MODELS AY-XM7CR AY-XM9CR AY-XM12CR Air Conditioner AY-XPM7CR AY-XPM9CR AY-XPM12CR MULTI SPLIT TYPE ROOM AIR CONDITIONER MEHRFACH-AUFTEILUNGS- ZIMMER-KLIMAGERÄT CLIMATISEUR DE SALLE DE TYPE A DIVISION MULTIPLE • Uses ozone layer friendly refridgerant R-410A. • Verwendet das die Ozonschicht schonende ACONDICIONADOR DE AIRE PARA Kühlmittel R-410A.
ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. CONTENTS • PRECAUTIONS ........... E-1 • ONE-HOUR OFF TIMER ..... E-13 • ADDITIONAL NOTES ON OPERATION ..... E-3 • TIMER OPERATION ......E-14 •...
PRECAUTIONS CAUTIONS FOR USE Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. Do not operate the buttons with wet hand. It may cause electric shock. For safety, turn the circuit breaker off when not using the unit for an extended period of time.
ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE • The built-in protective de- INDOOR TEMP. OUTDOOR TEMP. vice may prevent the unit 32˚C D.B. 43˚C D.B. from operating when used upper limit 23˚C W.B. out of this range. COOLING 21˚C D.B. 21˚C D.B.
SETTING DUST COLLECTION FILTER AND DEODORANT FILTER (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) The dust collection filter and the deodorant filter are packed as accessory of this unit. During operation of the air conditioner, the filters remove dust and tobacco smoke from the air and discharges clean air. Take out the air filters.
USING THE REMOTE CONTROL LOADING BATTERIES Use two size-AAA (R03) batteries. Remove the remote control cover. Remote control cover Insert batteries in the compart- ment, making sure the ± and — polarities are correctly aligned. • The display indicates "AM 6:00"...
CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
BASIC OPERATION Press the MODE button to select the op- eration mode. AUTO HEAT COOL Press the ON/OFF button to start opera- tion. • The red OPERATION lamp ( ) on the unit DISPLAY will light. FULL Press the THERMO. button to set the de- POWER sired temperature.
TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature and outdoor temperature when the unit is turned on. Modes and Temperature Settings • During operation, if the outdoor temperature changes, the temperature settings will auto- matically slide as shown in the chart.
ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION The air flow direction is automatically preset in each mode as follows for optimum comfort: COOL and DRY modes Horizontal air flow HEAT mode Diagonal air flow HOW TO ADJUST THE AIR FLOW DIRECTION Adjustment range Press the SWING button on the remote control once.
FULL POWER OPERATION In this operation, the air conditioner works at maximum power to makes the room cool or warm so rapidly that you can use it just after you come home. To activate the FULL POWER operation, press the FULL POWER button during operation.
TIMER OPERATION NOTE: Before setting the timer, make sure the clock is properly set with the current time. TIMER OFF Press the TIMER OFF ( ) button. The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time.
TIMER ON Press the TIMER ON ( ) button. The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the de- sired time. (The time can be set in 10-minute increments.) Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
TIPS ABOUT PLASMACLUSTER OPERATION (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) The ionizer inside the air conditioner will release cluster ions, which are collective mass of positive and negative ions, into the room. The cluster ions reduce airborne mold fungus and deodorize/decompose odor- causing molecules.
PLASMACLUSTER OPERATION (only for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) You can choose PLASMACLUSTER AUTO OPERATION, AIR CLEAN OPERATION or REFRESHING OPERATION When the unit is in operation, press the PLASMACLUSTER button to select the mode. PLASMACLUSTER AUTO AIR CLEAN REFRESHING CANCEL AUTO • In CLEAN operation, blue...
AUXILIARY MODE Use this mode when the remote control is not available. TO TURN ON Lift the front panel of the indoor unit and press the AUX. button on the operation panel. • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
MAINTENANCE (for models AY-XM7CR/AY-XM9CR/AY-XM12CR) Be sure to turn off the air conditioner and turn off the circuit breaker before perform- ing any maintenance. CLEANING THE FILTERS The air filters should be cleaned every two weeks. TURN OFF THE UNIT REMOVE THE FILTERS 1 Lift the open panel.
MAINTENANCE (for models AY-XPM7CR/AY-XPM9CR/AY-XPM12CR) Be sure to turn off the air conditioner and turn off the circuit breaker before perform- ing any maintenance. CLEANING THE FILTERS The air filters should be cleaned every two weeks. TURN OFF THE UNIT REMOVE THE FILTERS 1 Lift the open panel.
Page 22
CLEANING THE DEODORANT FILTER (GREEN) The filter should be cleaned every 3~6 months REMOVE THE AIR FILTERS CLEAN THE DEODORANT FILTER 1 Take off the deodorant filter from the air filters. 2 Soak the deodorant filter in mild detergent dilution for 10 to 20 minutes. Rinse thoroughly with water, dry completely Filter stopper under sunlight.
BEFORE CALLING FOR SERVICE The following conditions do not denote equipment malfunctions UNIT DOES NOT OPERATE WATER VAPOUR The unit will not operate if it is turned on • In the COOL and DRY operation, water immediately after it is turned off. The unit will not vapour can sometimes be seen at the air operate immediately after the mode is changed.
Page 24
If the unit appears to be malfunctioning, check the following points before calling for service. IF THE UNIT FAILS TO OPERATE Check to see if the circuit breaker has tripped or the fuse has blown. IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY Check the outdoor unit to Check the thermostat is Check the filters.