lation instructions
ectrical Connections
ATTENTION iNSTALLER
All electric wall ovens must be hard wired
(direct wired) into an approved junction
box. A plug and receptacle
is NOT permitted
on these products.
DO NOT shorten the flexible
conduit.
The conduit strain relief clamp must be
securely
attached
to the junction
box
and the flexible
conduit
must be securely
attached
to the clamp, if the flexible
conduit will not fit within the clamp, do not
install the oven until a clamp of the proper
size is obtained.
NOTE TO ELECTRiCiAN:
The 3 power
leads supplied
with this appliance
are
UL recognized
for connection
to heavier
gauge household
wiring. The insulation
of these 3 leads is rated at temperatures
much
higher
than the temperature
rating
of household
wiring,
The current
carrying
capacity
of the conductor
is governed
by the wire gauge
and the temperature
rating
of the insulation
around
the wire.
WARNING: =mproper
connection
of aluminum
house
wiring to copper
leads can
result in an electrical
hazard or fire.
Use only connectors
designed
for
joining
copper to aluminum
and follow
the manufacturer's
recommended
procedure
closely.
Turn off the circuit breaker or remove
fuses to the oven branch circuit.
Conduit
With the oven supported
on a table
or platform
in front of the cabinet
opening,
connect
the flexible
conduit
to the electrical
junction
box as shown
below. Position the conduit
in such a
manner that it will lie on top of the
oven in a natural loop when the oven
is installed.
You will need to purchase
an appropriate
strain relief clamp to
complete
the connection
of the conduit
to the junction
box.
Junction
Box
Location
\
Place
oven
on
a
support
to assist ir
connecting
conduit
Lj
Strain Relief Clamp
(not included)
must be used at
Junction
Box