Fix Duct to transition
and seal with tape.
For both installation
method:
12.Wiring the HOOD:
WARNING
Electrical Shock Hazard
Turn off power at the service
panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit
required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN
ELECTRICAL JUNCTION BOX WITH 3
WIRES, ONE OF WHICH (GREEN/YELLOW)
SERVESTO GROUND THE APPLIANCE. TO
PROTECT YOU AGAINST ELECTRIC SHOCK,
THE GREEN AND YELLOW WIRE MUST BE
CONNECTED TO THE GROUNDING WIRE IN
YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST
UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or
electrical shock.
Remove the j-box
cover as shown
in
Figure 7 .
If not already done, install 1/2"conduit
connector
in j-box.
Run black, white, and green wires (#14
AWG) according to the National Electrical
Code or CSA Standards and local codes and
ordinances.
Connect black, white, and green wires from
power supply to black, white, and green/
yellow wires in j-box respectively.
CIosej-boxcover.
Final installation
steps
13. Install grease filters as described in the Care &
Use section of this manual.
Turn power on at service panel.
Check operation
of the hood.