Figure 8 details the dimensions of the M620 module.
Xa
197.92mm
The weight of a maximum-configured M620 blade server is 7.0 kg (15.4 lb).
For the most up-to-date information on the M620 environmental specifications, see the
PowerEdge M620 System Owner's Manual
Support.Dell.com/Manuals. additional information about environmental measurements for specific
system configurations, see Dell.com/environmental_datasheets.
Table 23 details the environmental specifications for the M620.
Temperature and humidity
Continuous
operation
PowerEdge M620 Technical Guide
39
Xb
Y
192.3mm
50.35mm
and the
10°C to 35°C at 10% to 80% relative humidity (RH), with 26°C max dew
point. De-rate maximum allowable dry bulb temperature at 1°C per 300m
above 900m (1°F per 550 ft).
When using the PowerEdge M620 with internal GPU card(s), the continuous
operation range is 10°C to 30°C at 10% to 80% RH, with 26 °C max dew
point.
Zb
(handle
(handle open)
closed)
544.32mm