Air Cooling System - Craftsman 580.326300 Owner's Manual

6300 watt electric start ac generator
Hide thumbs Also See for 580.326300:
Table of Contents

Advertisement

Available languages

Available languages

WARNING
DO NOT touch hot surfaces.
Allow equipment to cool before touching.
The generator must be at least 5 feet from structures having
combustible walls and/or other combustible materials.
Keep at least 3 feet of clearance on all sides of generator
for adequate cooling, maintenance and servicing.
In the State of California a spark arrester is required by law
(Section 4442 of the California Public Resources Code).
Other states may have similar laws. Federal laws apply on
federal lands. If you equip the muffler with a spark arrester,
it must be maintained in effective working order.
Clean and inspect the spark
attester
as foltows:
1.
To remove
muffler
heat shield from muffler,
remove
four screws
that connect
guard to muffler
bracket.
2.
Remove
four screws
that attach spark
attester
screen.
Spark
Attester
Screen
eat Shield
.
inspect screen and replace if torn, perforated or
otherwise damaged. DO NOT use a defective
screen. If screen is not damaged, clean it with
commercial solvent.
4.
Reattach screen and muffler guard.
Air Cooling
System
Over time debris may accumulate in cylinder cooling
fins and cannot be observed without partial engine
disassembly. For this reason, we recommend you
have an authorized Sears service dealer clean the
cooling system per recommended
intervals (see
"Maintenance Schedule" on page 13). Equally
important is to keep top of engine free from debris.
See "Generator Cleaning".
CLEAN
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents