Advance Planning
ADVANCE PLANNING
Ductwork
Planning
• This hood is equipped for 8" round ductwork.
• Determine the exact locution of the vent hood,
• Plan the route for venting exhaust to the outdoors,
This hood is not designed for a recirculating
venting operation,
• Use the shortest and straightest
duct route
possible, For satisfactory
performance,
duct run
should not exceed 100 ft, equivalent
length for any
duct configurations,
• Refer to "Duct Fittings" chart to compute
the
maximum
permissible
length for duct runs to
the outdoors,
• Use rigid metal ductwork
only,
• Install u wall or roof cap with damper at the
exterior opening. Order the cap and any transitions
needed in advance.
Wall and Ceiling Framing for Adequate
Support
This vent hood is heavy and the cabinet structure
needs to support the weight of the loaded insert
sleeve. Adequate structural
support must be
provided in all types of installations.
• Installation will be easier if the vent hood is
installed before the cooktop is installed,
Custom Cabinet Frame Planning
• The custom-built
canopy should be sized to
accommodate
the hood insert, and ducting
dimensions
in the bottom of cabinet should be
26" W bg !3-3/!6"
D for the 30" and 36" models
and 38-3/4" W by !3-3/!6"
D for the 48" models.
Remote Mounting
of the Control (Wired}
• The control can be remotely
mounted on the wall
or the countertop.
• It is recommended
that you use a professional
installer for the countertop
cutout.
• It is recommended
that the cutout in a granite
countertop
or other hard surface be made before
the countertop
is installed.
• The cutout needs to be made at least 6 inches
from the edges of the countertop.
• If mounting in the countertop
above a drawer,
consideration
must be given to the depth of the
control mounting
assembly.
• A 30 ft. wire cord is provided. Careful consideration
must be given to the location of the remotely
mounted control.
• It is recommended
that the a-wire cord be routed
through
!" conduit between the insert sleeve and
the remote mounting
location.
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING:
FOR PERSONAL SAFETY,THIS APPLIANCE
MUST BE PROPERLYGROUNDED.
AVERTISSEMENT :POUR
DES RAISONS DE SECURITE, CET APPAREIL
DOlT ETRE CORRECTEMENT HIS P, LA TERRE.
Remove house fuse or open circuit breaker before
beginning
installation,
Do not use an extension
cord or adapter
plug with
this appliance,
Follow National electrical
codes or
prevailing
local codes and ordinances.
Electrical
Supply
This vent hood must be supplied with 120V, 60Hz,
and connected
to an individual, properly grounded
branch circuit, and protected
bg a 15 or 20 amp
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements,
call a licensed electrician
before
proceeding.
• Route house wiring as close to the installation
location as possible, in the ceiling or back wall,
• Connect the hood wiring to the house wiring in
accordance
with local codes.
• House wiring must extend to 45" minimum
from
bottom of cabinet in order to make connection
to
hood wiring.
Grounding
Instructions
The grounding
conductor
must be connected
to
a grounded
metal, permanent
wiring system, or an
equipment-grounding
terminal
or lead on the hood.
WARNING:
The improper
connection
of the equipment-grounding
conductor
can result in a risk of electric
shock. Check with a qualified electrician
or service
representative
if you are in doubt whether
the
appliance
is properly
grounded.
AVERTISSEMENT :
Le mauvais
branchement
du fil de raise
la terre peut causer un choc @lectrique.
En cas de doute, consultez un @lectricien qualifi@
ou un technicien
pour d6terminer
si I'appareil est
la terre,

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monogram zvc48lssMonogram zvc30lssMonogram zvc36lss

Table of Contents