Power supply specifications

Table 32 lists power supply specifications for the PowerEdge R620.
Specification
1100W DC
Current
consumption
Supply voltage
-48V to -60V DC
Frequency
Heat dissipation
(BTU/hr max)
Maximum inrush
2
current
1
Auto-ranging
2
Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55A per
power supply for 10ms or less.

Environmental specifications

Table 33 details the environmental specifications for the R620. For additional information about
environmental measurements for specific system configurations, see
Dell.com/environmental_datasheets.
Fresh Air: temperature, humidity, altitude de-rating
Continuous
10°C to 35°C (50°F to 95°F) at 10% to 80% relative humidity with 26°C (78.8°F) maximum
operation
dew point (maximum wet bulb temperature). De-rate maximum allowable dry bulb
temperature at 1°C per 300m above 950m (1°F per 547 ft above 3117 ft).
Expanded
When operating in the expanded temperature range, system performance may be impacted,
operation
and ambient temperature warnings may be reported on the LCD and in the System Event
Log.
≤ 10% of annual operating hours: 5°C to 10°C and 35°C to 40°C (with no direct sunlight on
the equipment) at 5% to 85% relative humidity with 26°C dew point (maximum wet bulb
temperature). Outside the standard operating temperature (10°C to 35°C), the system can
operate down to 5°C or up to 40°C for a maximum of 10% of its annual operating hours. For
temperatures between 35°C and 40°C (95°F to 104°F), de-rate maximum allowable dry bulb
temperature by 1°C per 175m above 950m (1°F per 319 ft above 3117 ft).
≤ 1% of annual operating hours: –5°C to 5°C and 40°C to 45°C (with no direct sunlight on
the equipment) at 5% to 90% relative humidity with 26°C dew point (maximum wet bulb
temperature). Outside the standard operating temperature (10°C to 35°C), the system can
operate down to –5°C or up to 45°C for a maximum of 1% of its annual operating hours. For
temperatures between 40°C and 45°C (104°F to 113°F), de-rate maximum allowable dry bulb
temperature by 1°C per 125m above 950m (1°F per 228 ft above 3117 ft).
Expanded operation restrictions:
No cold startup below 5°C
Maximum altitude for the operating temperature must be 3050m (10,000ft)
Redundant power supplies required
52
PowerEdge R620 Technical Guide
Table 32.
Power supply specifications
1100W AC
32A
12A–6.5A
100–240VAC
N/A
50/60Hz
4416
4100
55A
55A
Table 33.
Environmental specifications
750W AC
Titanium
10A–5A
1
200–240VAC
50/60Hz
2843
55A
750W AC
495W AC
Platinum
6.5A–3A
10A–5A
1
100–240VAC
100–240VAC
50/60Hz
50/60Hz
1908
2891
55A
55A