LG DLE3733S Owner's Manual page 14

Electric and gas dryer
Hide thumbs Also See for DLE3733S:
Table of Contents

Advertisement

Available languages

Available languages

s
(Ga: dryer only).
In addition
to the following,
please refer to manual section on Gas Requirements
and Instructions.
1. New stainless
steel flexible
connector.
Use this type of
connector
only if allowed
by local codes.
Use Design
AGA
Certified
Connector.
2. 1/8" NPT Pipe Plug (tUr checking
inlet gas pressure)
3. Equipment
Shut-Off
Valve
Installed
within 6' (1.8 m) of dryer.
4. Iron Pipe.
Shorter
than 20'
(6.1 m)
Use 3/8" pipe.
Longer
than 20' (6.1 m) - Use 1/2" pipe.
5.3/8"
N.P.T.
Gas Connection.
Make sure the burner orifice is proper for the type of
For instance, using LPG with LNGorifice will result
in death, fire or explosion. Or using LNG with LPG
nozzle will not allow the burner to ignite.
If needed, orifice conversion should be done by a
qualified service technician and mark or put the
label of the current type of orifice on the dryer.
If changing the orifice, also adjust the gas valve.
I. Confirln that the type of gas available in your laundry
room is appropriate
IBr the dryer. The dryer is prepared
3
T_
o
*
IBr Natural Gas with a, 18 NPT _as connection.
2. Remove the shipping cap fiom the gas connection
at the
back of the dryer. Make sure that you don't damage the
threads of the gas connection pipe when you remove the
shipping cap.
3. Connect the dryer to your laundry room's gas supply
using a new flexible stainless steel connector (as noted
below, use a new stainless steel flexible connector if
allowed by your local codes).
4. Securely tighten all connections
between the dryer and
your laundry room's gas supply. Turn on your laundry
room's gas supply and check all pipe connections
(both
internal and external) for gas leaks with a non-corrosive
leak detection fluid. Refer to Part 7 (page 20)
5. For LP (Liquefied Petroleum) gas connection, refer to
this manual's section entitled Gas Requirements
and
Instructions.
14
Following are several warnings and instructions
concerning
makiug the electrical connection
for electric
dryers. More detailed iutbrmatiou
concerning the
electrical connection
is provided in the manual section
entitled Electrical Requirements
for Electric Dryer.
It is important that you thoroughly
review that section
and the remainder
of this manual, belBre taking any
steps to install or use this dryer.
1. Use only a new UL listed No. 10 (copper wire only)
three conductor power supply cord kit rated 240
Volts (minimum)
30 Amperes and labeled as suitable
l_r use in a clothes dryer.
2. A four-wire cord is required for manufactured
(mobile) home installations
and where local codes do
not allow grounding of this appliance through
neutral.
3. Electrical
Plug Connections.
4. For additional instruction on connecting
the dryer to
an electrical power source, please refer to this
manual's section on Electrical Requirements
and
Electric Dryer.
Burner input requirements
if your house is located at the elevations up to
10,000 feet.
Adjustingburner input setting iS not needed at this
elevation because AGAcertifies this dryer will not have
any problemwith the BTUrating at this altitude.
if your houseis above 10,ooo feet, you are required to
adjust a four percent (4%) reduction of the burner BTU
rating indicated on the model/serial rating
WARNING!
• Use a new UL listed 30 amp power supply cord
• Use a UL approved strain relief
• Disconnect power before making electrical
connections
• Connect neutral wire (white or center wire) to
center terminal
• Ground wire (green or bare wire) must be
connected to green ground connector
• Securely tighten all electrical connections
• See installation instructions for complete
instructions
• Failure to do so can result in fire or electrical
shock

Hide quick links: