Frigidaire FGF312ASA Installation Instructions Manual

30" gas range with electric ignition or standing pilot
Hide thumbs Also See for FGF312ASA:

Advertisement

Quick Links

INSTALLATION
AND SERVICE
MUST
BE PERFORMED
BY A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE
FOR LOCAL
ELECTRICAL
INSPECTOR'S
USE.
READ
AND SAVE
THESE
INSTRUCTIONS
FOR FUTURE
REFERENCE.
1_
If the information in this manual is not followed
exactly, a fire or explosion
may result causing
property
damage, personal injury or death.
FOR YOUR SAFETY:
--
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
--
WHATTO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone
in your building.
• Immediately
call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire
department.
--
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Refer to your serial plate for
applicable agency certification
ALL RANGES
CAN TIP.
INJURY TO
PERSONS
COULD
RESULT.
INSTALL
ANTI-TIP
DEVICE
PACKED
WITH RANGE.
SEE
INSTALLATION
INSTRUCTXDNS.
RANGE
1
\
TL
DoorOpen _
29
7/8"'_ -_-_>
Wall on Either
Side of Range.
Above 36 _
Height.
m
36"
Minimum
SIDE
VIEW
Minimumto
<-13"-1
Cabinets
on
Maximum
Depth
forCabinets
Above Range Top.
0' Clearance Below Cooking
Top and at Rear of Range.
Clearances
and Dimensions
1.
Location--Check
location where the ranae will be
installed. Check for proper electrical and gas supply,
and the stability of the floor.
2.
Dimensions that ere shown must be used_ Given
dimensions provide minimum clearance. Contact
surface must be solid and level.
Important
Notes to the Installer
1,
Read all instructions contained in these installation
instructionsbefore installing range,
2,
Remove all packing matedal fromtheoven compartments
before connecting the gas and electrical supply to the
range.
3,
Observe all governingcodes and ordinances.
4,
Be sure to leave these instructionswith the consumer,
Important Note to the Consumer: Keep these instructions
with your owner's guide for future reference.
EspaSol - Pages 11-20
P/N 316259312
(0112)
1

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FGF312ASA

  • Page 1 INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this manual is not followed exactly, a fire or explosion may result causing property Refer to your serial plate for damage, personal injury or death.
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY teach them theproper, safe use of all appliances. Never leave the oven door open when the range is unattended. INSTRUCTIONS Do not store items of interest to children in the cabinets above the range. Children couldbe seriously Installation of this range must conform with local codes or, in burned climbing on the range to reach items.
  • Page 3: Before Starting

    Before Starting Locate the Bracket Using the Template- (Bracketmay be located on eitherthe leftor rightside ofthe range. Use Tools You Will Need the informationbelowto locate the bracket if template is For leveling legs and Anti-Tip Bracket: notavailable). Mark thefloororwall where leftor rightside ofthe range willbe located.
  • Page 4 C. Level and Position Range- Level range byadjusting the (4) leveling legswitha wrench.Note:A minimum clearance of 1/8" isrequiredbetweenthe bottomofthe rangeandthe levelinglegto allowroomfor thebracket. Use a spiritlevel tocheckyour adjustments. Sliderange backinto position. Visually check that rear leveling leg is inserted into and fully secured by the Anti-Tip Bracket by removinglower panelorstoragedrawer.
  • Page 5 Gas connection for electric ignition models Foran accurate pressure check have at least two (2) other top Manual Flare Flexible Flare Union Pressure burnersburning. Be sure the gas supply(inlet) pressure isat Shutoff Union Appliance Adaptor Regulator leastone inchabove specified rangemanifoldpressure.The gas supplypressure shouldnever be over 14"water column.
  • Page 6 Grounding Instructions knob to the LITE position. You willhear the igniter sparking. The power cord of this appliance is equipped with The surface burner should lightwhen gas is available to the top a 3Iprong (grounding) p lugwhichmateswitha standard 3-pronggrounding burner. Each burner should light within four (4) seconds in wall receptacle to minimize the possibilityof electric shock normal operation after air has been purged from supply lines.
  • Page 7: Oven Adjustments

    7. Air adjustment Operation of Oven Burners and The air shutter(adjustment)for each ofthe fourtop burnersis Oven Adjustments located at the open end of the venturitube and sets on the hood of the valve, 9a, Electric Ignition Burners Operation of electric ignitersshould be checked after range Should the air shutter need adjusting, rotate the air shutterto and supply line connectors have been carefully checked for allow more or less air into the burner tubes as needed.
  • Page 8 9b. Standing Pilot Oven Burner To lightthe oven pilot, proceed as follows: Turn the oven thermostatknob to OFF. Remove oven bottom, see step 10 for instructions on removing the oven bottom. Light the oven pilot with a match. The oven pilot should burn with a stable flame after a few seconds operation and should Waist-High Burner have a small flame visible only at the opening in the top of the...
  • Page 9: Gas Conversion

    Pressure Regulatorlocation 12. Make Sure Range is Level. Leveltherange byplacinga levelhorizontallyon anoven rack. Check diagonallyfrom frontto back, then level the range by Fro_ A_C_SS eitheradjustingtheleveling legsor byplacingshimsunderthe tn negu_ton Remc_e _ck Pan_l, corners of the range as needed. St_gl_n_v_ Dra_, for InSl_).
  • Page 10 lc. Convert the Pressure Regulator - Non-Self- Cleaning Standing Pilot Models Remove the cap from the pressure regulator. b. Remove the plunger fromthe cap. c. Turn the plunger with the enlarged end down for LP/ Propane use. Turn the plungerwiththesmall end downfor Natural gas use, (See illustrationbelow,) d.

Table of Contents