Fusing of Tungsten Halogen Studio and Theatre Lamps
A lamp normally fails at end of life by fusing of the filament. Often an arc then forms and as there is
little resistance to limit the current this rises to a very high value which if maintained can result in a
serious overload on the envelope and seals. This might result in the lamp shattering. A quick acting
high breaking capacity fuse must be connected in the supply line in all applications. Suitable types are
given in BS88 (IEC 269), IEC 127 or IEC 241.
lamp
power
(watts)
500
650
1000
1500
2000
2500
5000
10000
fuse (rated current)
(amps)
100-115V
6
10
16 (15 UK)
20
25 (30 UK)
35 (30 UK)
63 (60 UK)
125
115-130V
220-250V
6
4
6
4
10
6
16 (15 UK)
10
25 (20 UK)
10
25 (30 UK)
16 (15 UK)
50
25 (30 UK)
100
50