Ductwork, Wiring Locations - GE ZVC42L1SS Installation Instructions Manual

Custom hood inserts
Table of Contents

Advertisement

Available languages

Available languages

Wall Installation
Preparation
DUCTWORK, WiRiNG
LOCATIONS
Determine the exact location of the insert
sleeve. Hark the exact centerline location.
The ceiling structure must be capable of
supporting the weight of the insert sleeve
(approximately
100 pounds), the canopy
itself, any mounting hardware and any
inadvertent user contact loads.
, Measure from the top of the cooking
surface to the bottom edge of the insert
sleeve. Add insert sleeve installation height.
Mark that location.
, Use a level to draw a straight horizontal
pencil line on the wall.
NOTE: House duct should drop to 11-1/2"
above bottom
edge of insert sleeve.
Location of house duct is important
because it must align with vent of damper
plate assembly.
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
, Use a level to draw a centerline straight up
to the ceiling.
, On the ceiling, measure 5-1/2" from the
back wall to the centerline of an
8-1/2" hole.
Rear Wall Ducting: (See important note.)
If ductwork will vent to the rear:
, Use a level to draw a centerline straight
up to the ceiling.
, Measure at least 22-1/2" above the pencil
line that indicates the bottom installation
height, to the centerline of an 8-1/2" dia.
duct hole. (Hole may be elongated for duct
elbow.)
5-1/2" from
rear wall to
centerline
22-1/2"above
pencilline
indicating
bottomof hood
4" liner height
*30" Minimum
required
*36" Maximum
recommended
installation
height from
cooking surface
36" from
floor to
countertop
I
Side view
t
above
""
""
22-1/2
pencilline
////_
?_--r--:
_\\\\
indicating iod l_J_
)1 -1/2"
_'_]1
bottomof h
1 -1/2
4" liner height
*30" Minimum
required
*36" Maximum
recommended
installation
height from
cooking surface
Y
36" from
/
floor to
|
/
countertopL_l
Front view
Illustrations
not to scale
*Always refer to the cooktop or range installation
instructions
for product-specific
clearances.
HOUSE WIRING LOCATION:
, The junction box is located inside the top
left side of the hood.
IMPORTANT NOTE: If you are planning to vent through
the rear
wall, and the ceiling height is 8 ft., the maximum
installation
height is 33" above the cooking surface.
, Wiring should enter the back wall at
least 15" above the bottom of the insert
sleeve, and within 6" of the left side of the
centerline.
13

Advertisement

Table of Contents
loading

Table of Contents