To Charge the Battery Pack
1. The B-EP800-CHG6-QM-R battery charger is exclusively used for the B-EP802-
BT-QM-R/ B-804-BT-QM-R lithium-ion battery pack. DO NOT charge any other
battery packs, or explosion, combustion, or overheating may result.
2. If the battery charger gives out smoke, a bad smell, or extraordinary heat, unplug
the power cord from the outlet immediately. Failure to do this may cause fire or
electric shock.
Please use the following procedure to charge battery packs (B-EP802-BT-QM-R/B-
EP804-BT-QM-R). This battery charger can charge six battery packs at the same
time with the B-EP802-BT-QM-R and the B-EP804-BT-QM-R mixed.
1. Fit the partition into the slot. The
orientation of the partition differs
depending on the battery pack size (B-
EP802-BT-QM-R or B-EP804-BT-QM-R)
to be charged.
NOTE:
• Fit the partition in the correct position and
orientation and make sure the tabs are fit
into the holes.
• Be careful not to loose the partition.
• Care must be taken not to mistake the orientation, as the
partition cannot be removed once it is fitted
2. Connect the AC adapter to the battery
3.
Connect the power cord to the AC adapter.
4.
Connect the power cord to an AC outlet.
3. If the over discharge protector has been operated on a battery pack, the
CHARGE lamp may not light for a while. Leave the battery charger and the battery
pack alone for a few minutes. Stop using the battery pack if the CHARGE lamp
does not light at all as the battery pack may be faulty.
4. After the charging is completed, do not leave the battery pack in the charger too
long. The battery pack gradually discharges.
5. The battery pack can be removed from the battery charger while charging is in
progress. However, the battery lasting time depends on the charging time.
6. Periodically clean the charger terminals with a soft dry cloth.

TROUBLESHOOTING

If you have any problems during using this product, please check the following point first.
If a problem cannot be solved by taking actions described below, unplug the battery charger and
contact the dealer or an authorised TOSHIBA TEC service representative for assistance
Symptom
• The power cord or AC adapter is not connected properly.
A battery pack is loaded in the
⇒ Firmly connect the power cord or AC adapter.
battery charger, but the CHARGE
lamp does not light up in red
• The terminals of the battery charger or the battery
electrodes are stained.
⇒ Wipe clean those portions with a soft dry cloth.
• You are attempting to charge a battery pack with the over
discharge protection activated (The CHARGE lamp may not
light up immediately after loading a battery.)
⇒ Leave the battery charger and the battery pack alone
for a few minutes. If the CHARGE lamp does not light after
all, stop using the battery pack, as the battery pack may
be faulty.
• The partition is not fitted.
⇒ Fit the partition in the correct orientation.
• A battery pack failure is detected.
The CHARGE lamp blinks in red.
⇒ It could be the end of battery life. Replace the battery
• Charging time varies depending on the condition of the
Charging time overruns the
battery pack, ambient temperature, etc.
approximate specified time.
⇒ If the battery charger continues charging even after the
• It could be the end of battery life.
Battery does not last long time
though the battery is fully charged.
⇒ Replace the battery pack with a new one.
• The partition is not set completely.
The battery pack cannot be inserted
into the slot.
⇒ Fit the partition completely.
WARNING!
When charging
B-EP802-BT-
Tab
QM-R battery
pack
Battery Charger
charger.
AC Adapter
8
Cause and resolution
pack with a new one.
specified time has passed, stop charging and replace
the battery pack with a new one.
10
5.
Insert the battery pack into the slot in the
orientation shown below.
The CHARGE lamp will light up and
charging will begin.
Notice:
Insert an appropriate size of the battery pack
according to the partition's orientation.
Failure to do this may damage the battery
pack or affect charging operation.
The CHARGE lamp indicates a charging status.
CHARGE lamp
Tab
When
charging B-
EP804-BT-
QM-R
battery pack
6. After charging is completed, remove the battery pack from the battery charger.
7. Disconnect the power cord from the AC outlet.

Charging time

To charge an empty battery pack:
Battery pack
B-EP802-BT-QM-R
B-EP804-BT-QM-R
AC Outlet
• Charging time may differ depending on the condition of the battery pack or the
operating temperature.
• After the CHARGE lamp turns from red to green, the battery charger may
continue to charge the battery pack for up to one more hour until the full charge
level (95% or more).
Power Cord
NOTES:
1. Battery packs should be charged on condition that both ambient temperature
and battery temperature fall within a range of 0 °C to 40°C.
2. The battery charger will get warmer during charging (room temperature + about
30°C). This is not abnormal.

Specifications

Model
Power requirements:
Output voltage:
Application:
Number of slots
Operating temperature:
Operating humidity:
Storage temperature:
Storage humidity:
Dimensions:
Weight:
Accessory:
NOTE: Design and specifications are subject to change without notice.
State
OFF
Unconnected.
Red
Charged.
Green
Completed.
Blinking red
Abnormal state
about 3 hours
(Until min. of 85% of the nominal capacity is charged.)
about 3 hours
(Until min. of 85% of the nominal capacity is charged.)
9
Item
Charger
B-EP800-CHG6-QM-R
DC +19V, 7.89A (Supplied by the AC
adapter)
-------
TOSHIBA battery pack
B-EP802-BT-QM-R
B-EP804-BT-QM-R
6 slots (Every slot can charge a battery
pack independently.)
The battery pack model is automatically
sensed
0°C to 40°C (32°F to 104°F)
20 to 80% (no condensation)
-20°C to 60°C (-4°F to 140°F)
10 to 85% (no condensation)
148 x 77 x 213 mm (w/h/d)
(5.83" x 3.03" x 8.39") excluding the
projecting parts
Approx. 900 g (31.7 oz)
(Excluding the accessories.)
AC adapter x 1, Partition x 6, Owners Manual x 1
11
Battery Pack
Partition
CHARGE lamp
NOTE:
The green lamp does not go off until the
battery pack is removed from the slot.
Charging time
AC Adapter(Accessory)
F11503-B
100 to 240V AC, 50/60 Hz
DC 19V, 7.89A
TOSHIBA 6-slot Battery
Charger
B-EP800-CHG6-QM-R
-------
84.5 x 40.7 x 170 mm
(w/h/d)
33.3"
x
1.6"
x
6.69")
excluding the projecting
parts
Approx. 650 g (22.9 oz)

Advertisement

loading