1o InstaL! Ventilation
Installation of a suitable ventilation system (i.e.; ventilation hood)
above this range is strongly recommended.
For most kitchens
with a wall mounted hood, a certified hood rating of not less than
350 CFM is recommended. Bosch hoods rated at 350 CFMor more
when operated on high meet the above requirement
and are
recommended for this purpose. The range hood must be installed
according to instructions furnished with the hood.
2, Prepare
Cabinets
(See Figure
1)
This unit can be installed near adjacent walls and projecting
surfaces constructed of combustible materials. There must be a
minimum clearance of 30 inches between the top of the cooking
surface and the bottom of an unprotected wood or metal cabinet;
or 24 inches when bottom of wood or metal cabinet is protected
by not less than 1/4" of flame retardant material covered with
not less than No. 28 MSG sheet metal, 0.015 inch stainless steel
or 0.024 inch aluminum or copper, Zero clearance from unit walls
to adjacent vertical combustible walls is permitted on rear, right
and left walls.
Clearance from range top to adjacent vertical
walls must be at least 4".
Seal any openings in the wall behind the appliance and in the
floor below the appliance.
Forthe cabinets over the cooking surface and the adjacent cabinets,
the maximum cabinet depth from back wall is 13 inches.
The gas supply line and electrical outlet must be within the spaces
indicated in Figure 2. The gas shutoff valve must also be accessible
without moving the range.
Instructions
were determined using Standard American base
cabinets measuring 36" high x 24" deep. If nonstandard cabinets
are used, care should be taken to alter dimensions accordingly,
NOTIC£: Some cabinet finishes cannot survive the temperatures
allowed by UL and! or CSA, particularly self-cleaning ovens; the
cabinets may discolor or stain, This is most noticeable with
laminated cabinets,
Q
30"
Minimum
Centered
!
30'
P1in,
No Clearance
to Cabin
Wall
Required
O
18'
4"
P1in,
ure 1: Cabinet Preparation
Place Gas Supp}y
Line and
Electrical
Outlet
Here
Figure 2: Gas Supply Line and Electrical Outlet Placement
3, ]InstaL!
Anti-Tip
Bracket
1. Adjust height of range and level by rotating the
adjustable leg supports on the bottom of the range,
using 1-1/4" wrench.
Z
Measure to locate bracket position as shown in Figure 3.
3.
Secure bracket with 2 screws adequate for mounting
surface, not included (i.e.; for wood floor use wood screws
for concrete floor use concrete anchors and screws0.
Figure 3
Backwall
Cabinet Sidewall
Flush
\
Anti-Tip Device
Page 4