HP STORAGEWORKS A7540-96010 Installation Manual
HP STORAGEWORKS A7540-96010 Installation Manual

HP STORAGEWORKS A7540-96010 Installation Manual

2/8q fibre channel switch
Table of Contents

Advertisement

Quick Links

HP StorageWorks
2/8q Fibre Channel Switch
First Edition (November 2004)
Part Number: A7540-96010
This manual describes the features of, and installation procedures for, the HP StorageWorks 2/8q Fibre
Channel Switch.
Sections include:
Introduction—provides an overview of LEDs, connections, and user controls.
Planning—describes the factors to consider when planning a fabric.
Installing—explains how to install and configure the switch.
Troubleshooting—describes the diagnostic methods and troubleshooting procedures.
Regulatory Compliance
Electrostatic
Discharge—discusses static electricity concerns.
Specifications
—ists the switch specifications.
Notices—includes notices about the switch.
Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for HP STORAGEWORKS A7540-96010

  • Page 1 HP StorageWorks 2/8q Fibre Channel Switch First Edition (November 2004) Part Number: A7540-96010 This manual describes the features of, and installation procedures for, the HP StorageWorks 2/8q Fibre Channel Switch. Sections include: Introduction—provides an overview of LEDs, connections, and user controls.
  • Page 2 Hewlett-Packard. The information contained in this document is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services.
  • Page 3: Table Of Contents

    HP installation and configuration assistance ........
  • Page 4 ... 48 Maintenance menu – Copy Log Files ....48 HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 5 Serial connection information ............66 HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 6 12 Ethernet and serial Cable Pin Configurations ..........64 HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 7: About This Guide

    The following MSA1000 SAN Kit and 2/8q FC Switch documents are on the MSA1000 Small Business SAN documentation CD: HP StorageWorks Modular Smart Array 1000 Small Business SAN Kit Installation Instructions (also printed) HP StorageWorks 2/8q Fibre Channel Switch Management User Guide...
  • Page 8: Document Conventions

    Text in a tip provides additional help to readers by providing nonessential or optional techniques, procedures, or shortcuts. Note: Text set off in this manner presents commentary, sidelights, or interesting points of information. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 9: Equipment Symbols

    WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 10: Rack Stability

    Only one rack component is extended at any time. A rack may become unstable if more than one rack component is extended for any reason. Getting help If you still have a question after reading this guide, contact an HP Authorized Service Provider or access our web site: http://www.hp.com. Note: HP call centers use product and serial numbers to validate warranty entitlement.
  • Page 11: Hp Technical Support

    Operating system type and revision level Detailed, specific questions HP storage web site The HP web site has the latest information on this product, as well as the latest drivers. Access storage at: http://www.hp.com/country/us/eng/prodserv/storage.html. From this web site, select the appropriate product or solution.
  • Page 12 About this Guide HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 13: Introduction

    Switch chassis features Power supply, page 14 Serial port, page 14 Chassis LEDs, page 14 Ethernet port, page 15 Maintenance button, page 16 Fibre Channel ports and LEDs, page 17 Figure 1: Chassis features HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 14: Power Supply

    The Input Power LED indicates the voltage status at the switch logic circuitry. During normal operation, this LED illuminates to indicate that the switch logic circuitry is receiving the proper DC voltages. When the switch is in maintenance mode, this LED is extinguished. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 15: Heartbeat Led (Green)

    The Ethernet port has two LEDs that provide activity and status information. (Figure The Activity LED illuminates when data is being transmitted or received. The Link Status LED illuminates continuously when an Ethernet connection has been established. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 16: Maintenance Button

    LED illuminated. The Heartbeat LED illuminates continuously while the switch is in maintenance mode. Exiting maintenance mode To exit maintenance mode and return to normal operation, momentarily press and release the Maintenance button to reset the switch. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 17: Fibre Channel Ports And Leds

    When extending credits, the Activity LED for a donor port will reflect the traffic of the recipient port. See “Distance” on page 24 for more information about extended credits and donor ports. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 18: Sfp Transceivers

