HP StorageWorks 2/8q Fibre Channel Switch First Edition (November 2004) Part Number: A7540-96010 This manual describes the features of, and installation procedures for, the HP StorageWorks 2/8q Fibre Channel Switch. Sections include: Introduction—provides an overview of LEDs, connections, and user controls.
Page 2
Hewlett-Packard. The information contained in this document is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services.
The following MSA1000 SAN Kit and 2/8q FC Switch documents are on the MSA1000 Small Business SAN documentation CD: HP StorageWorks Modular Smart Array 1000 Small Business SAN Kit Installation Instructions (also printed) HP StorageWorks 2/8q Fibre Channel Switch Management User Guide...
Text in a tip provides additional help to readers by providing nonessential or optional techniques, procedures, or shortcuts. Note: Text set off in this manner presents commentary, sidelights, or interesting points of information. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Only one rack component is extended at any time. A rack may become unstable if more than one rack component is extended for any reason. Getting help If you still have a question after reading this guide, contact an HP Authorized Service Provider or access our web site: http://www.hp.com. Note: HP call centers use product and serial numbers to validate warranty entitlement.
Operating system type and revision level Detailed, specific questions HP storage web site The HP web site has the latest information on this product, as well as the latest drivers. Access storage at: http://www.hp.com/country/us/eng/prodserv/storage.html. From this web site, select the appropriate product or solution.
Page 12
About this Guide HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
The Input Power LED indicates the voltage status at the switch logic circuitry. During normal operation, this LED illuminates to indicate that the switch logic circuitry is receiving the proper DC voltages. When the switch is in maintenance mode, this LED is extinguished. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
The Ethernet port has two LEDs that provide activity and status information. (Figure The Activity LED illuminates when data is being transmitted or received. The Link Status LED illuminates continuously when an Ethernet connection has been established. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
LED illuminated. The Heartbeat LED illuminates continuously while the switch is in maintenance mode. Exiting maintenance mode To exit maintenance mode and return to normal operation, momentarily press and release the Maintenance button to reset the switch. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
When extending credits, the Activity LED for a donor port will reflect the traffic of the recipient port. See “Distance” on page 24 for more information about extended credits and donor ports. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
An F_Port supports a single public device. If the device is a single device on a loop, the GL_Port will attempt to configure first as an F_Port, then if that fails, as an FL_Port. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
1 and 2, the Fibre Alliance Management Information Base (FA-MIB) version 4.0, and the Fabric Element Management Information Base (FE-MIB) RFC 2837. Traps can be formatted using SNMP version 1 or 2. Refer to the HP StorageWorks 2/8q Fibre Channel Switch SNMP Reference Guide for more information.
A zoning database is maintained on each switch consisting of all inactive zone sets, the active zone set, all zones, aliases, and their membership. Refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for more information about zoning.
Soft zones can overlap; that is, a port can be a member of more than one soft zone. Membership can be defined by Fibre Channel address, domain ID and port number, or worldwide name. Soft zoning supports FL_Ports and F_Ports. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Latency is a measure of how fast a frame travels from one port to another. Factors that affect latency include transmission rate and the source/destination port relationship. 2 Gbps to 2 Gbps transmissions have a latency factor < 0.4 µsec. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
6 logins or sessions for Switch Manager logins and Telnet logins. Additional logins are refused. “Management System Requirements” on page 63 for connection information and refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for information about using these management tools. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
59 for a detailed list): Table 3: Environmental requirements Item Requirement Power requirements 1 Amp at 120 VAC or 0.5 Amp at 240 VAC Operating temperature range ° °C (41°-104°F) Operating relative humidity 15%-80%, non-condensing HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Power cable (approved for use in the United States) Mounting adapter brackets Screws for the mounting adapter brackets (6) Rubber feet (4) Small Form Factor Pluggable (SFP) transceivers (4) Figure 5: Switch carton contents HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Figure 6: Using the rack template Note: If the holes in the rack are round instead of square, remove the standard pins from the rails and replace them with the round-hole pins provided with the rail kit. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Extend the other end of the rail toward the inside front of the rack until the pins extend through the marked holes and the locking latch engages. (Figure Figure 7: Attaching the right rail to the rack - rear view HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Use four of the provided screws to attach the brackets to the switch. Figure 9: Attaching the mounting adapter brackets to the switch HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
7. Secure the switch to the back of the rack by inserting and tightening the 2 remaining provided screws through the bracket flanges. (Figure Figure 11: Securing the switch flanges to the rear of the rack HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
The transceiver fits only one way in the port. If the transceiver does not install under gentle pressure, pull it out of the port, turn it over, and re-insert it. Figure 13: Installing an SFP transceiver HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
POST was successful, and you can continue with the installation process. Any other blink pattern indicates that an error has occurred. See “Heartbeat LED blink patterns” on page 42 for more information about error blink patterns. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
1. Close all programs currently running, and then insert the Small Business SAN Software CD into the server or management workstation CD-ROM drive. The CD auto-mounts, and executes an installation script. If the CD does not auto-mount, mount the CD and execute the HP Small Business Linux Wizard script from the directory. (install_smb.sh) /linux 2.
“Management System Requirements” on page 63 for information about connecting a workstation to the switch and refer to “Backing up a switch configuration” in the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide, for procedural details. Powering down the switch Simply unplugging the switch from the power source does not allow the switch to complete executing tasks and could lead to flash memory corruption.
MSA1000 web site at www.hp.com/go/msa1000. See“Management System Requirements” on page 63 for information about connecting a workstation to the switch and refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for detailed information about Switch Manager and the CLI. Note: You can load and activate new firmware on an operating switch without disrupting data traffic or having to re-initialize attached devices.
Page 39
4. Enter the password for your account name. 331 Password required for johndoe. Password:****** 230 User johndoe logged in. The firmware is downloaded from the remote host to the switch, is installed, and is activated. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
LEDs. Diagnostic information is also available through the Switch Manager and CLI event logs and error displays. This section describes the following diagnostics and tasks: POST diagnostics, page 42 Chassis diagnostics, page 46 Maintenance mode options, page 47 HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Whether the problem is critical or not, contact your HP Authorized Maintenance Provider. If there are no errors, the Heartbeat LED blinks at a steady rate of once per second. If a critical error occurs, the Heartbeat LED shows an error blink pattern and the System Fault LED will illuminate.
A system error blink pattern is 3 blinks followed by a two second pause. The 3-blink error pattern indicates that a POST failure or a system error has left the switch inoperable. If a system error occurs, contact your HP Authorized Maintenance provider. Momentarily press and release the Maintenance button to reset the switch.
Figure 15: Logged-In LED location and blinking patterns See the following sections for information about identifying the cause of the error, and refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for information about correcting the error condition.
Decode errors Login / Logout errors Loss-of-signal errors Port threshold alarm monitoring is disabled by default. Refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for information about managing port threshold alarms. If the count for any of these errors exceeds the rising trigger for three consecutive sample windows, the switch generates an alarm and disables the affected port, changing its operational state to “down.”...
— No - Continue. 2. Inspect the AC power source. Is the power source delivering the proper voltage? — Yes - Continue. — No - Make necessary repairs. If the condition remains, contact your HP Authorized Maintenance Provider. System Fault LED is illuminated The System Fault LED illuminates to indicate that the switch logic circuitry is overheating or that a POST error has occurred.
This option restores the switch configuration parameters to the factory defaults and deletes all other configurations from the switch. User account and zoning information is retained. Refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for the default values.
Maintenance menu – Update Boot Loader This option updates the system boot loader. This is the program that loads the Linux kernel into memory. Use this option only at the direction of your HP Authorized Maintenance Provider. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 Or, call (281) 514-3333 To identify this product, refer to the Part, Series, or Model number found on the product. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Regulatory Compliance Notices Japanese Notice Japanese Power Cord Notice Korean notices Class A equipment HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
The SFP Module contains a laser diode of either gallium aluminum arsenide (GaALAs) emitting in the wavelength range of 770-860 nm, or indium gallium arsenide phosphide (InGaAsP) emitting in the wavelength range of 1270-1355 nm. All HP systems equipped with a laser device comply with safety standards, including International Electrotechnical Commission (IEC) 825.
Vanadium Pentoxide, batteries. There is a danger of explosion and risk of personal injury if the array is incorrectly replaced or mistreated. Replace only with the HP spare designated for this product. For more information about battery replacement or proper disposal, contact your HP Authorized Reseller or your HP Authorized Service Provider.
Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the equipment suggested for proper grounding, either have an HP Authorized Reseller install the part or discharge any potential static by touching a piece of sheet metal immediately before touching the component or the device.
RJ-45 connector; 10/100 BASE-T cable Switch agent Allows a network management station to obtain configuration values, traffic information, and failure data pertaining to the Fibre Channels using SNMP through the Ethernet interface. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
CISPR 22, Class A EN 55022, Class A Voltage Fluctuations EN 61000-3-3 Harmonics EN 61000-3-2 Immunity EN 55024:1998 Marking FCC Part 15 (United States) (United States) cUL (Canada) cTUV (Canada) TUV Europe (Germany) VCCI HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
CD-ROM drive, RS-232 serial port, RJ-45 Ethernet port Internet browser Windows: Microsoft® Internet Explorer®, version 5.5 or greater Linux: Netscape Navigator, version 6.2 or greater or Mozilla , version 1.0.2 or greater with Personal Security Manager HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
With this type of connection, you can access the Command Line Interface. Table 12: Ethernet and serial Cable Pin Configurations Indirect Ethernet connection Direct Ethernet connection Serial connection straight cable cross-over cable null modem cable HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
3. Open a Telnet session by entering the following command with the switch IP address (Default IP address: 10.0.0.1): telnet 10.0.0.1 4. Log in to the switch. The default account name and password are ( admin password switch login: admin password: ******** HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
3. Log in to the switch. If fabric security is disabled, account names and passwords are not enforced. Refer to the command in the CLI portion of the HP StorageWorks 2/8q FC Switch Set Setup Management User Guide for information about setting fabric security. The default account name and password are (admin, password).
LEDs indirect connection marking Link Status LED shock port vibration port location classes of service European Union notice configuration backing up file F_Port file system error 16, 43, fabric remove HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Page 68
27, non-critical error HyperTerminal application non-disruptive activation null modem F/F DB9 cable immunity inband management over temperature HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Page 69
14, rack stability location of symbols on equipment shock web sites Simple Network Management Protocol HP storage description workstation 63, 64, HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
Page 70