Installation Checklist - Kenmore 153.336152 Owner's Manual

Gas water heater
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Installation
Checklist
BEFORE
LIGHTING
THE
PILOT:
Check the gas lines for leaks.
a. Use a soapy water solution.
DO NOT
test for gas leaks
using a match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
fittings.
c. Cheo<
for bubbling
soap. This means
you have a leak.
Turn "OFF" gas and make the necessary repairs.
d. Recheck for leaks.
e. Rinse offsoapy
solution and wipe dry.
Is the new temperature÷pressure
relief valve properly installed
and piped to an adequate
drain? See "Temperature-Pressure
Relief Valve" section.
• Are the cold and hot water lines connected
to the water
heater correctly? See "Water Piping" instructions
in the
"Installation Instructions" section.
• Is the water heater completely filled with water? See "Filling"
"nstructions in the Installation Instructions" section.
Will
a water
leak
damage
anything?
See the "Facts
to
Consider About the Location" secnon.
Is there proper
clearance between
the water heater and any-
thing that might catch fire? See the
Facts to Consider About
the Location" section.
• Do you have adequate ventilation so that the water heater
will op,erate properly? See Combustion Air and Vennlanon"
in the Installation Instructions
section.
• Is the draft hood vent piping properly secured? See "Venting"
nstruct'ons in the Installation Instruct ons' sect on.
• Is there proper clearance between the vent pipe and anything
that m'ght catch on fire? See "Venting
instructions in the
Installat on Instrucuons
section.
ls the vent pipe properly
sloped and does the vent terminate
outdoors?
See "Venting"
"nstruct'ons
in the 'Installation
Instructions"
section.
• Do you need to call your gas company to check the gas pipe
and its hookup?" section.
HOT
GAS
SUPPLY
SHUTOFF
VALVE
---_
TEE
2
_
--
I i
DRIP
LEG_
(Sediment
trap)
CAPri
I
DRAIN
VALVE
/
VENT
PIPE TO
OUTDOORS
OR CHIMNEY
SHUTOFF
VALVE
t
COLD
UNION
DRAFTHOOD
/TEMPERATURE-
PRESSURE
RELIEF VALVE
--
DISCHARGE
PIPE
(Do not cap or plug)
6" AIR GAP
FLOOR DRAIN
_
_I_O_TAT_
GAS PRESSURE
IN WC
I
I
I
MODEL RATING PLATE
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents