Table 5.12 Contents of SECURITY SET PASSWORD data
Word
0
1 to 16
17 to 255
Table 5.13 Relationship between combination of Identifier and Security level, and
operation of the lock function
Indentifier
Level
User
High
Master
High
User
Maximum
Master
Maximum
Contents
Control word
Bit 0 Identifier
0 = Sets a user password.
1 = Sets a master password.
Bits 1 to 7 Reserved
Bit 8 Security level
0 = High
1 = Maximum
Bits 9 to 15 Reserved
Password (32 bytes)
Reserved
The specified password is saved as a new user password. The
lock function is enabled after the device is turned off and then
on. LOCKED MODE can be canceled using the user password
or the master password already set.
The specified password is saved as a new master password. The
lock function is not enabled.
The specified password is saved as a new user password. The
lock function is enabled after the device is turned off and then
on. LOCKED MODE can be canceled using the user password
only. The master password already set cannot cancel LOCKED
MODE.
The specified password is saved as a new master password. The
lock function is not enabled.
C141-E090-01EN
Description
5 - 61