    An F_Port supports a single public device. If the device is a single device on a loop, the GL_Port will attempt to configure first as an F_Port, then if that fails, as an FL_Port. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 19: Switch Management

    1 and 2, the Fibre Alliance Management Information Base (FA-MIB) version 4.0, and the Fabric Element Management Information Base (FE-MIB) RFC 2837. Traps can be formatted using SNMP version 1 or 2. Refer to the HP StorageWorks 2/8q Fibre Channel Switch SNMP Reference Guide for more information.
  • Page 20 Introduction HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 21: Planning

    Planning Consider the following when planning a fabric: Devices, page 22 Device access, page 22 Performance, page 24 Fabric security, page 25 Fabric management, page 25 HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 22: Devices

    A zoning database is maintained on each switch consisting of all inactive zone sets, the active zone set, all zones, aliases, and their membership. Refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for more information about zoning.
  • Page 23: Hard Zones (Access Control Lists)

    Soft zones can overlap; that is, a port can be a member of more than one soft zone. Membership can be defined by Fibre Channel address, domain ID and port number, or worldwide name. Soft zoning supports FL_Ports and F_Ports. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 24: Performance

    Latency is a measure of how fast a frame travels from one port to another. Factors that affect latency include transmission rate and the source/destination port relationship. 2 Gbps to 2 Gbps transmissions have a latency factor < 0.4 µsec. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 25: Fabric Security

    6 logins or sessions for Switch Manager logins and Telnet logins. Additional logins are refused. “Management System Requirements” on page 63 for connection information and refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for information about using these management tools. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 26 Planning HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 27: Installing

    59 for a detailed list): Table 3: Environmental requirements Item Requirement Power requirements 1 Amp at 120 VAC or 0.5 Amp at 240 VAC Operating temperature range ° °C (41°-104°F) Operating relative humidity 15%-80%, non-condensing HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 28: Installing And Initially Configuring The Switch

    Power cable (approved for use in the United States) Mounting adapter brackets Screws for the mounting adapter brackets (6) Rubber feet (4) Small Form Factor Pluggable (SFP) transceivers (4) Figure 5: Switch carton contents HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 29: Mount The Switch

    Figure 6: Using the rack template Note: If the holes in the rack are round instead of square, remove the standard pins from the rails and replace them with the round-hole pins provided with the rail kit. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 30: Attaching The Right Rail To The Rack - Rear View

    Extend the other end of the rail toward the inside front of the rack until the pins extend through the marked holes and the locking latch engages. (Figure Figure 7: Attaching the right rail to the rack - rear view HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 31: Moving The Rail Retaining Bracket On The Right Rail - Rear View

    Use four of the provided screws to attach the brackets to the switch. Figure 9: Attaching the mounting adapter brackets to the switch HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 32: Placing The Switch On The Rails - Rear View

    7. Secure the switch to the back of the rack by inserting and tightening the 2 remaining provided screws through the bracket flanges. (Figure Figure 11: Securing the switch flanges to the rear of the rack HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 33: Securing The Rail Retaining Brackets To The Switch - Front View

    (Figure Figure 12: Securing the rail retaining brackets to the switch - front view HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 34: Install Sfp Transceivers

    The transceiver fits only one way in the port. If the transceiver does not install under gentle pressure, pull it out of the port, turn it over, and re-insert it. Figure 13: Installing an SFP transceiver HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 35: Connect The Cables

    POST was successful, and you can continue with the installation process. Any other blink pattern indicates that an error has occurred. See “Heartbeat LED blink patterns” on page 42 for more information about error blink patterns. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 36: Configure The Switch

    1. Close all programs currently running, and then insert the Small Business SAN Software CD into the server or management workstation CD-ROM drive. The CD auto-mounts, and executes an installation script. If the CD does not auto-mount, mount the CD and execute the HP Small Business Linux Wizard script from the directory. (install_smb.sh) /linux 2.
  • Page 37: Backing Up The Switch Configuration

