For Heavy Duty (FAS Models)
and
Median (FAM Models) Air Conditioners
Please read ALL instructions before installing. Two people are
recommended
to install this product.
If a new electrical outlet
is required,
have the outlet installed by a qualified
electrician
before installing
unit, See#5 in Preliminary Instructions
following.
Prelimi nary
instru ctions
Do the following before starting to install unit. See illustrations
below.
Check dimenstions
of your unit to determine
model type:
Heavy duty (FAS)
Median (FAM)
Unit Height:
18,5/8"
17.5/8"
Unit Width:
261/2"
231/2"
Min. Window Opening:
19"
181/2"
Min. Window Width:
31"
26 Vj'
Max. Window Width:
43"
40 V2"
1. Check window opening size- the mounting parts furnished
with this air conditioner
are made to install in a wooden
sill double-hung
window.The
standard
parts are for
window dimensions
listed above.Open
sash to a minimum
of 1g"(483mm).
(FIG. 1)
2.
Check condition of window-
all wood parts of window
must be in good shape and able to firmly hold the needed
screws.if
not, make repairs before installing
unit.
FIG. 1
_1SASH
19" MIN
1/2" MIN
STORM
WINDOW
FRAME
OR
OTHER OBSTRUCTION
FOAM
GASKET
WASHERHEAD
LOCKENG
SCREW_._._
X
ASSEMBLY
(LEFT)
SIDE RETAENER
J
BRACKET
3.
Check your storm windows= if you storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG.2, or by removing
storm window while room air conditioner is being installed.
(continued)
FIG. 2
//
SASH
f
19" MIN
1112
STORM WINDOW
FRAME OR
WITH TWO NAILS OR
OTHER OBSTRUCTION
SCREWS.
P/N 6612990 1162
1

Advertisement

loading

Summary of Contents for Frigidaire L0806995

  • Page 1 Check your storm windows= if you storm window frame does not allow the clearance required, correct by adding a piece of wood as shown in FIG.2, or by removing storm window while room air conditioner is being installed. unit. (continued) 19"...
  • Page 2 Power supply core NIth 3-prong groundi plug and current detection device 6. Carefully unpack air conditioner material. Protect floor or carpet from damage. Two people should be used to move and install unit. for things Inside, be sure cord...
  • Page 3: Remove Chassis

    9. Your unit may come with internal packaging.THIS PACKAGING MUST BE REMOVED PRIOR TO INSTALLING THE AIR CONDITIONER INTO THE CABINET. (See FIG. 5). Install and Side Bracket Attach foam gasket to top angle above holes as shown in FIG.
  • Page 4 3. Insert top and bottom legs of window filler panel frame into channel in the to angle and bottom rail. Do both sides. Insert washer head locking screws (2) into holes in top leg d filler panel frame (see Step 6). Do not totally tighten.
  • Page 5 LOCK 3/4" }orlg hex- install Filler Cabinet Front to Unit 1, Lift air conditioner leaving 6" protruding, 2. _DO 3, Be sure chassis is firmly seated towards rear of cabinet. 4. Installation of front is the reverse of removal outlined in Section 1.
  • Page 6: Installation

    NOTE: Consult local building codes prior to installation, or a qualified carpenter. Select Wall Location This air conditioner has a slide-out chassis, so that it can be installed through an outside wall as specified below: Heavy Duty(FAS) Max wall thickness 10"...
  • Page 7 NOTE: If wall thickness is 8-1/2" or more, add aluminum flashing over bottom of frame opening to assure no water can enter area between inner and outer wall. ALUMINUM FLASHING OVER BOTTOM OF FRAME Prepare and Install Cabinet 1. Slide chassis from cabinet. Refer back to Step 1 of Window Mounting.
  • Page 8: Masonry Construction

    OPTIONAL: Caulking and installation wall may be done. You can buy wood from your local lumber or hardware supply. On the outside, caulk openings and sides of cabinet, and all sides of wood sleeve to the opening. NOTE: See Step 7, Item 3 of Window Mounting for bottom rail seal location.

This manual is also suitable for: