KitchenAid JUD248CCRS00 Manual page 8

Double refrigerator drawers
Table of Contents

Advertisement

Available languages

Available languages

When
Moving Your Refrigerator
Drawers:
Your refrigerator drawers are heavy. When moving the
appliance for service, be sure to cover the floor with
cardboard or hardboard to avoid floor damage. Always pull
the appliance straight out when moving it. Do not wiggle or
"walk" the appliance when trying to move it, as floor
damage could occur.
Clean Before Using
Connect
to Refrigerator
1. Attach the copper tube to the valve inlet using a compression
nut and sleeve as shown. Tighten the compression
nut. Do
not overtighten. Use the tube clamp on the back of the
refrigerator to secure the tubing to the refrigerator as shown.
This will help avoid damage to the tubing when the
refrigerator is pushed back against the wall.
2. Turn shutoff valve ON.
3. Check for leaks. Tighten any connections (including
connections
at the valve) or nuts that leak.
After you remove all of the package materials, clean the inside of
your refrigerator drawers before using them. See the cleaning
instructions
in the Use & Care Guide.
Connect to Water Line
1. Unplug refrigerator or disconnect
power.
2. Turn OFF main water supply. Turn ON nearest faucet long
enough to clear line of water.
3. Locate a 1/2"to 11/4"(1.25 cm to 3.18 cm) vertical cold water
pipe near the refrigerator.
IMPORTANT:
4.
5.
Make sure it is a cold water pipe.
Horizontal pipe will work, but drill on the top side of the
pipe, not the bottom. This will help keep water away from
the drill and normal sediment from collecting
in the valve.
Determine the length of copper tubing you need. Measure
from the connection on the lower left rear of refrigerator to the
water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use V4"
(6.35 mm) O.D. (outside diameter) copper tubing. Be sure
both ends of copper tubing are cut square.
Using a grounded drill, drill a V4" hole in the cold water pipe
you have selected.
A. Cold waterpipe
B. Pipe clamp
C. Copper tubing
D. Compression
nut
E. Compression
sleeve
F. Shutoff
valve
G. Packing
nut
6. Fasten the shutoff valve to the cold water pipe with the pipe
clamp. Be sure the outlet end is solidly in the V4" drilled hole
in the water pipe and that the washer is under the pipe clamp.
Tighten the packing nut. Tighten the pipe clamp screws
slowly and evenly so washer makes a watertight seal. Do not
overtighten
or you may crush the copper tubing.
7. Slip the compression
sleeve and compression
nut on the
copper tubing as shown. Insert the end of the tubing into the
outlet end squarely as far as it will go. Screw compression
nut
onto outlet end with adjustable wrench. Do not overtighten.
8. Place the free end of the tubing in a container or sink, and
turn ON the main water supply. Flush the tubing until water is
clear. Turn OFF the shutoff valve on the water pipe. Coil the
copper tubing.
Q
.......................
'_ C
A. Plug
B. Compression
nut
C. Pex tubing
4. The ice maker is equipped with a built-in water strainer. If
your water conditions require a second water strainer, install
it in the V4" (6.35 mm) water line at either tube connection.
Obtain a water strainer from your nearest appliance dealer.
5. Plug in refrigerator or reconnect power.
l:':in.al
1. Place top of cardboard carton or plywood under the
appliance. Remove dolly.
2. Do not remove film or cover.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
3. Plug into a grounded 3 prong outlet.
4. Move the refrigerator drawers straight back and evenly in
front of the opening.
8