    “Management System Requirements” on page 63 for information about connecting a workstation to the switch and refer to “Backing up a switch configuration” in the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide, for procedural details. Powering down the switch Simply unplugging the switch from the power source does not allow the switch to complete executing tasks and could lead to flash memory corruption.
  • Page 38: Updating Switch Firmware

    MSA1000 web site at www.hp.com/go/msa1000. See“Management System Requirements” on page 63 for information about connecting a workstation to the switch and refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for detailed information about Switch Manager and the CLI. Note: You can load and activate new firmware on an operating switch without disrupting data traffic or having to re-initialize attached devices.
  • Page 39 4. Enter the password for your account name. 331 Password required for johndoe. Password:****** 230 User johndoe logged in. The firmware is downloaded from the remote host to the switch, is installed, and is activated. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 40 Installing HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 41: Troubleshooting

    LEDs. Diagnostic information is also available through the Switch Manager and CLI event logs and error displays. This section describes the following diagnostics and tasks: POST diagnostics, page 42 Chassis diagnostics, page 46 Maintenance mode options, page 47 HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 42: Post Diagnostics

    Whether the problem is critical or not, contact your HP Authorized Maintenance Provider. If there are no errors, the Heartbeat LED blinks at a steady rate of once per second. If a critical error occurs, the Heartbeat LED shows an error blink pattern and the System Fault LED will illuminate.
  • Page 43: Internal Firmware Failure Blink Pattern

    A system error blink pattern is 3 blinks followed by a two second pause. The 3-blink error pattern indicates that a POST failure or a system error has left the switch inoperable. If a system error occurs, contact your HP Authorized Maintenance provider. Momentarily press and release the Maintenance button to reset the switch.
  • Page 44: Over Temperature Blink Pattern

    Figure 15: Logged-In LED location and blinking patterns See the following sections for information about identifying the cause of the error, and refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for information about correcting the error condition.
  • Page 45: Port Error Blinking Pattern

    Decode errors Login / Logout errors Loss-of-signal errors Port threshold alarm monitoring is disabled by default. Refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for information about managing port threshold alarms. If the count for any of these errors exceeds the rising trigger for three consecutive sample windows, the switch generates an alarm and disables the affected port, changing its operational state to “down.”...
  • Page 46: Chassis Diagnostics

    — No - Continue. 2. Inspect the AC power source. Is the power source delivering the proper voltage? — Yes - Continue. — No - Make necessary repairs. If the condition remains, contact your HP Authorized Maintenance Provider. System Fault LED is illuminated The System Fault LED illuminates to indicate that the switch logic circuitry is overheating or that a POST error has occurred.
  • Page 47: Maintenance Mode Options

    Exit Image Unpack Reset Network Config Reset User Accounts to Default Copy Log Files Remove Switch Config Remake Filesystem Reset Switch Show Firmware Versions Set Active Image 10) Update Boot Loader Option: HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 48: Maintenance Menu - Exit

    This option restores the switch configuration parameters to the factory defaults and deletes all other configurations from the switch. User account and zoning information is retained. Refer to the HP StorageWorks 2/8q Fibre Channel Switch Management User Guide for the default values.
  • Page 49: Maintenance Menu - Remake Filesystem

    Maintenance menu – Update Boot Loader This option updates the system boot loader. This is the program that loads the Linux kernel into memory. Use this option only at the direction of your HP Authorized Maintenance Provider. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 50 Troubleshooting HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 51: A Regulatory Compliance Notices

    HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 52: Modifications

    Hewlett-Packard Company P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 Or, call (281) 514-3333 To identify this product, refer to the Part, Series, or Model number found on the product. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 53: Canadian Notice (Avis Canadien)

    EN55024 (IEC61000-4-2, 3, 4, 5, 6, 8, 11) - Electromagnetic Immunity EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics EN61000-3-3 (IEC61000-3-3) - Power Line Flicker EN 60950 (IEC 60950) - Product Safety BSMI Notice HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 54: Japanese Notice

    Regulatory Compliance Notices Japanese Notice Japanese Power Cord Notice Korean notices Class A equipment HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 55: Laser Compliance

    The SFP Module contains a laser diode of either gallium aluminum arsenide (GaALAs) emitting in the wavelength range of 770-860 nm, or indium gallium arsenide phosphide (InGaAsP) emitting in the wavelength range of 1270-1355 nm. All HP systems equipped with a laser device comply with safety standards, including International Electrotechnical Commission (IEC) 825.
  • Page 56: Battery Replacement Notice

    Vanadium Pentoxide, batteries. There is a danger of explosion and risk of personal injury if the array is incorrectly replaced or mistreated. Replace only with the HP spare designated for this product. For more information about battery replacement or proper disposal, contact your HP Authorized Reseller or your HP Authorized Service Provider.
  • Page 57: Electrostatic Discharge

    Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the equipment suggested for proper grounding, either have an HP Authorized Reseller install the part or discharge any potential static by touching a piece of sheet metal immediately before touching the component or the device.
  • Page 58 Electrostatic Discharge HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 59: C Specifications

    (8) 2 Gbps FC ports Buffer credits 16 buffer credits per port, ASIC embedded memory Media type SFP optical transceiver, hot-pluggable Fabric port speed 2.125 Gbps Maximum frame size 2148 bytes (2112 byte payload) HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 60: Maintainability

    RJ-45 connector; 10/100 BASE-T cable Switch agent Allows a network management station to obtain configuration values, traffic information, and failure data pertaining to the Fibre Channels using SNMP through the Ethernet interface. HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 61: Dimensions

    5-500 Hz, random, 2.09 G rms, 10 minutes Shock IEC 68-2 Operating 4 g, 11ms, 20 repetitions Non-operating 30g, 292 ips, 3 repetitions, 3 axis Air flow Bezel side to port side HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 62: Regulatory Certifications

    CISPR 22, Class A EN 55022, Class A Voltage Fluctuations EN 61000-3-3 Harmonics EN 61000-3-2 Immunity EN 55024:1998 Marking FCC Part 15 (United States) (United States) cUL (Canada) cTUV (Canada) TUV Europe (Germany) VCCI HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 63: D Management System Requirements

    CD-ROM drive, RS-232 serial port, RJ-45 Ethernet port Internet browser Windows: Microsoft® Internet Explorer®, version 5.5 or greater Linux: Netscape Navigator, version 6.2 or greater or Mozilla , version 1.0.2 or greater with Personal Security Manager HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 64: Cable Pin Configurations

    With this type of connection, you can access the Command Line Interface. Table 12: Ethernet and serial Cable Pin Configurations Indirect Ethernet connection Direct Ethernet connection Serial connection straight cable cross-over cable null modem cable HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 65: Establishing An Ethernet Or Serial Connection

    3. Open a Telnet session by entering the following command with the switch IP address (Default IP address: 10.0.0.1): telnet 10.0.0.1 4. Log in to the switch. The default account name and password are ( admin password switch login: admin password: ******** HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 66: Serial Connection Information

    3. Log in to the switch. If fabric security is disabled, account names and passwords are not enforced. Refer to the command in the CLI portion of the HP StorageWorks 2/8q FC Switch Set Setup Management User Guide for information about setting fabric security. The default account name and password are (admin, password).
  • Page 67: Index

    LEDs indirect connection marking Link Status LED shock port vibration port location classes of service European Union notice configuration backing up file F_Port file system error 16, 43, fabric remove HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 68 27, non-critical error HyperTerminal application non-disruptive activation null modem F/F DB9 cable immunity inband management over temperature HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 69 14, rack stability location of symbols on equipment shock web sites Simple Network Management Protocol HP storage description workstation 63, 64, HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...
  • Page 70 Index worldwide name name server zone set zoning database zone limits access control list definition HP StorageWorks 2/8q Fibre Channel Switch Installation Guide...

This manual is also suitable for:

Storageworks 2/8q

Table of Contents