Electrolux EFC 009 X User Manual

Electrolux cooker hood

Advertisement

Gebrauchsanweisung, Manuel d'utilisation
EFC 009 X
Istruzioni per l'uso, User Manual
D
F
I
UK

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux EFC 009 X

  • Page 1 Gebrauchsanweisung, Manuel d'utilisation EFC 009 X Istruzioni per l'uso, User Manual...
  • Page 2: Table Of Contents

    Contents Safety instructions ......................35 Description of the appliance....................36 Mounting of grease filters ..........................36 Function ..........................36 Exhausting version ............................. 36 Recycling version ............................... 36 Special accessories ......................37 Active carbon filter ............................. 37 Installation ..........................37 Unpacking ................................37 Placement ................................
  • Page 3: Safety Instructions

    Congratulations to your new Cooker Hood Thank you for your choice of an Electrolux product. We are convinced that you will have great use and pleasure from your new cooker hood. Before you use the cooker hood we recommend that you read through the whole user manual giving a direct description of the cooker hood and its functions.
  • Page 4: Description Of The Appliance

    Description of the appliance 1. Control panel 2. Operating light 3. Grease filters Standard accessories included: Screws for mounting No return valve (mounted on air outlet) Drilling scheme Connection ring Deflector (Recycling version) Fig. 1 Mounting of grease filters The grease filters are supplied apart inside an apposite package;...
  • Page 5: Special Accessories

    Special accessories Active carbon filter When the hood is used in recirculation mode an active carbon filter should be used. Order by the retailer PNC 942 120 182 Installation Unpacking Check that the cooker hood has no damages. Transportation damages should immediately be reported to the one responsible for the transport Damages, faults and eventually missing details should immediately be reported to the seller.
  • Page 6: Mounting Of Hood

    Mounting of hood First set the telescopic support structure on the right direction and drill as indicated on the drilling scheme supplied with the hood. The two sections of the structure are fixed one each other with 8 screws (fig. 5- "a"). Remove all screws, regulate the lenght of the structure according the exigencies, fit again the 8 screws.
  • Page 7: For Both Version

    For both versions: Fix the supporting structure to the ceiling with 4 screws 5x45 and dowel (b - Fig. 5). Sides with fixing points "c" for the external telescopic chimney correspond to the right and left sides (fig. 5). The hood is supplied with installation fittings suitable for most kinds of ceilings, but in any case a qualified installation technician must be consulted in order to choose the best...
  • Page 8: Mounting Of Carbon Filter (For Recirculating Version)

    Mounting of carbon filter (for recirculating version) Remove the grease filters. Fix the carbon filter with its two screws (Fig. 12). Replace the grease filters. Fig. 12...
  • Page 9: Using The Hood

    Using the hood Using the hood Important to know The hood has one variable speed motor. For the best performance, we recommend using the low If the hood is run at the same time as a burner speeds in normal conditions and the high or fireplace that depend on ambient air (for speeds in particular cases of strong odour and example gas, Diesel, coal or wood heaters,...
  • Page 10: Carbon Filter Saturation Led

    Carbon filter saturation led Correct ventilation The LED marked C indicates carbon filter needs To have the cooker hood working correctly the to be replaced. windows in the kitchen should be closed. In stead This must be done after approximately 160 a window in an adjacent room should be open.
  • Page 11: If The Hood Does Not Function

    If the hood does not function Before you make contact to service Check that the power plug is connected to the wall power outlet and that no fuse is blown. Do not do any operations that can cause hazard or damage to the product.
  • Page 12: Technical Data

    Technical data Model EFC 009 X Capacity Intensive 609 m 225 m full speed 483 m low speed 246 m Dimension Height 752 - 930 mm Width 1000 mm Depth 700 mm Light (energy saving lamp) 2 x PL 9 W...