Frigidaire FPGC3087MSA Installation Instructions Manual
Frigidaire FPGC3087MSA Installation Instructions Manual

Frigidaire FPGC3087MSA Installation Instructions Manual

30" gas cooktop

Advertisement

Quick Links

iNSTALLATION
AND SERVICE
MUST BE PERFORMED
BY A
QUALIFIED
iNSTALLER.
iMPORTANT:
SAVE FOR LOCAL ELECTRICAL
iNSPECTOR'S
USE.
READ AND SAVE THESE iNSTRUCTIONS
FOR FUTURE REFERENCE.
if the information
in this
manual
is not followed
exactly, a fire or explosion
may result causing
property
damage,
personal injury or death.
FOR YOUR SAFETY:
m
Do not store or use gasoline
or other flammable
vapors
and
liquids in the vicinity
of this or any other
appliance.
WHAT TO DO iF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
immediately
call your gas supplier from a neighbor's
phone.
Follow the gas supplier's instructions.
if you cannot reach your gas supplier, call the fire department.
=
installation
and service
must be performed
by a qualified
installer,
service agency
or the gas supplier.
Appliances
installed
in the state of
Massachusetts:
This Appliance
can only
be installed in the state
of Massachusetts
by a
Massachusetts
licensed
plumber or gas fitter.
This appliance must be
installed with a three (3)
foot / 36 in. long flexible
gas connector. A"T"
handle type manual gas
valve must be installed
in the gas supply line to
this appliance.
30" Min. *
(76.2
cm)
JA
C
Gas Cooktop
Dimensions
Gas Cooktop
Cutout
Dimensions
Figure 1
30"
Cookto
28 1/=
19 1/8
All dimensions are stated in inches and (cm).
8
Dimension H includes a 5" (12.7 cm) space underneath the cooktop for connection to gas
supply line,
NOTE: Wiring
diagrams
for this cooktop
are enclosed
in this booklet
Printed in Canada
318205454 (1302) Rev, B
English - pages 1-9
Wiring Diagram 10

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FPGC3087MSA

  • Page 1 iNSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED iNSTALLER. iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE. READ AND SAVE THESE iNSTRUCTIONS FOR FUTURE REFERENCE. Appliances installed if the information in this manual is not followed in the state of exactly, a fire or explosion may result causing property...
  • Page 2: Important Notes To The Installer

    important Notes to the Installer . Air curtain or other overhead hoods, which 1. Read all instructions contained in these operate by blowing a downward air flow on to a range, shall not be used in conjunction installation instructions before installing with gas ranges other...
  • Page 3 30" (76.2 cm) Min. Clearance Between the Top of the Cooking Platform _;_i Unpr°tected 13" (33 cm) Max. Depth For Cabinet Installed dne_rMetal Above Cooktop. 2 ½" (6.4 cm) Minimum Clearance Distance Between Rear Edge of Cutout and 18" Min. Nearest Combustible (45.7 cm) Surface Above Countertop.
  • Page 4 Typical Under Counter Installation of an Electric Built-in Oven with a Cooktop Mounted Above All mounting hardware must be used to Side filler panels are necessary to isolate the unit from adjoining secure the built-in oven to cabinets. Panel height should the cabinets.
  • Page 5: Gas Cooktop

    Typical Gas Cooktop Installation Over an Electric Built-in Oven Installed Under the Counter FRONT VIEW 1 8" _ --- (45.7 cm) Max. GAS COOKTOP Approx..6½" Manifold Pipe-__ (16.5 c Flexible Connector Flare Union " I \,_1_- Z............ _=_1__ _Flare Union WALL OVEN CABINET...
  • Page 6: Installation

    1. Wall Outlet Location Once the cooktop is installed in the counter opening, you must clamp the unit down as shown. To clamp down, insert an angle bracket into the 12" slot on each side of the unit as shown. Run thumb '_...(30.5 screw...
  • Page 7 5. Install Pressure Regulator The supply line must be equipped with an approved manual shutoff valve. This valve should Install the pressure regulator with the arrow on the be located in the same room as the cooktop regulator pointing up toward the unit in a position and should be in a location...
  • Page 8: Electrical Requirements

    6. Electrical Requirements 7. Check Operation 120 volt, 60 Hertz, properly grounded branch Refer to the Use and Care Guide packaged with circuit protected by a 15 amp circuit breaker the cooktop for operating instructions and for care time delay fuse. Do not use an extension cord and cleaning of your cooktop.
  • Page 9 4. Adjust the "LOW" setting for regular 5.Adjust the "LOW" setting of the dual burner surface valve (Figure 10) (some models): surface burner valves (Figure Note: On the dual valve the low setting of each a. Push in and turn control to LITE until burner portion should...
  • Page 10 BURNER IGNITER QUEMADOR ENCENOIDO SUPERIOR BOOGIE O'AI IUMAGE BRUI , ,,, ,, ,, BURNER IGNITER INTERRUPTOR ENCENDtDO QUEMADOR ENCENDIDO SUPERIOR IGNITER INTRRUPTEUR SWITCH ALLUMEUR BOUGIE D'ALLUMAGE-BRULEUR BK-1 , ',, ,, ,, BURNER IGNITER IN[ERRUPTOR ENCBNDtDO OUEMADBR BNCENDIDO SUPERIOR IGNITER INTRRUPTEUR SWITCH A[tGMEUR BK-I_...

Table of Contents