Message Information
CPU0704
Message
LCD Message
Details
Action
CPU0801
Message
LCD Message
Details
Action
CPU0802
Message
Details
Action
CPU0803
Message
LCD Message
Details
88
number > machine check error detected.
CPU <
CPU <
number > machine check error detected. Power cycle system.
System event log and operating system logs may indicate that the
exception is external to the processor.
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn system off and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn system on.
5. If the issue persists, see
number > voltage regulator module failed.
CPU <
number > voltage regulator module failed. Re-seat module.
CPU <
System performance may be degraded or the system may fail to
operate.
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see
A predictive failure detected on CPU <
module.
System performance may be degraded or the system may fail to
operate.
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see
The power input for CPU <
Lost power input for CPU <
module.
System performance may be degraded or the system may fail to
operate.
Getting
Help.
Getting
Help.
number > voltage regulator
Getting
Help.
number > voltage regulator module is lost.
number >voltage regulator module. Re-seat