Whirlpool CEM2750JQ0 Installation Manual

Commercial gas/electric dryer

Advertisement

Quick Links

IMPORTANT:
Read and save
these instructions
COMMERCIAL
DRYER
IMPORTANT
Installer:
Leave Installation
Instructions
with the owner.
Owner: Keep Installation
Instructions for
futurereference.
Save Installation
Instructions forlocal
electrical i nspector's use.
120-volt, 60 Hz
www.whirlpool.oom
Part No, 8316558 Rev, A
ELECTRIC
120/240-volt,
60 Hz
COMMERCIAL
LAUNDRY
PRODUCTS

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool CEM2750JQ0

  • Page 1 Read and save COMMERCIAL these instructions DRYER ELECTRIC IMPORTANT Installer: Leave Installation Instructions with the owner. 120-volt, 60 Hz 120/240-volt, 60 Hz Owner: Keep Installation Instructions for futurereference. Save Installation Instructions forlocal electrical i nspector's use. COMMERCIAL www.whirlpool.oom LAUNDRY PRODUCTS...
  • Page 2: What To Do If You Smell Gas

    IMPORTANT SAFETY INSlRUCE)NS ]B 'ore you start... WARNING_ To mclu_ '1_ dskof I_, et_hi¢ shock, _ inlu_ to I_rsom wi_m Your safety and the safety of others are very important. mir1_l y our c_llcmce, foEow bl:_¢ precautions,including the following: We have provided many important 1.
  • Page 3: Exhaust Requirements

    Whirloool Service Manual °Exhausflng and cleaned yearly, 2. Turn the timing cam by hand until Whirlpool D ryers/Part No.603197, the "V" -shaped notch lines up Replace any plastic or metal foil exhaust avaliable f rom yourWhirlpool p arts...
  • Page 4: Gas Requirements

    Back-droft Damper Kits,PartNo. Do Net install screening orcap over 3391910, areavailable f rom your end ofvent, This installation must conform Whirlpool d ealerand shouldbe installed ineach dryer's exhaust vent with local codes, or in absence to preventexhaustedair from local codes...
  • Page 5: Recommended Ground Method

    A 120-volt, 60-Hz, AC-only, 15-or Check that dryer is equipped m If local codes and ordinances 20-ampere fused electrical supply is with the correct burner for the permit, it is recommended that new required. A time-delay fuse or circuit particular type of gas used.
  • Page 6 Now Start... m Remove the service door of the TO exhaust dryer, see Exhaust meter case, Lift requirements, Pages 3-4. Connect With dryer in laundry area. the service door exhaust vent system to dryer exhaust up at the back outlet and exhaust hood using 4"...
  • Page 7: Electrical Requirements

    Now Start... 5m Remove the service door of the Electrical meter case, Uft the service door requirements Excessive Weight Hazard up at the back and remove. Use two or more peopleto move and if codes permit and o separate Install money- install dryer, ground wire is used, It Is accepting...
  • Page 8: Grounding Instructions

    WARNING - Improper connection l)tmct wire (o.s. 7 = U.S. installations: the equipment-grounding conductor can result in a risk of electric shock. Make electrical connection. Check with a qualified electrician or Thisdryer is manufactured with the service representative or personnel if cabinet-ground conductor you are in doubt as to whether the connected to the NEUTRAL (center) of...
  • Page 9 Four-wire connection... Four-wire receptacle (required for mobile home., 4. Remove center terminal block screw. 5. Remove appliance ground wire (green with yellow stripes) from external ground connector screw. Fasten under center, silver-colored terminal block screw. Connect ground wire (green) power supply cord to external...
  • Page 10 Three-wire connection... Three-wire receptacle Where local codes permit connecting cabinet-ground conductor to neutral wire: Loosen or remove center terminal block screw. 5. Connect the neutral wire (white, or center) of power supply cord to the center, sUver-colored terminal screw of the terminal block.
  • Page 11 Three-wire connection... Three-wire receptacle Where local codes Do Not permit connecting cabinet-ground conductor to neutral wire: After reattaching the terminal cover, connect a separate copper ground wire from the external Remove center terminal block Three-wire power supply cord must ground connector screw to an...
  • Page 12: Recessed Area And Closet Installation Instructions

    Companion appliance spacing • Shut off the gas supply valves in the should be considered, The Whirlpool Consumer Interaction gas supply line. Center will answer any questions The dryer must be exhausted • Disconnect gas pipe and fittings...
  • Page 13: Product Dimensions

    Product dimensions 29" (73.7 cm) dryer <--25- I12" (64.8 cm) -_ __-_--t 29" (73.7 cm)-_ / ..I"... non-coin-operated models: ELECTRIC_ ..7-I/8" (18.1 cm) 3S" (88.9 cm) coin-operated models: (40,6 cm) 7-7/8" (20 cm) 27-114" 4-3/4" 13" 4_ (I 0.2 cm) (69.2 cm) (12,1 cm) dla.

Table of Contents