Craftsman 919.167784 Owner's Manual

Permanently lubricated 2-stage twin v portable air compressor
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Owners Manual
I CRRFTSMRN°I
Permanently
Lubricated
2-Stage
Twin V
Portable
AIR COMPRESSOR
Model No.
919.167784
Safety Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Troubleshooting
Repair
Parts
CAUTION:
Read the Safety Guidelines
and All Instructions
Carefully
Before
Operating.
Sold by Sears Canada,
Inc. Toronto, Ont. M5B 2B8
N015838
Rev. 0
08/26/06

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 919.167784

  • Page 1 Owners Manual I CRRFTSMRN°I Permanently Lubricated 2-Stage Twin V Portable AIR COMPRESSOR Model No. 919.167784 • Safety Guidelines • Assembly • Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating.
  • Page 2: Installation

    WARRANTY ..........SPECIFICATIONS ........... SAFETY GUIDELINES-DEFINITIONS ......IMPORTANT SAFETY INSTRUCTIONS ......GLOSSARY ..........DUTY CYCLE ..........ACCESSORIES ..........ASSEMBLY ..........INSTALLATION ......... 10-11 OPERATION ........... 12-14 MAINTENANCE ......... 14-15 SERVICE AND ADJUSTMENTS ......16-17 STORAGE ..........TROUBLESHOOTING GUIDE ......19-21 REPAIR PARTS .........
  • Page 3 Model 919.167784 Bore 2.375" 0.54" Stroke High Pressure Low Pressure 1.45" Voltage/Hz-Single Phase Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity (Gallon) 145 PSIG Approximate Cut-in Pressure 175 PSlG Approximate Cut-out Pressure *5.8 SCFM @ 40 psig "5.1 SCFM @ 90 psig *Tested per ISO 1217...
  • Page 4: Risk Of Explosion

    RISK OF EXPLOSION OR FIRE WHAT CAN HAPPEN HOW TO PREVENT It is normal for electrical contacts Always operate the compressor in a well ventilated area free of within the motor and pressure switch to spark. combustible materials, gasoline, solvent vapors. If electrical sparks from compressor •...
  • Page 5 • Exposure to chemicals in dust Work in an area with good cross created by power sanding, sawing, ventilation. Read and follow the grinding, drilling, and other safety instructions provided on the construction activities may be label or safety data sheets for the harmful.
  • Page 6 Tires: • Over inflation of tires could result • Use a tire pressure gauge to check the tires pressure before each use in serious injury and property and while inflating tires; see the tire damage. sidewall for the correct tire pressure. NOTE: Air tanks, compressors similar equipment used to inflate...
  • Page 7 RISK FROM FLYING OBJECTS WHAT CAN HAPPEN HOW TO PREVENT The compressed air stream can Always wear certified safety cause soft tissue damage equipment: ANSI Z87.1 eye exposed skin and can propel dirt, protection (CAN/CSA Z94.3) chips, loose particles, and small with side shields when using the objects at high speed, resulting in...
  • Page 8: Operation

    RISK OF UNSAFE OPERATION WHAT HAPPEN HOW TO PREVENT • Unsafe operation of your • Review and understand compressor could lead to serious instructions and warnings in this injury or death to you or others. manual. • Become familiar with the operation and controls of the air compressor.
  • Page 9 RISK FROM NOISE HOW TO PREVENT WHAT CAN HAPPEN Always wear certified safety of use, noise from this product equipment: ANSI S12.6 ($3.19) • Under some conditions and duration [ • contribute to hearin 9 loss. hearin 9 protection. SAVE THESE INSTRUCTIONS FOR FUTURE low level the motor will restart auto- Become familiar with these terms...
  • Page 10: How To Set Up Your Unit

    This unit is capable of powering the following Accessories. The accessories available through the current Power and Hand Tool Catalog or full-line Sears stores. Accessories Refer to the selection chart located on • In Line Filter the unit to select the tools this unit is capable of powering.
  • Page 11: Specifications

    Voltage and Circuit Protection Plug Refer to the specification chart for the voltage and minimum branch circuit Grounded requirements. Outlets Certain compressors be operated on a 15 amp circuit if Grounding Pin the following conditions are met. Voltage supply to circuit must Inspect the plug and cord before comply with the National Electrical...
  • Page 12: Know Your Air Compressor

    Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Regulator: Controls the air pressure Description of Operation shown on the outlet pressure gauge.
  • Page 13: How To Use Your Unit

    Air Compressor Pump (not shown): Break-in Procedure Compresses air into the air tank. Risk of Unsafe Working air is not available until the Operation. Serious compressor has raised the air tank damage may result if the following pressure above that required at the air break-in instructions are not...
  • Page 14: Customer Responsibilities

    Risk of unsafe Risk of Flying Objects. Pull operation. Compressed air from the unit may the regulator knob out and turn contain water condensation counter-clockwise to set the outlet oil mist. Do not spray unfiltered pressure to zero when removing at an item that could be damaged hose or accessories to prevent...
  • Page 15: To Check Safety Valve

    To Drain Tank Risk of Unsafe Operation. Unit Risk of unsafe cycles automatically when power operation. Air tanks is on. When servicing, you may contain high pressure air. Keep face be exposed to voltage sources, and other body parts away from compressed air, or moving parts.
  • Page 16: Hot Surfaces

    Air Filter Inspection Remove the air filter and make sure it is clean. Replacement IMPORTANT: Do not operate the Hot surfaces. compressor with the air filter removed. Risk of burn. If dirty, rinse air filter with warm Compres-sor heads are exposed water and squeeze dry.
  • Page 17 Set the Auto/Off lever to "Off" and Outlet unplug unit. Remove the outlet pressure gauge and quick connect (if equipped) from the regulator. Unscrew the check valve (turn counterclockwise) using a 7/8" open end wrench. NOTE the ori- entation for reassembly. Using a screwdriver, carefully push...
  • Page 18 Before you store the air compressor, Risk of Bursting. make sure you do the following: Water will Review the Maintenance section condense in the air tank. If not on the preceding pages and per- drained, water will corrode form scheduled maintenance weaken the air tank causing a risk...
  • Page 19 Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 20 CORRECTION PROBLEM CAUSE If there is an excessive Pressure It is normal for "some" amount of pressure drop when reading pressure drop to occur. the accessory is used, adjust the regulated the regulator following pressure _nstructions in the Description gauge drops when an of Operation paragraph...
  • Page 21 PROBLEM CAUSE CORRECTION Let motor cool off and Motor will not Motor overload protection overload switch will run. switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically pressure switch "cut-in" when tank pressure drops below "cut-in" pressure of pressure.
  • Page 22 Air Compressor Model Number 919.167784 PARTS SHOWN FOR REFERENCE ONLY AIR COMPRESSOR - MODEL NUMBER 919.167784 8/08TS N015838 22- ENG N015838...
  • Page 23: Assembly

    Air Compressor Model Number 919.167784 ITEM PART DESCRIPTION SSF-990 Screw ACG-18 Saddle Mount Cup Z-D21929 Gauge 5130039-00 Sleeve A 17357 Pressure Switch SUDL-9-1 Screw 1000001958 Nipple D26615 Power Cord (14ga) AC-0609 Handle D21172 Screw A19122 Tube SSP-7811 SSP-7813 A19712 Check Valve TIA4200 Safety Valve AC-0774...
  • Page 24 Air Compressor Model Number 919.167784 PARTS SHOWN FOR REFERENCE ONLY I O3 1_01 24- ENG N015838...
  • Page 25 Air Compressor Model Number 919.167784 ITEM PART DESCRIPTION 101 Z-D27263 Motor {102 D24596 Bolt 103 D24958 Connecting Rod Kit (incl. !11, 113,115,116) 104 D24597 Outer Eccentric 106 ACG-22 _107 39124607 Screw 109 A02743 Connecting Rod Kit (incl. 113,115) 110 K-0648 Comp Ring Kit (Incl.
  • Page 26: Importantes Instrucciones

    GARANT|A ............CUADRO DE ESPEClFICACIONES ........DEFINIClONES DE NORMAS DE SEGURIDAD ......IMPORTANTES INSTRUCCIONES DE SEGURIDAD ....27-33 GLOSARIO ............CICLO DE SERVICIO ..........ACCESORIOS ........... ENSAMBLADO ........... INSTALACION ........... 4-35 OPERACION ........... 36-39 MANTENIMIENTO ..........39-40 SERVICIOS Y REGULACIONES ........41-42 ALMACENAJE ............
  • Page 27 Modelo N° 919.167784 Diametro interior 60,3 mm (2,375 pulg.) Carrera Presi6n de alto - 13,7 mm (0,54 pulg.) Presion de mugir - 36,8 mm (1,45 pulg.) Voltaje-corriente manofksica Circuito minimo requerido Tipo de fusible Acci6n retardada Capacidad de aire en el tanque 94,6 litros (25 Galones) Presi6n de corte de entrada 120 psig...
  • Page 28 RIESGO DE EXPLOSION O INCENDIO _,Qu_ puede suceder? Cbmo evitarlo Es normal que los contactos electricos Opere siempre el compresor en un dentro del motor y el interruptor de area bien ventilada libre de materiales presi6n produzcan chispas. combustibles, gasolina o vapores de solventes.
  • Page 29 f_v.,l=lVi=l--il=l_[=ir_,l RIESGO DE EXPLOSI6N Tanque de aire" El tanque de aire de su compresor de aire esta diseSado y puede tener c6digo UM (para unidades con tanques de aire de m_.s de 152 mm i6 pulgadas) diametro) segt)n las normas de la ASME, Seccion VIII, Div.
  • Page 30 _!V-'l=lvJ_-'tl=O[Hf-'_ RIESGO DE DESCARGA ELECTRICA &Qu_ puede suceder? Cbmo evitarlo Su compresor de aire funciona Nunca haga funcionar el compresor con electricidad. Como cualquier aire libre cuando esta Iloviendo o en condiciones de humedad. otro mecanismo que funciona con electricidad, si no se Io utiliza Nunca haga funcionar el compresor correctamente puede provocar...
  • Page 31 _Fv-'!=_'==l-'tt=l_[_]r-'l RIESGO DE SUPERFICIES CALIENTES &Qud puede suceder? Cbmo evitarlo Tocar metal expuesto como el cabezal Nunca toque ninguna parte met&lica del compresor, el cabezal del motor, el expuesta del compresor durante escape del motor, o los tubos de salida o inmediatamente despues de su puede provocar quemaduras graves.
  • Page 32 F!Y:I _}vJ :1:t / :1_, [ o]r:1 RIESGO DE OPERACION INSEGURA &Qu6 puede suceder? Cbmo evitarlo La operacion insegura de su compresor Revise y comprenda todas las de aire podrfa producir lesiones graves instrucciones y advertencias de este o la muerte, a usted mismo o a otras manual.
  • Page 33 RIESGO POR RUIDOS i.,Qu_ puede suceder?. Cbmo evitarlo • En cleterminadascondiciones y seg_n el • Utilice siempre equipo de seguridad perJodo de uso, el ruido provocado por certificado:protecci6n auditiva ANSI este producto puede originarp_rdida de $12.6 ($3.19). audici6n. CONSERVE ESTAS INSTRUCClONES PAPA FUTURAS CONSULTAS...
  • Page 34: Instrucciones Para Conectar A Tierra

