Whirlpool EV200 Service Pointer

Defrost drain icing up

Advertisement

Quick Links

THIS SERVICE POINTER APPLIES TO THE FOLLOWING BRANDS:
P
Ice in Drain and on
Freezer Floor
Defrost Drain Icing Up
No Frost Models EV200 & EV150
COMPLAINT:
Water running onto freezer floor and then freezing.
CAUSE:
Not enough heat radiating into defrost drain area to keep
ice from building up during defrost.
CORRECTION:
Remove ice from freezer floor and defrost drain area and
install Heat Shield Kit #4357284. See Figure 1.
Evaporator Cover
FIGURE 1
FIGURE 1
FIGURE 1
FIGURE 1
FIGURE 1
Drain Trough
(continued)

Advertisement

loading

Summary of Contents for Whirlpool EV200

  • Page 1 THIS SERVICE POINTER APPLIES TO THE FOLLOWING BRANDS: Defrost Drain Icing Up No Frost Models EV200 & EV150 COMPLAINT: Water running onto freezer floor and then freezing. CAUSE: Not enough heat radiating into defrost drain area to keep ice from building up during defrost.
  • Page 2 The kit contains the following: Hold the heater assembly by the insulated end 4 each Nylon Ties caps. Touching the glass with your fingers will 1 each Heat Shield deposit salt on the glass and cause early failure. 3 each Aluminum Pop-Rivets Be careful not to pull the end caps off the glass 1 each Instruction Sheet tube.

This manual is also suitable for: