Check for misalignment and seizure of moving
parts, breakage of parts and any other conditions
that may affect its operation. Have damaged
guards or other defective parts repaired or
replaced as instructed. Do not use the tool if the
switch is defective. Have the switch replaced by
an authorized D
WALT repair agent.
E
20 Have your tool repaired by an authorized
D
WALT repair agent
E
This Power Tool is in accordance with the
relevant safety regulations. To avoid danger,
electric appliances must only be repaired by
qualified technicians.
Additional safety rules for cutters
• Always use cutters with a shank diameter
corresponding to the size of the collet installed
in your tool.
• Always use cutters suitable for a speed of
30.000 min
-1
and marked accordingly.
• Never use cutters with a diameter exceeding the
maximum diameter indicated in the technical data.

Package contents

The package contains:
1 Router
1 Parallel fence with fine adjustment and guide rods
1 Spanner # 22
1 Dust extraction adapter
1 Guide bush
1 Instruction manual
1 Exploded drawing
• Check for damage to the tool, parts or
accessories which may have occurred during
transport.
• Take the time to thoroughly read and understand
this manual prior to operation.
Description (fig. A)
Your D
WALT high performance Router has been
E
designed for professional heavy duty routing of
wood, wood products and plastics.
1 Lock-on button
2 Speed control dial
3 Collet nut
4 Spindle lock
5 Parallel fence locking bolt
6 Guide rods for parallel fence
17
7 Threaded spindle
8 Stop
9 Knurled nut
10 Grip
11 Handwheel
12 Measuring lens
13 Scale
14 Plunge lock
15 Clamping screw
16 Depth stop
17 Fine adjuster for depth stop
18 Fine adjuster for parallel fence
19 Parallel fence
20 Revolver depth stop
21 Router base
22 Baseplate extension
23 Guiding knob

Electrical safety

The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
WALT tool is double insulated
E
in accordance with EN 50144;
therefore no earth wire is required.

Mains plug replacement

(U.K. & Ireland only)
• Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorized
D
WALT repair agent or a qualified electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be marked
at the connection points of most good quality
plugs. Attach the wires to their respective points
in the plug (see below). Brown is for Live (L) (2)
and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminal screws.