fuera del...
  • Page 44 Desenrosque la v&lvula de retenci6n La unidad cicla autom_ticamente girandola hacia la izquierda usando en cuanto la energia el_ctrica es una Ilave de boca de 7/8 plug. conectada. AI efectuar el (22 mm). Tome nota de la mantenimiento, usted quedar_ orientaci6n para volverla a ensamblar.
  • Page 45 Ensamble el regulador y ori6ntelo de Para reemplazar el regulador acuerdo a io mostrado. Libere toda la presi6n del aire del tanque. Vea "Drenaje del tanque" en la secci6n "Mantenimiento". Desenchufe el equipo. Regulador Usando una Ilave de tuercas ajustable retire el medidor de salida de presi6n y la conexi6N rApida del regulador la tiene).
  • Page 46 Antes de guardar su compresor de aire, , ,= Elaguase "-- condensadentro asegOrese de hacer Io siguiente: del tanque de aire. Si no se drena, ella Revise la secci6n "Mantenimiento" corroer_ debilitando la paredes del de las paginas precedentes y ejecute tanque de aire, originando un riesgo de...
  • Page 47 El desarrollo de reparaciones puede exporter a sitios con corriente viva, partes en movimiento o fuentes aire comprimido que podrian ocasionar lesiones personales. Antes intentar reparacibn alguna, desenchufe el compresor de aire y purgue toda la presi6n de aire del tanque. CORRECCK)N PROBLEMA CAUSA...
  • Page 48 PROBLEMA CAUSA CORRECCION Si hubiese una caida excesiva de La lectura de la Es normal que ocurra alg_n presi6n durante el uso del descenso en la presi6n. presi6n sobre un accesorio, ajuste el regulador de man6metro acuerdo a las instrucciones de la viene equipado secci6n Operaci6n.
  • Page 49 PROBLEMA CAUSA CORRECCION El motor no El interruptor de protecci6n Deje enfriar el motor y el funciona. interruptor de sobrecarga se obrecarga del motor se ha abierto. reajustarA automAticamente. El motor arrancara automaticamente La presi6n del tanque excede la presi6n de "corte mAximo" cuando la presi6n del tanque caiga pot debajo de la presi6n de corte del interruptor...
  • Page 50: Notes/Notas

    D26543 50- S P...
  • Page 51 51- S P D26543...
  • Page 52 Your Home For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.

Table of Contents