Thermostat And Gas Supply Check - Kenmore POWER MISER 153.35862 Owner's Manual

Power vent gas water heater
Table of Contents

Advertisement

Troubleshooting
Guide (cont'd)
A WARNING
Thistroubleshooting
guidehasbeensupplied for usebyquali- J
fled service personnel whohavea completeunderstanding of
bethelectricity andgas.
A CAUTION
Label all wiling before disconnecting any wiring; to ensure
correct reconnection. Failure to follow this instruction I
could cause improper and possible dangerous operation,
resulting in DEATH,
SERIOUS
BODILY
INJURY, OR
PROPERTY DAMAGE.
THERMOSTAT
AND
GAS SUPPLY
CHECK
No
i
I
?
I Turn "ON" gas supply.
Is gas being
thermostat?
supplied
to the
Light
Pilot.
(See
Lightlng[
Instructions in manual
or attached I-4,
to water heater.)
I Pilot won't light.
!
Check thermocouple.
Bad
I Replace thermocouple.
I [Pil° ligh .
I
Good
[ Turn gas cock knob to
_ON".
Replacethermostat.
I
r
I
I
Replace thermostat.
No
Is pilot lit?
I
-J
yes
Is gas cock knob turned "ON"?
[
q
I
I
Yes
Is thermostat calling for heat? Run [
(hot) water from heater and turn [
adjustment
knob higher.
Check ]
using a manometer
at thermostat
pressure tap.
No
.............
J
Yes
Call gas company
to increase gas
pressure.
_ ................
No
Is there a minimum gas pressure 3_7'
W.C. for natural gas or 8" W.C. for
propane (L.P,) gas?
'
I
............
.J
Yes
GO TO ELECTRICAL
SYSTEM
CHECK SECTION
32

Advertisement