Download Print this page

Sanyo TravelMate P245-M Manual page 5

Shipping document

Advertisement

UN Test Data
1.Test Item: Altitude simulation (T1)
2.Test Purpose: This test simulates air transport under low-pressure conditions.
3.Test Procedure:
Test cells and batteries shall be stored at a pressure of 11.6kPa or less for at least six hours at ambient
temperature(20±5• Ž ).
SANYO Internal Procedure:
As above.
4.Test Requirements:
No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage
retention is not less than 90%.
The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date:
2007/10/11
6.Test Data
Mass(g)
Battery No.
Before test After test
1
294.50
At first
cycle,in
2
293.74
fully
3
294.34
charged
states
4
294.02
5
294.69
At first
cycle,in
6
294.80
fully
7
294.79
discharged
states
8
294.49
After 50
9
294.13
cycles
10
294.68
ending in
fully
11
294.68
charged
12
294.05
states
After 50
13
294.55
cycles
14
294.59
ending in
fully
15
294.12
discharged
16
294.41
states
Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire,
0-No leakage, no venting, no disassembly, no rupture & no fire
(Model:3UR18650-2-T0590)
Mass
loss (%)
Before test After test
(=<0.1%)
294.50
0.000
293.71
0.010
294.30
0.014
294.02
0.000
294.67
0.007
294.79
0.003
294.76
0.010
294.50
0.003
294.13
0.000
294.68
0.000
294.67
0.003
294.05
0.000
294.55
0.000
294.60
0.003
294.12
0.000
294.38
0.010
Voltage
Voltage(V)
Retention(
%)(=>90%)
12.55
12.52
99.8
12.54
12.52
99.8
12.55
12.52
99.8
12.55
12.52
99.8
12.56
12.55
99.9
12.56
12.55
99.9
12.56
12.56
100.0
12.56
12.56
100.0
P.3/10
Other
Result Judgement
event
PASS
0
PASS
0
PASS
0
PASS
0
0
PASS
0
PASS
0
PASS
0
PASS
PASS
0
PASS
0
PASS
0
PASS
0
PASS
0
PASS
0
PASS
0
PASS
0
PASS