PERFORMANCE DATA SHEET
Base Grille Water Filtration
System
Model T1 KB2/T1 RFKB2 Capacity
200 Gallons (757 Liters) without
Filter Indicator
Light
System tested
and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the
reduction
of Lead, Mercury, Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity,
Asbestos,
Lindane,
Tetrachloroethylene,
Endrin, Alachlor,
Chlorobenzene
and Ethylbenzene.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances
listed below. The
concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the
permissible
limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53.
Substance
Reduction
Aesthetic Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
Atrazine
Asbestos
Live Cysts _
Turbidity
Alachlor
Endrin
Ethylbenzene
Lindane
Chlorobenzene
Tetrachloroethylene
NSF Reduction
Average
Influent Challenge
Requirements
Influent
Concentration
50% reduction
2.0 mg/L
2.0 mg/L + 10%
85% reduction
3533333#/mL
At east 10,000 partces/mL
NSF Reduction
Average
Influent
Challenge
Requirements
Influent
Concentration
0.010 mg/L
150 ug/L
0.15 mg/L + 10%
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
0.002 mg/L
0.0058 mg/L
0.006 mg/L + 10%
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.6 mg/L
1750 ug/L
1.8 _+ 10%
0.003 mg/L
15 ug/L
0.015 _+10%
0.003 mg/L
10 ug/L
0.009 mg/L _+10%
99%
101 MFL
1OTto 108fibers/L tt
>99.95%
120,000/L
50,000/L min.
0.5 NTU
11.4 NTU
11 _+1 NTU
0.002 mg/L
41.3 ug/L
0.04 _+10%
0.002 mg/L
5.9 ug/L
0.006 _+10%
0.7 mg/L
1867 ug/L
2.1 _+10%
0.002 mg/L
1.9 ug/L
0.002 _+10%
0.6 mg/L
2.0 ug/L
2.0 _+10%
0.005 mg/L
14.2 ug/L
0.015 _+10%
Maximum
Effluent
0.08 mg/L
**
22000 #/mL
Maximum
Effluent
1 .Oug/L
2.0 ug/L
0.0002 mg/L
0.0002 mg/L
0.5 ug/L
1 .Oug/L
1 .Oug/L
2 ug/L
0.17 MFL
8/U
0.41 NTU
0.2 ug/L
0.5 ug/L
0.70 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
Average
Effluent
2.0 mg/L
11567 #/m L
Average
Effluent
1 ug/L
1.08 ug/L
0.0002 mg/L
0.0002 mg/L
0.5 ug/L
1.O ug/L
1 .O ug/L
2 ug/L
0.17 MFL
1/ U
0.24 NTU
0.2 ug/L
0.3 ug/L
0.0588 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
Minimum
%
Reduction
95.93
99.38
Minimum
%
Reduction
99.33
98.72
96.53
96.5
96.67
99.94
93.33
80.8
99.83
99.99
96.4
99.52
91.5
99.96
98.93
99.98
96.47
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 200 gallons
(757 liters).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Model
T1KB2:
Change the water filter cartridge
every 6 months.
If the water flow to the water dispenser
or ice maker decreases
noticeably
before 6 months
have passed,
replace the water filter
cartridge
more often.
Use replacement
cartridge
T1 RFKB2, part #9030.
2008 suggested
retail price of $59.99
U.S.A./S71.99
Canada.
Prices are subject
to change without
notice.
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality
without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters
that may contain
filterable
cysts.
Average
%
Reduction
97.36
99.67
Average
%
Reduction
99.33
99.31
96.53
96.5
96.67
99.94
93.33
80.8
99.83
>99.99
97.89
99.52
95.47
100
98.93
99.98
96.47
Refer to the "Warranty"
section
for the Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply Parameters
Water Supply
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL
of AC Fine Test Dust.
ttFibers greater than 10 um in length
€Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark of NSF International.