Installation
Instructions
(cont'd)
Installation
Checklist
BEFORE
LIGHTING
THE
PILOT:
•
Check the gas lines for leaks.
a. Use a soapy water solution.
DO NOT
test for gas leaks
using a match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
fittings.
c. Cheo<
for bubbling
soap. This means
you have a leak.
Turn "OFF" gas and make the necessary repairs.
d. Recheck for leaks.
e. Rinse offsoapy
solution and wipe dry.
•
Is the new temperature÷pressure
relief valve properly installed
and piped to an adequate
drain? See "Temperature-Pressure
Relief Valve" section.
• Are the cold and hot water lines connected
to the water
heater correctly? See "Water Piping" instructions
in the
"Installation Instructions" section.
• Is the water heater completely filled with water? See "Filling"
"nstructions in the Installation Instructions" section.
•
Will
a water
leak
damage
anything?
See the "Facts
to
Consider About the Location" secnon.
•
Is there proper
clearance between
the water heater and any-
thing that might catch fire? See the
Facts to Consider About
the Location" section.
• Do you have adequate ventilation so that the water heater
will op,erate properly? See Combustion Air and Vennlanon"
in the Installation Instructions
section.
• Is the draft hood vent piping properly secured? See "Venting"
nstruct'ons in the Installation Instruct ons' sect on.
• Is there proper clearance between the vent pipe and anything
that m'ght catch on fire? See "Venting
instructions in the
Installat on Instrucuons
section.
•
ls the vent pipe properly
sloped and does the vent terminate
outdoors?
See "Venting"
"nstruct'ons
in the 'Installation
Instructions"
section.
• Do you need to call your gas company to check the gas pipe
and its hookup?" section.
HOT
GAS
SUPPLY
SHUTOFF
VALVE
---_
TEE
2
_
--
I i
DRIP
LEG_
(Sediment
trap)
CAPri
I
DRAIN
VALVE
/
VENT
PIPE TO
OUTDOORS
OR CHIMNEY
SHUTOFF
VALVE
t
COLD
UNION
DRAFTHOOD
/TEMPERATURE-
PRESSURE
RELIEF VALVE
--
DISCHARGE
PIPE
(Do not cap or plug)
6" AIR GAP
FLOOR DRAIN
_
_I_O_TAT_
GAS PRESSURE
IN WC
I
I
I
MODEL RATING PLATE
16