DataNET Troubleshooting Guide,
Configuration
Parameter Errors
Device ID
Broadcast Status
Information
2000592-001
Continued
The device may have an invalid or duplicate IP address, Subnet mask or
iproute. Each ANCB must have a unique IP address. Verify the
configuration parameters by connecting a PC serial port to the
Configuration Port, Logging in and typing config display.
local> config display
Config:
Device
address ip
netmask
address ethernet
iproute
time server ip
port1
port2
The ANCB/DN device id is automatically assigned and is not user
configurable as it is on the DataNET Hub. Th ANCB/DN device ID is
automatically set to the board IP address at power up or reset. :
The Advance Network device periodically broadcast their status for
diagnostic and network routing purposes.
ANCB_DN
172.16.9.239
255.255.0.0
00.c0.c9.00.d2.3b
0.0.0.0
0.0.0.0
DataNET Copper
DataNET Copper
Troubleshooting • 53