Basic Performance (High capacity/High speed)
The high-level basic performance provides sufficient room for future
equipment expansion as well as a rich variation.
■ Abundant program capacity -
The program capacity of 32 ksteps, exceeding the capacity of most compact PLCs,
can flexibly handle a wide variety of applications requiring future equipment
expansion. An adequate comment area has of course been reserved. Free comment
entry makes the program easy to understand during verification.
■ Equipped with an independent comment memory
Equipped with an independent comment memory separate from the program memory.
100,000
All of
I/O comments,
of remark comments are saved in FP-X together with programs.
*Input comments do not decrease the program capacity.
■ High-speed scan at
High-speed processing is often required for small-scale equipment control
such as serial data communication, network construction or PID temperature
control. High-speed scanning at 0.32 µsec/step (basic instruction) easily meets
such requirements.
(Ex.) In the case of a 5-kstep program consisting of 40% basic instructions
and 60% applied instructions (Data tansfer and operation instructions),
Scan time:
Controls Specifications
Item
Program method
Control method
Program memory
Program capacity
Operation processing speed
Basic instructions
Applied instructions
External inputs (X)
External outputs (Y)
Internal relay (R)
Special internal relay (R)
Link relay (L)
Timer/counter (T/C)
Data register (DT)
Link data register (LD)
Special data register (DT)
Index register (I0 to ID)
Master control relay (MCR)
Number of labels (LOOP)
Number of differentiations
Number of stepladders
Number of subroutines
Number of interruption programs
*2
High-speed counter
*1 The actual usable number of points is restricted by the hardware.
*2 Specification at the rated input voltage of 24 V DC, 25°C. Frequency may be lower due to the voltage and
temperature. The countable frequency also changes depending on the number of channels used.
*3 The pulse I/O cassette cannot be used for the control units (transistor output type).
6
32
ksteps (16 ksteps for C14)
5,000
lines of line-space comments, and
0.32
µsec for instruction processing
1.9 ms
(measured time)
Specifications
Relay symbol method
Cyclic operation method
Flash ROM built-in (no battery backup required)
16 ksteps (C14), 32 ksteps (C30, C60)
Basic instruction 0.32 µs/step
111
216
*1
1760 points
*1
1760 points
4096 points
192 points
2048 points
Total 1024 points: timer capable of counting
(1 ms, 10 ms, 100 ms, 1 s) x 32767
Counter capable of counting 1 to 32767
12285 words (C14), 32765 words (C30, C60)
256 words
374 words
14 words
256 points
256 labels
Up to program capacity
1000 stages
500 subroutines
Relay output type: 15 programs (14 external, 1 constant)
Transistor output type: 9 programs (8 external, 1 constant)
Built-in (Transistor output): single-phase 8 ch (50 kHz x 4 ch + 10 kHz x 4 ch)
Built-in (Relay output): single-phase 8 ch (10 kHz x 8 ch)
*3
Pulse I/O cassette
: single-phase 2 ch (80 kHz x 2 ch)
●Program capacity
C30, C60
C14
5,000
lines
●Processing speed of the basic
Item
Built-in (Transistor output): 100 kHz x 2 ch + 20 kHz x 2 ch
*4
Pulse output
Pulse I/O cassette (for the relay output type only):
One unit (one axis) 100 kHz, or two units (two axes) 80 kHz
Relay output type: Total 14 points (including the high-speed counter)
Pulse catch input / interrupt input
Transistor output type: Total 8 points (including the high-speed counter)
Periodical interrupt
0.5 ms to 30 s
Potentiometer
2 points (0 to 1000) (C14, C30) 4 points (0 to 1000) (C60)
Constant scan
Possible
Real-time clock
Equipped (usable only when AFPX-MRTC is installed)
Flash ROM
Backup by F12,
Data register (32765 words)
*7
backup
P13 commands
Counter 16 points (1008 to 1023), Internal relay 128 points
Auto-backup
at power failure
(R2480 to R255F), Data register 55 words
The memory allocated in the storage area by the
Battery backup
system register (only when a battery is installed)
C14: 1230 days (actual operation 10 years at 25°C)
Before installing
Battery life
AFPX-MRTC
C30, C60: 990 days (actual operation 10 years at 25°C)
(when no power is
C14: 780 days (actual operation 10 years at 25°C)
supplied)
After installing
AFPX-MRTC
C30, C60: 680 days (actual operation 10 years at 25°C)
(More than two batteries can be installed in C30 and C60.
In this case, the battery life is extended several times)
Password
Capable (4 or 8 characters selectable)
Self-diagnosis function
Watch dog timer, program syntax check
Capable (328 KB) (backup battery not required)
Comment storage
All of I/O comments, remark comments, and line-space comments can be stored.
Max 16 units, link relay 1024 points, link register 128 words
PLC link function
(No data transfer or remote programming)
Rewriting in RUN mode
Capable
*4 Max frequency may vary by the method of operation. Please refer to the manual for details.
*5 Calendar accuracy at 0°C: 119 sec/month or less, 25°C: 51 sec/month or less, 55°C: 148 sec/month or
less (Real-time clock requires a battery.)
*6 When data is stored in the storage area while the battery is not installed, the data is not cleared and the
data value may be indefinite. The same condition occurs when the battery is exhausted.
*7 The number of possible rewrites is 10,000 or less.
FP-X
C30/C60
32
FP-X
C14
16
k
FP0
10
k
10k
20k
30k
instructions (ST, OR, AND, OT etc)
0.32
µsec
FP-X
0.9
µsec
FP0
0.5
Specifications
k
steps
µsec
1.0
*5
*6