    Esta unidad es suficiente para abastecer de energia electrica a los siguientes accesorios. Estos se encuentran disponibles a traves del catalogo para herramientas electricas y man- uales, en cualquiera de los comercios que mantiene la Ifnea completa de SEARS. Accesorios Refierase al grafico de seleccion ubicado sobre la unidad, para elegir el tipo de her- •...
  • Page 35 Si las instrucciones de conexion a tierra Proteccibn del voltaje y del no fueran completamente compren- circuito didas, o si se estuviera ante la duda Acerca del voltaje y la minima cantidad de acerca de que el compresor estuviese circuitos requeridos, refierase al cuadro de adecuadamente conectado a tierra, especificaciones.
  • Page 36 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 37 Bomba de compresion del aire (no Procedimiento para el asentamiento mostrada): Comprime el aire dentro del Riesgo de Operaci6n tanque. El aire de trabajo no se encuentra Insegura. Si las disponible hasta que el compresor haya siguientes instrucciones no fuesen seguidas alcanzado a Ilenar el tanque hasta un nivel estrictamente, podran ocurrir serios daSos.
  • Page 38 Riesgo de Objetos Riesgo de Arrojados por el operacibn insegura. aire. Para evitar un latigazo, cuando se El aire comprimido de la unidad puede le saquen accesorios a la manguera o contener condensacibn de agua y se saque la manguera misma, primero emanacibn de aceite.
  • Page 39: Responsabilidades Del Cliente

    Responsabilidades del cliente Antes Diariamente Cada Anualmente de cada o luego de cada uso horas Verifique la valvula de seguridad Drenaje del tanque Filtro de aire Valvulas de entrada y escape de la bomba del compresor de aire 1- M_s frecuente en condiciones polvorientas o hemedas.
  • Page 40 NOTA: Todos los sistemas de aire com- Filtro de Aire - Inspeccibn primido generan condensaci6n que se reemplazo acumula en cualquier punto de drenaje (por ejemplo, tanques, filtro, posenfriadores, f!V:1 Blvj_1 :_1 ii_1 _, [ i.]r±l Su,.pe_icies. secadores). Esta condensaci6n contiene callemes.
  • Page 41 TODO TIPO DE MANTENIMIENTO Y Tubo de REPARACIONES NO MENCIONADOS _" s alida EN ESTE MANUAL, DEBERAN SER EFECTUADOS POR PERSONAL TI=CNICO ESPECIALIZADO. Riesgo de Operacibn Insegura. La unidad arranca automdticamente cuando esta enchufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire...
  • Page 42: Para Reemplazar El Regulador

    NOTA" La flecha indica el sentido del flujo Para reemplazar el regulador del aire. AsegQrese que este apuntando a Libere toda la presion del aire del la direccion en la que fluye el aire. tanque. Vea Drenaje del tanque en la seccion Mantenimiento.
  • Page 43 Drene el agua del tanque de aire Antes de guardar su compresor de aire, abriendo la vaivula de drenaje ubicada asegt]rese de hacer Io siguiente: en el fondo del tanque. Revise la secci6n Mantenimiento de las paginas precedentes y ejecute el Riesgo de Explosibn.
  • Page 44 nr,_v,1eivi:t:tUUl_l_[_dr:_ Riesgo de Operacion Insegura. La unidad arranca autom&ticamente cuando esta enchufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles. Antes de intentar hacer reparaciones, desconectar el compresor del tomacorriente, drenar la presion de aire del tanque y esperar a que el compresor se enfrie.
  • Page 45 PROBLEMA CAUSEA CORRECCION La lectura de la Si hubiese una caida excesiva Es normal que ocurra alg6n presibn sobre descenso en la presion. de presion durante el uso del un manbmetro accesorio, ajuste el regulador de acuerdo a las instrucciones (si viene equipado con de la secci6n Operacion.
  • Page 46 PROBLEMA CAUSEA CORRECCION El motor no El interruptor de protecci6n des Deje enfriar el motor y el funciona, obrecarga del motor se ha interruptor de sobrecarga se abierto, reajustara automaticamente. La presi6n del tanque excede la E! motor arrancarA presi6n de "corte m&ximo" del automaticamente cuando interruptor...
  • Page 47: Installation

    Congratulations on making a smart Felicitaciones por hacer una compra purchase. Your new Craftsman ® product inteligente. Su nueva unidad Craftsman ® esta is designed and manufactured for years disefiada y fabricada para afios de operaci6n of dependable operation. But like all confiable;...
  • Page 48: Maintenance

    Your Home For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances...