Download Print this page

Craftsman 919.166442 Owner's Manual

Permanentjy lubricated tank mounted air compressor
Hide thumbs Also See for 919.166442:

Advertisement

Available languages

Available languages

Quick Links

Owner's
Manuam
I(:RRFTSMnN°I
PermanentJy
Lubricated
Tank Mounted
AIR COMPRESSOR
ModeJ No.
o
o
o
o
o
o
o
Safety
Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Repair
Parts
CAUT|ON:
Read the Safety Guidelines
and All instructions
CarefulIy Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
IL (}0179 U.S.A.
Visit our Oraftsman
website:
www, sears,com/craftsman
A13640 R_v. 0 11/16/0s

Advertisement

loading

Summary of Contents for Craftsman 919.166442

  • Page 1 Safety Guidelines Assembly Operation Maintenance Service and Adjustments Repair Parts CAUT|ON: Read the Safety Guidelines and All instructions CarefulIy Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL (}0179 U.S.A. Visit our Oraftsman website: www, sears,com/craftsman A13640 R_v. 0 11/16/0s...
  • Page 2 FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge. Contact your nearest Sears Service Center (1-800-4-MY-HOME <e) to arrange for repair, or return the Air...
  • Page 3 " m ± ( )(h, Model No. 919,166442 Running HP Sore 1.875" Stroke 1.25" Voltage-Single Phase 120V/60HZ/1 PH Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig Refer to Giossary for abbreviations.
  • Page 4 iiii_, ..Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. iiiiii_, WARNING: Risk of explosion or fire ,._._ How To Prevent it What Could Happen It is normal...
  • Page 5 111¸¸ 11!1 iiiiiiiii_, III! WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. Now "re Prevent It What Coumd Hal2pen Drain tank daily or after each use.
  • Page 6 WARNING: Risk of Electrical Shock I _.._ How To Prevent mt What Oeuld Happen Your air compressor is powered Never operate the compressor outdoors eReetricity, Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with...
  • Page 7 WARNING: Risk of Burns What Could How To Prevent mt Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) How To Prevent What Could Happen Oil can leak or spill and could result Always piece COMPRESSOR on a in fire or breathing hazard; serious protective mat when transporting injury or death can result,...
  • Page 9 Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure CFM: Cubic feet per minute. at which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10 Remove unit from carton and discard a!l packaging. HOW TO SET UP YOUR iMPORTANT: The outlet being used must be installed and grounded in UNiT accordance with all local codes and ordinances. Location of the Air Compressor Locate the air compressor in a Make sure the outlet being used clean, dry and well ventilated area.
  • Page 11 Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the specification chart for the recommended. The use of extension voltage and minimum branch circuit cords wilI cause voltage to drop requirements. resulting in power loss to the motor and overheating.
  • Page 12 Know Your Air Compressor READ THiS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the !ocation of various controls and adjustments. Save this manual for future reference. Description of Operation Tank Pressure Gauge: The tank...
  • Page 13 Air Compressor Pump (not shown): Plug the power cord into the Compresses air into the air tank. correct branch circuit receptacle. Working air is not available until the (Refer to "Voltage and Circuit compressor has raised the air tank Protection" paragraph in the pressure above that required at the Installation section of this air outlet.
  • Page 14 How to Start: NOTE: Always operate the air compressor in wetI-ventilated areas Turn the On/Auto/Off lever free of gasoline or other combustible to "On/Auto" and allow tank vapors, if the compressor is being pressure to build. Motor will used to operate a sprayer DO NOT stop when tank pressure reaches place near the spray area.
  • Page 15 Customer Responsibilities Before Daily each or after each ® _heck Safety Valve :)rain Tank To Drain Tank Risk of Unsafe Operation, Unit Set the On/Auto/Off lever to cycmes automatically when power "Off". is on, When servicing, you may be exposed to vomtage sources, Turn the regulator knob counter- clockwise to set the outlet...
  • Page 16 AH maintenance and repair Unscrew the check valve (turn operations not misted must be counterclockwise) using a 7/8" performed by Trained Service open end wrench. Note the Technician, orientation for reassembly. Using a screwdriver, carefully push the valve disc up and down.
  • Page 17 Remove pump mounting screws To Replace Regulator securing pump (one on each Release all air pressure from air side). tank. See "To Drain Tank" in the Maintenance section. Carefully slide pump from brackets and out of the way. Unplug unit. Using an adjustable wrench or Using an adjustable wrench or 5/8"...
  • Page 18 Before you store the air compressor, Risk of Bursting, Water will make sure you do the following: condense in the air tank, If not Review the Maintenance section drained, water will corrode on the preceding pages and weaken the air tank causing a risk perform scheduled maintenance...
  • Page 19 _Risk of Unsafe Operation, Unit cycles automatically when power is on, When servicing, you may be exposed voltage sources, compressed air, or moving parts, Before servicing unit unplug or disconnect electrical suppmy to the air compressor, bleed tank of pressure, and allow the air compressor to cool PROBLEM...
  • Page 20 PROBLEM CAUSE CORRECTION Pressure reading it is normal for "some" if there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 21 PROBLEM CAUSE CORRECTION Motor will not Fuse blown, circuit breaker Check fuse box for blown run. tripped. fuse and repiace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
  • Page 22 Air Compressor Modet Number 919o166442 "37 Torque 3 6 ft Ibs A13640 22- ENG...
  • Page 23 A00600 Check Valve SSP=473 Nut Sleeve Assembly 5/16" CAC=1254 Isolator (4) SSF-621 Screw 1/4-14 x 5/8 (2) Pump Assembly LA-3069 Label, Craftsman LA-3027 Label, Drain Tank Eng/Spa LA-3108 Label, Hot Surface LA-3266 Label, Warning D23627 Label, Star Rating D28123 Pneumatic Tire 8 x 2-1/4...
  • Page 24 "o Torqueto 30-45in.dbs £ 28_._ Torqueto be handtighten to 10 in.dbs,max. / Torqueto © 49-55in.-Ibs...
  • Page 25 Air Compressor Modem Number 919,166442 PART NUMBER DESCRIPTION A10648 Shroud (right) A10492 Shroud (left) CAC-1196 Head ÷ CAC-1212 Tube Seal A05346 Outlet Tube Assembly ÷ Z-D24819 Head Gasket Z-A08548 Valve Plate Assembly ÷ Gasket Z-A04714 Sub Pump Assembly > Connecting Rod Assembly >+ Pre-Formed...
  • Page 26 TOTAL DE UN ANO DEL OOMPRESOR DE AmRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aMo de su fecha de compra, Sears, a su opciOn, Io reparara o reemptazara sin costo alguno.
  • Page 27 ii[, Modelo N ° 919o166442 HP de Trabajo Di_metro interior 1,875 pc (47,7mm) Carrera 1,25 po (31 ,Smm) Tensi6n monofAsica 120V/60HZ/1PH Circuito minimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire en el tanque 15 Galones (56,8 litros) Presi6n de corte de entrada Presi6n de corte de salida SCFM a 40 psig 4,9 Calibre de libras...
  • Page 28 GUARDE ESTAS |NSTRUCCiONES operaci6n o el mantenimiento inadecuados este producto poddan ocasionar serias lesiones y datios a la propiedad= Lea y comprenda todas advertencias e instrucciones de funcionamiento antes de utilizar este equipo= ADVERTENCIA: Riesgo de Explosi6n o Incendio puede occurrir c6mo preveniHo...
  • Page 29 ADVERTENCIA: Riesgo de E×plosi6n Tanque de aire: las siguientes condiciones podfian, causar el debilitamiento del tanque, determinar su explosi6n violenta, danes a la propiedad o serias lesiones. qu6 puede occurrir c6mo preveniHo Drenaje inadecuado del agaa condeneada Drene el tanqae diariamente o despa_e en el tanqae,...
  • Page 30 ADVERTENCIA: Riesgo Descarga ER_ctrica puede occurrir c6mo preveniHo Su cornpresor de aire est_ accionado Jam&s opere el compresor a la intemperie e_ectricidad= Como cualquier otro dispositivo cuando est& Iloviendo o en condiciones e!Sctrico impulsado el6ctricamente, si no se Uo humedad=Nunca opere el compresor sin sue...
  • Page 31 ADVERTENCmA: Riesgo de Quemaduras qu_ puede occurrir c6mo preveniHo Jam_s toque partes de metal e×pueetas en e_ Tocar eUmetaU e×puesto tal como el cabezal compresor dur_nte o inmediatamente despu6s de! compresor o los tubos de salida de! escape, de la operaci6n, eUcompresor permaeecer_ puede ocaeionarIe...
  • Page 32 ADVERTENOIA: Riesgo de Sepias Lesiones o DaSos a la Propiedad Transportar el ¢ornpresor (Fuego, hhaUaci6n, daSo a la superficie de vehicuUos) puede occurrir c6mo prevenirlo EUaceite puede derramarse y ello podfia Deposite el cornpreeor eobre aria affornbriHa resultar en serias fesiones o la muerte debido al protectora cuando Uotransporte,...
  • Page 33 FamiliaHcese con los siguientes t6rminos, usando su accesorio. Cuando la presi6n del tanque baja al valor fijado en f_brica antes de operar la unidad: come punto bajo, el motor volvera a CFM: (Cubic feet per minute) Pies cObicos arrancar autom_ticamente. La presion per minute.
  • Page 34 Desempaque Extraiga la unidad de su caja y descarte todas las partes de embalaje. come PREPARAR LA UN[DAD AsegOrese de que el tomacorriente que sera utilizado tenga la misma configuraci6n que el enchufe de Ubicaci6n de[ compresor de aire conexi6n a tierra. NO UTlUCE UN Ubique al compresor de aire en una ADAPTADOR.
  • Page 35 Cables de extensi6n em_ctdca Protecci6n del voJtaje y del circuito No se recomienda la utilizaci6n de cables Acerca del voltaje y la mfnima cantidad de extensi6n el6ctrica. El uso de cables circuitos requeridos, refi6rase al cuadro de especificaciones. de extensi6n el6ctrica originar_ una caida de tensi6n, Io que determinar_ p6rdida de potencia del motor as[ come compresores...
  • Page 36 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARiO Y SUS NORMAS DE SEGURiDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 37 Enchufe el cable de alimentaci6n en Bornba de compresi6n del aire {no mosttada}: Comprime el aire dentro del el recept&culo del ramal del circuito tanque. El aire de trabajo no se encuentra correcto. (Referirse al parrafo "Protecci6n disponible hasta que el compresor haya del voltaje y del circuito"...
  • Page 38 Responsabilidades dem ciiente Antes _iariamente cada ,_ luegede 3ada use ierifique la valvula de seguridad ::)renaje del tanque C6mo drenar eB tanque Riesgo de Operaci6n Coloque la palanca On/Auto/Off mnsegura. Cuando se reamizan trabajes la posiciSn "Off". de mantenimiento, usted puede estar Tire de la perilla del regulador y gire expuesto a fuentes...
  • Page 39 Todo tipo de mantenimiento Desenrosque la v_lvula de retencion operaciones de reparaci6n no gir_ndola hacia la izquierda usando mencionados, deber_n set efectuados una Ilave de boca de 7/8 plug. por personal t6cnico especializado. (22 mm). Tome nota de la orientaci6n para volverla a Riesgo de ensamblar.
  • Page 40 Saque los tornillos de montaje que Para reempBazar el regulador sujetan la bomba (uno en cada lado). Drene la presi6n del tanque de aire. Vea las instrucciones para el "Drenaje Saque la bomba de sus soportes desliz_ndola cuidadosamente. del tanque de aire" en la secci6n Mantenimiento.
  • Page 41 Antes de guardar su compresor de aire, Riesgo de asegOrese de hacer Io siguiente: Revise la secci6n Mantenimiento agua se condensa dentro del tanque las p_ginas precedentes y ejecute de aire. Si no se drena, ella corroer4 el mantenimiento programado debilitando la paredes del tanque...
  • Page 42 Riesgo de Operaci6n Insegura. La unidad arranca autom&ticamente cuando est4 enchufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente de aire comprimJdo o a piezas movibles. Antes de intentar hacer reparaciones, desconectar el comptesor del tomacorriente, drenar la presi6n de aire del tanque y esperar a que el compresor...
  • Page 43 PROBLEMA CAUSA CORRECCION Si hubiese una ca[da excesiva La lectura de la Es normal que ocurra alg0n de presi6n durante el uso del presi6n sobre un descenso en la presi6n. accesorio, ajuste el regulador de man6metro acuerdo alas instrucciones de la viene equipado secci6n Operaci6n.
  • Page 44 PROBLEMA CORRECCION CAUSA El motor no Verifique la ca}a de fusibles Fusible fundidol interrupter funciona. observando la existencia de fusibles autom_tico del circuito disparado, fundidos y sustit_yalos en caso de necesidad, Restablezcael inter_uptor automatico. No use un fusible o interruptorautom;Jtico con va!ores que exeedan los especificados para la rama de su circuito, Verifique el use del fusible adecuado,...
  • Page 45 45-SP A13640...
  • Page 46 A13640 46-SP...
  • Page 47 Contratos Protecci6n para Reparaciones Congratulations on making a smart Felicitac/ones par hacer una compra purchase. Your new Craftsman Crb product /ntel/gente. Su nueva unidad Craftsman _p esta is designed and manufactured for years diseRada y fabricada para a[ios de operaci6n of dependable operation.
  • Page 48 Your Home For repah- in your home -of all major brand appHiances, Hawn and garden equipment, or heating and cooHing systems, no matter who made it, no matter who so_d it! For the repHacement parts, accessories owner's manuaHs that you need to do-it-yourseHfi For Sears professionaH instaHHation of home appHiances and items Hikegarage door openers and water heaters.